Cargando…

The development of whole blood titanium levels after instrumented spinal fusion – Is there a correlation between the number of fused segments and titanium levels?

BACKGROUND: Most modern spinal implants contain titanium and remain in the patient’s body permanently. Local and systemic effects such as tissue necrosis, osteolysis and malignant cell transformation caused by implants have been described. Increasing tissue concentration and whole blood levels of io...

Descripción completa

Detalles Bibliográficos
Autores principales: Ipach, Ingmar, Schäfer, Ralf, Mittag, Falk, Leichtle, Carmen, Wolf, Petra, Kluba, Torsten
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3495207/
https://www.ncbi.nlm.nih.gov/pubmed/22925526
http://dx.doi.org/10.1186/1471-2474-13-159
_version_ 1782249467858124800
author Ipach, Ingmar
Schäfer, Ralf
Mittag, Falk
Leichtle, Carmen
Wolf, Petra
Kluba, Torsten
author_facet Ipach, Ingmar
Schäfer, Ralf
Mittag, Falk
Leichtle, Carmen
Wolf, Petra
Kluba, Torsten
author_sort Ipach, Ingmar
collection PubMed
description BACKGROUND: Most modern spinal implants contain titanium and remain in the patient’s body permanently. Local and systemic effects such as tissue necrosis, osteolysis and malignant cell transformation caused by implants have been described. Increasing tissue concentration and whole blood levels of ions are necessary before a disease caused by a contaminant develops. The aim of the present study was the measurement of whole blood titanium levels and the evaluation of a possible correlation between these changes and the number of fused segments. METHODS: A prospective study was designed to determine changes in whole blood titanium levels after spinal fusion and to analyze the correlation to the number of pedicle screws, cross connectors and interbody devices implanted. Blood samples were taken preoperatively in group I (n = 15), on the first, second and 10(th) day postoperatively, as well as 3 and 12 months after surgery. Group II (n = 16) served as a control group of volunteers who did not have any metal implants in the body. Blood samples were taken once in this group. The number of screw-rod-connections and the length of the spinal fusion were determined using radiographic pictures. This study was checked and approved by the ethical committee of the University of Tuebingen. RESULTS: The mean age in group I was 47 ± 22 years (range 16 - 85 years). There were three male (20%) and twelve female (80%) patients. The median number of fused segments was 5 (range 1 to 11 segments). No statistically significant increase in the titanium level was seen 12 months after surgery (mean difference: -7.2 μg/l, 95% CI: -26.9 to 12.5 μg/l, p = 0.446). By observing the individual titanium levels, 4 out of 15 patients demonstrated an increase in titanium levels 12 months after surgery. No statistically significant correlation between fused segments (r = -0.188, p = 0.503) length of instrumentation (r = -0.329, p = 0.231), number of interbody devices (r = -0.202, p = 0.291) and increase of titanium levels over the observation period was seen. CONCLUSIONS: Instrumented spinal fusion does not lead to a statistically significant increase in whole blood titanium levels. There seems to be no correlation between the number of pedicle screws, cross connectors and interbody devices implanted and the increase of serum titanium levels.
format Online
Article
Text
id pubmed-3495207
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-34952072012-11-12 The development of whole blood titanium levels after instrumented spinal fusion – Is there a correlation between the number of fused segments and titanium levels? Ipach, Ingmar Schäfer, Ralf Mittag, Falk Leichtle, Carmen Wolf, Petra Kluba, Torsten BMC Musculoskelet Disord Research Article BACKGROUND: Most modern spinal implants contain titanium and remain in the patient’s body permanently. Local and systemic effects such as tissue necrosis, osteolysis and malignant cell transformation caused by implants have been described. Increasing tissue concentration and whole blood levels of ions are necessary before a disease caused by a contaminant develops. The aim of the present study was the measurement of whole blood titanium levels and the evaluation of a possible correlation between these changes and the number of fused segments. METHODS: A prospective study was designed to determine changes in whole blood titanium levels after spinal fusion and to analyze the correlation to the number of pedicle screws, cross connectors and interbody devices implanted. Blood samples were taken preoperatively in group I (n = 15), on the first, second and 10(th) day postoperatively, as well as 3 and 12 months after surgery. Group II (n = 16) served as a control group of volunteers who did not have any metal implants in the body. Blood samples were taken once in this group. The number of screw-rod-connections and the length of the spinal fusion were determined using radiographic pictures. This study was checked and approved by the ethical committee of the University of Tuebingen. RESULTS: The mean age in group I was 47 ± 22 years (range 16 - 85 years). There were three male (20%) and twelve female (80%) patients. The median number of fused segments was 5 (range 1 to 11 segments). No statistically significant increase in the titanium level was seen 12 months after surgery (mean difference: -7.2 μg/l, 95% CI: -26.9 to 12.5 μg/l, p = 0.446). By observing the individual titanium levels, 4 out of 15 patients demonstrated an increase in titanium levels 12 months after surgery. No statistically significant correlation between fused segments (r = -0.188, p = 0.503) length of instrumentation (r = -0.329, p = 0.231), number of interbody devices (r = -0.202, p = 0.291) and increase of titanium levels over the observation period was seen. CONCLUSIONS: Instrumented spinal fusion does not lead to a statistically significant increase in whole blood titanium levels. There seems to be no correlation between the number of pedicle screws, cross connectors and interbody devices implanted and the increase of serum titanium levels. BioMed Central 2012-08-27 /pmc/articles/PMC3495207/ /pubmed/22925526 http://dx.doi.org/10.1186/1471-2474-13-159 Text en Copyright ©2012 Ipach et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Ipach, Ingmar
Schäfer, Ralf
Mittag, Falk
Leichtle, Carmen
Wolf, Petra
Kluba, Torsten
The development of whole blood titanium levels after instrumented spinal fusion – Is there a correlation between the number of fused segments and titanium levels?
title The development of whole blood titanium levels after instrumented spinal fusion – Is there a correlation between the number of fused segments and titanium levels?
title_full The development of whole blood titanium levels after instrumented spinal fusion – Is there a correlation between the number of fused segments and titanium levels?
title_fullStr The development of whole blood titanium levels after instrumented spinal fusion – Is there a correlation between the number of fused segments and titanium levels?
title_full_unstemmed The development of whole blood titanium levels after instrumented spinal fusion – Is there a correlation between the number of fused segments and titanium levels?
title_short The development of whole blood titanium levels after instrumented spinal fusion – Is there a correlation between the number of fused segments and titanium levels?
title_sort development of whole blood titanium levels after instrumented spinal fusion – is there a correlation between the number of fused segments and titanium levels?
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3495207/
https://www.ncbi.nlm.nih.gov/pubmed/22925526
http://dx.doi.org/10.1186/1471-2474-13-159
work_keys_str_mv AT ipachingmar thedevelopmentofwholebloodtitaniumlevelsafterinstrumentedspinalfusionisthereacorrelationbetweenthenumberoffusedsegmentsandtitaniumlevels
AT schaferralf thedevelopmentofwholebloodtitaniumlevelsafterinstrumentedspinalfusionisthereacorrelationbetweenthenumberoffusedsegmentsandtitaniumlevels
AT mittagfalk thedevelopmentofwholebloodtitaniumlevelsafterinstrumentedspinalfusionisthereacorrelationbetweenthenumberoffusedsegmentsandtitaniumlevels
AT leichtlecarmen thedevelopmentofwholebloodtitaniumlevelsafterinstrumentedspinalfusionisthereacorrelationbetweenthenumberoffusedsegmentsandtitaniumlevels
AT wolfpetra thedevelopmentofwholebloodtitaniumlevelsafterinstrumentedspinalfusionisthereacorrelationbetweenthenumberoffusedsegmentsandtitaniumlevels
AT klubatorsten thedevelopmentofwholebloodtitaniumlevelsafterinstrumentedspinalfusionisthereacorrelationbetweenthenumberoffusedsegmentsandtitaniumlevels
AT ipachingmar developmentofwholebloodtitaniumlevelsafterinstrumentedspinalfusionisthereacorrelationbetweenthenumberoffusedsegmentsandtitaniumlevels
AT schaferralf developmentofwholebloodtitaniumlevelsafterinstrumentedspinalfusionisthereacorrelationbetweenthenumberoffusedsegmentsandtitaniumlevels
AT mittagfalk developmentofwholebloodtitaniumlevelsafterinstrumentedspinalfusionisthereacorrelationbetweenthenumberoffusedsegmentsandtitaniumlevels
AT leichtlecarmen developmentofwholebloodtitaniumlevelsafterinstrumentedspinalfusionisthereacorrelationbetweenthenumberoffusedsegmentsandtitaniumlevels
AT wolfpetra developmentofwholebloodtitaniumlevelsafterinstrumentedspinalfusionisthereacorrelationbetweenthenumberoffusedsegmentsandtitaniumlevels
AT klubatorsten developmentofwholebloodtitaniumlevelsafterinstrumentedspinalfusionisthereacorrelationbetweenthenumberoffusedsegmentsandtitaniumlevels