Cargando…
A closed-tube methylation-sensitive high resolution melting assay (MS-HRMA) for the semi-quantitative determination of CST6 promoter methylation in clinical samples
BACKGROUND: CST6 promoter is highly methylated in cancer, and its detection can provide important prognostic information in breast cancer patients. The aim of our study was to develop a Methylation-Sensitive High Resolution Melting Analysis (MS-HRMA) assay for the investigation of CST6 promoter meth...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3495665/ https://www.ncbi.nlm.nih.gov/pubmed/23088560 http://dx.doi.org/10.1186/1471-2407-12-486 |
_version_ | 1782249545002909696 |
---|---|
author | Dimitrakopoulos, Lampros Vorkas, Panagiotis A Georgoulias, Vasilis Lianidou, Evi S |
author_facet | Dimitrakopoulos, Lampros Vorkas, Panagiotis A Georgoulias, Vasilis Lianidou, Evi S |
author_sort | Dimitrakopoulos, Lampros |
collection | PubMed |
description | BACKGROUND: CST6 promoter is highly methylated in cancer, and its detection can provide important prognostic information in breast cancer patients. The aim of our study was to develop a Methylation-Sensitive High Resolution Melting Analysis (MS-HRMA) assay for the investigation of CST6 promoter methylation. METHODS: We designed primers that amplify both methylated and unmethylated CST6 sequences after sodium bisulfate (SB) treatment and used spiked control samples of fully methylated to unmethylated SB converted genomic DNA to optimize the assay. We first evaluated the assay by analyzing 36 samples (pilot training group) and further analyzed 80 FFPES from operable breast cancer patients (independent group). MS-HRMA assay results for all 116 samples were compared with Methylation-Specific PCR (MSP) and the results were comparable. RESULTS: The developed assay is highly specific and sensitive since it can detect the presence of 1% methylated CST6 sequence and provides additionally a semi-quantitative estimation of CST6 promoter methylation. CST6 promoter was methylated in 39/80 (48.75%) of FFPEs with methylation levels being very different among samples. MS-HRMA and MSP gave comparable results when all samples were analyzed by both assays. CONCLUSIONS: The developed MS-HRMA assay for CST6 promoter methylation is closed tube, highly sensitive, cost-effective, rapid and easy-to-perform. It gives comparable results to MSP in less time, while it offers the advantage of additionally providing an estimation of the level of methylation. |
format | Online Article Text |
id | pubmed-3495665 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-34956652012-11-13 A closed-tube methylation-sensitive high resolution melting assay (MS-HRMA) for the semi-quantitative determination of CST6 promoter methylation in clinical samples Dimitrakopoulos, Lampros Vorkas, Panagiotis A Georgoulias, Vasilis Lianidou, Evi S BMC Cancer Research Article BACKGROUND: CST6 promoter is highly methylated in cancer, and its detection can provide important prognostic information in breast cancer patients. The aim of our study was to develop a Methylation-Sensitive High Resolution Melting Analysis (MS-HRMA) assay for the investigation of CST6 promoter methylation. METHODS: We designed primers that amplify both methylated and unmethylated CST6 sequences after sodium bisulfate (SB) treatment and used spiked control samples of fully methylated to unmethylated SB converted genomic DNA to optimize the assay. We first evaluated the assay by analyzing 36 samples (pilot training group) and further analyzed 80 FFPES from operable breast cancer patients (independent group). MS-HRMA assay results for all 116 samples were compared with Methylation-Specific PCR (MSP) and the results were comparable. RESULTS: The developed assay is highly specific and sensitive since it can detect the presence of 1% methylated CST6 sequence and provides additionally a semi-quantitative estimation of CST6 promoter methylation. CST6 promoter was methylated in 39/80 (48.75%) of FFPEs with methylation levels being very different among samples. MS-HRMA and MSP gave comparable results when all samples were analyzed by both assays. CONCLUSIONS: The developed MS-HRMA assay for CST6 promoter methylation is closed tube, highly sensitive, cost-effective, rapid and easy-to-perform. It gives comparable results to MSP in less time, while it offers the advantage of additionally providing an estimation of the level of methylation. BioMed Central 2012-10-22 /pmc/articles/PMC3495665/ /pubmed/23088560 http://dx.doi.org/10.1186/1471-2407-12-486 Text en Copyright ©2012 Dimitrakopoulos et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Dimitrakopoulos, Lampros Vorkas, Panagiotis A Georgoulias, Vasilis Lianidou, Evi S A closed-tube methylation-sensitive high resolution melting assay (MS-HRMA) for the semi-quantitative determination of CST6 promoter methylation in clinical samples |
title | A closed-tube methylation-sensitive high resolution melting assay (MS-HRMA) for the semi-quantitative determination of CST6 promoter methylation in clinical samples |
title_full | A closed-tube methylation-sensitive high resolution melting assay (MS-HRMA) for the semi-quantitative determination of CST6 promoter methylation in clinical samples |
title_fullStr | A closed-tube methylation-sensitive high resolution melting assay (MS-HRMA) for the semi-quantitative determination of CST6 promoter methylation in clinical samples |
title_full_unstemmed | A closed-tube methylation-sensitive high resolution melting assay (MS-HRMA) for the semi-quantitative determination of CST6 promoter methylation in clinical samples |
title_short | A closed-tube methylation-sensitive high resolution melting assay (MS-HRMA) for the semi-quantitative determination of CST6 promoter methylation in clinical samples |
title_sort | closed-tube methylation-sensitive high resolution melting assay (ms-hrma) for the semi-quantitative determination of cst6 promoter methylation in clinical samples |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3495665/ https://www.ncbi.nlm.nih.gov/pubmed/23088560 http://dx.doi.org/10.1186/1471-2407-12-486 |
work_keys_str_mv | AT dimitrakopouloslampros aclosedtubemethylationsensitivehighresolutionmeltingassaymshrmaforthesemiquantitativedeterminationofcst6promotermethylationinclinicalsamples AT vorkaspanagiotisa aclosedtubemethylationsensitivehighresolutionmeltingassaymshrmaforthesemiquantitativedeterminationofcst6promotermethylationinclinicalsamples AT georgouliasvasilis aclosedtubemethylationsensitivehighresolutionmeltingassaymshrmaforthesemiquantitativedeterminationofcst6promotermethylationinclinicalsamples AT lianidouevis aclosedtubemethylationsensitivehighresolutionmeltingassaymshrmaforthesemiquantitativedeterminationofcst6promotermethylationinclinicalsamples AT dimitrakopouloslampros closedtubemethylationsensitivehighresolutionmeltingassaymshrmaforthesemiquantitativedeterminationofcst6promotermethylationinclinicalsamples AT vorkaspanagiotisa closedtubemethylationsensitivehighresolutionmeltingassaymshrmaforthesemiquantitativedeterminationofcst6promotermethylationinclinicalsamples AT georgouliasvasilis closedtubemethylationsensitivehighresolutionmeltingassaymshrmaforthesemiquantitativedeterminationofcst6promotermethylationinclinicalsamples AT lianidouevis closedtubemethylationsensitivehighresolutionmeltingassaymshrmaforthesemiquantitativedeterminationofcst6promotermethylationinclinicalsamples |