Anterior cruciate ligament (ACL) reconstruction with quadriceps tendon autograft and press-fit fixation using an anteromedial portal technique

BACKGROUND: This article describes an arthroscopic anterior cruciate ligament (ACL) reconstruction technique with a quadriceps tendon autograft using an anteromedial portal technique. METHODS: A 5 cm quadriceps tendon graft is harvested with an adjacent 2 cm bone block. The femoral tunnel is created...

Descripción completa

Detalles Bibliográficos
Autores principales: Akoto, Ralph, Hoeher, Juergen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3495203/
https://www.ncbi.nlm.nih.gov/pubmed/22925587
http://dx.doi.org/10.1186/1471-2474-13-161
_version_ 1782249466954252288
author Akoto, Ralph
Hoeher, Juergen
author_facet Akoto, Ralph
Hoeher, Juergen
author_sort Akoto, Ralph
collection PubMed
description BACKGROUND: This article describes an arthroscopic anterior cruciate ligament (ACL) reconstruction technique with a quadriceps tendon autograft using an anteromedial portal technique. METHODS: A 5 cm quadriceps tendon graft is harvested with an adjacent 2 cm bone block. The femoral tunnel is created through a low anteromedial portal in its anatomical position. The tibial tunnel is created with a hollow burr, thus acquiring a free cylindrical bone block. The graft is then passed through the tibial tunnel and the bone block, customized at its tip, is tapped into the femoral tunnel through the anteromedial portal to provide press-fit fixation. The graft is tensioned distally and sutures are tied over a bone bridge at the distal end of the tibial tunnel. From the cylindrical bone block harvested from the tibia the proximal end is customized and gently tapped next to the graft tissue into the tibial tunnel to assure press fitting of the graft in the tibial tunnel. The distal part of the tibial tunnel is filled up with the remaining bone. All patients were observed in a prospective fashion with subjective and objective evaluation after 6 weeks, 6 and 12 months. RESULTS: Thirty patients have been evaluated at a 12 months follow-up. The technique achieved in 96.7% normal or nearly normal results for the objective IKDC. The mean subjective IKDC score was 86.1 ± 15.8. In 96.7% the Tegner score was the same as before injury or decreased one category. A negative or 1+ Lachman test was achieved in all cases. Pivot-shift test was negative or (+) glide in 86.7%. The mean side-to-side difference elevated by instrumental laxity measurement was 1.6 ± 1.1 mm. Full ROM has been achieved in 92.3%. The mean single one-leg-hop index was 91.9 ± 8.0 at the follow-up. CONCLUSIONS: Potential advantages include minimum bone loss specifically on the femoral side and graft fixation without implants.
format Online
Article
Text
id pubmed-3495203
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-34952032012-11-12 Anterior cruciate ligament (ACL) reconstruction with quadriceps tendon autograft and press-fit fixation using an anteromedial portal technique Akoto, Ralph Hoeher, Juergen BMC Musculoskelet Disord Technical Advance BACKGROUND: This article describes an arthroscopic anterior cruciate ligament (ACL) reconstruction technique with a quadriceps tendon autograft using an anteromedial portal technique. METHODS: A 5 cm quadriceps tendon graft is harvested with an adjacent 2 cm bone block. The femoral tunnel is created through a low anteromedial portal in its anatomical position. The tibial tunnel is created with a hollow burr, thus acquiring a free cylindrical bone block. The graft is then passed through the tibial tunnel and the bone block, customized at its tip, is tapped into the femoral tunnel through the anteromedial portal to provide press-fit fixation. The graft is tensioned distally and sutures are tied over a bone bridge at the distal end of the tibial tunnel. From the cylindrical bone block harvested from the tibia the proximal end is customized and gently tapped next to the graft tissue into the tibial tunnel to assure press fitting of the graft in the tibial tunnel. The distal part of the tibial tunnel is filled up with the remaining bone. All patients were observed in a prospective fashion with subjective and objective evaluation after 6 weeks, 6 and 12 months. RESULTS: Thirty patients have been evaluated at a 12 months follow-up. The technique achieved in 96.7% normal or nearly normal results for the objective IKDC. The mean subjective IKDC score was 86.1 ± 15.8. In 96.7% the Tegner score was the same as before injury or decreased one category. A negative or 1+ Lachman test was achieved in all cases. Pivot-shift test was negative or (+) glide in 86.7%. The mean side-to-side difference elevated by instrumental laxity measurement was 1.6 ± 1.1 mm. Full ROM has been achieved in 92.3%. The mean single one-leg-hop index was 91.9 ± 8.0 at the follow-up. CONCLUSIONS: Potential advantages include minimum bone loss specifically on the femoral side and graft fixation without implants. BioMed Central 2012-08-27 /pmc/articles/PMC3495203/ /pubmed/22925587 http://dx.doi.org/10.1186/1471-2474-13-161 Text en Copyright ©2012 Akoto and Hoeher; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Advance
Akoto, Ralph
Hoeher, Juergen
Anterior cruciate ligament (ACL) reconstruction with quadriceps tendon autograft and press-fit fixation using an anteromedial portal technique
title Anterior cruciate ligament (ACL) reconstruction with quadriceps tendon autograft and press-fit fixation using an anteromedial portal technique
title_full Anterior cruciate ligament (ACL) reconstruction with quadriceps tendon autograft and press-fit fixation using an anteromedial portal technique
title_fullStr Anterior cruciate ligament (ACL) reconstruction with quadriceps tendon autograft and press-fit fixation using an anteromedial portal technique
title_full_unstemmed Anterior cruciate ligament (ACL) reconstruction with quadriceps tendon autograft and press-fit fixation using an anteromedial portal technique
title_short Anterior cruciate ligament (ACL) reconstruction with quadriceps tendon autograft and press-fit fixation using an anteromedial portal technique
title_sort anterior cruciate ligament (acl) reconstruction with quadriceps tendon autograft and press-fit fixation using an anteromedial portal technique
topic Technical Advance
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3495203/
https://www.ncbi.nlm.nih.gov/pubmed/22925587
http://dx.doi.org/10.1186/1471-2474-13-161
work_keys_str_mv AT akotoralph anteriorcruciateligamentaclreconstructionwithquadricepstendonautograftandpressfitfixationusingananteromedialportaltechnique
AT hoeherjuergen anteriorcruciateligamentaclreconstructionwithquadricepstendonautograftandpressfitfixationusingananteromedialportaltechnique