Cargando…
Myocardium at risk by magnetic resonance imaging: head-to-head comparison of T2-weighted imaging and contrast-enhanced steady-state free precession
AIMS: To determine the myocardial salvage index, the extent of infarction needs to be related to the myocardium at risk (MaR). Thus, the ability to assess both infarct size and MaR is of central clinical and scientific importance. The aim of the present study was to explore the relationship between...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3496404/ https://www.ncbi.nlm.nih.gov/pubmed/22645203 http://dx.doi.org/10.1093/ehjci/jes091 |
_version_ | 1782249622237872128 |
---|---|
author | Ubachs, Joey F.A. Sörensson, Peder Engblom, Henrik Carlsson, Marcus Jovinge, Stefan Pernow, John Arheden, Håkan |
author_facet | Ubachs, Joey F.A. Sörensson, Peder Engblom, Henrik Carlsson, Marcus Jovinge, Stefan Pernow, John Arheden, Håkan |
author_sort | Ubachs, Joey F.A. |
collection | PubMed |
description | AIMS: To determine the myocardial salvage index, the extent of infarction needs to be related to the myocardium at risk (MaR). Thus, the ability to assess both infarct size and MaR is of central clinical and scientific importance. The aim of the present study was to explore the relationship between T2-weighted cardiac magnetic resonance (CMR) and contrast-enhanced steady-state free precession (CE-SSFP) CMR for the determination of MaR in patients with acute myocardial infarction. METHODS AND RESULTS: Twenty-one prospectively included patients with first-time ST-elevation myocardial infarction underwent CMR 1 week after primary percutaneous coronary intervention. For the assessment of MaR, T2-weighted images were acquired before and CE-SSFP images were acquired after the injection of a gadolinium-based contrast agent. For the assessment of infarct size, late gadolinium enhancement images were acquired. The MaR by T2-weighted imaging and CE-SSFP was 29 ± 11 and 32 ± 12% of the left ventricle, respectively. Thus, the MaR with T2-weighted imaging was slightly smaller than that by CE-SSFP (−3.0 ± 4.0%; P < 0.01). There was a significant correlation between the two MaR measures (r(2)= 0.89, P < 0.01), independent of the time after contrast agent administration at which the CE-SSFP was commenced (2–8 min). CONCLUSION: There is a good agreement between the MaR assessed by T2-weighted imaging and that assessed by CE-SSFP in patients with reperfused acute myocardial infarction 1 week after the acute event. Thus, both methods can be used to determine MaR and myocardial salvage at this point in time. |
format | Online Article Text |
id | pubmed-3496404 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-34964042012-11-13 Myocardium at risk by magnetic resonance imaging: head-to-head comparison of T2-weighted imaging and contrast-enhanced steady-state free precession Ubachs, Joey F.A. Sörensson, Peder Engblom, Henrik Carlsson, Marcus Jovinge, Stefan Pernow, John Arheden, Håkan Eur Heart J Cardiovasc Imaging Original Papers AIMS: To determine the myocardial salvage index, the extent of infarction needs to be related to the myocardium at risk (MaR). Thus, the ability to assess both infarct size and MaR is of central clinical and scientific importance. The aim of the present study was to explore the relationship between T2-weighted cardiac magnetic resonance (CMR) and contrast-enhanced steady-state free precession (CE-SSFP) CMR for the determination of MaR in patients with acute myocardial infarction. METHODS AND RESULTS: Twenty-one prospectively included patients with first-time ST-elevation myocardial infarction underwent CMR 1 week after primary percutaneous coronary intervention. For the assessment of MaR, T2-weighted images were acquired before and CE-SSFP images were acquired after the injection of a gadolinium-based contrast agent. For the assessment of infarct size, late gadolinium enhancement images were acquired. The MaR by T2-weighted imaging and CE-SSFP was 29 ± 11 and 32 ± 12% of the left ventricle, respectively. Thus, the MaR with T2-weighted imaging was slightly smaller than that by CE-SSFP (−3.0 ± 4.0%; P < 0.01). There was a significant correlation between the two MaR measures (r(2)= 0.89, P < 0.01), independent of the time after contrast agent administration at which the CE-SSFP was commenced (2–8 min). CONCLUSION: There is a good agreement between the MaR assessed by T2-weighted imaging and that assessed by CE-SSFP in patients with reperfused acute myocardial infarction 1 week after the acute event. Thus, both methods can be used to determine MaR and myocardial salvage at this point in time. Oxford University Press 2012-12 2012-05-29 /pmc/articles/PMC3496404/ /pubmed/22645203 http://dx.doi.org/10.1093/ehjci/jes091 Text en Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2012. For permissions please email: journals.permissions@oup.com. http://creativecommons.org/licenses/by-nc/2.0/uk/ The online version of this article has been published under an open access model. Users are entitled to use, reproduce, disseminate, or display the open access version of this article for non-commercial purposes provided that the original authorship is properly and fully attributed; the Journal, Learned Society and Oxford University Press are attributed as the original place of publication with correct citation details given; if an article is subsequently reproduced or disseminated not in its entirety but only in part or as a derivative work this must be clearly indicated. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Original Papers Ubachs, Joey F.A. Sörensson, Peder Engblom, Henrik Carlsson, Marcus Jovinge, Stefan Pernow, John Arheden, Håkan Myocardium at risk by magnetic resonance imaging: head-to-head comparison of T2-weighted imaging and contrast-enhanced steady-state free precession |
title | Myocardium at risk by magnetic resonance imaging: head-to-head comparison of T2-weighted imaging and contrast-enhanced steady-state free precession |
title_full | Myocardium at risk by magnetic resonance imaging: head-to-head comparison of T2-weighted imaging and contrast-enhanced steady-state free precession |
title_fullStr | Myocardium at risk by magnetic resonance imaging: head-to-head comparison of T2-weighted imaging and contrast-enhanced steady-state free precession |
title_full_unstemmed | Myocardium at risk by magnetic resonance imaging: head-to-head comparison of T2-weighted imaging and contrast-enhanced steady-state free precession |
title_short | Myocardium at risk by magnetic resonance imaging: head-to-head comparison of T2-weighted imaging and contrast-enhanced steady-state free precession |
title_sort | myocardium at risk by magnetic resonance imaging: head-to-head comparison of t2-weighted imaging and contrast-enhanced steady-state free precession |
topic | Original Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3496404/ https://www.ncbi.nlm.nih.gov/pubmed/22645203 http://dx.doi.org/10.1093/ehjci/jes091 |
work_keys_str_mv | AT ubachsjoeyfa myocardiumatriskbymagneticresonanceimagingheadtoheadcomparisonoft2weightedimagingandcontrastenhancedsteadystatefreeprecession AT sorenssonpeder myocardiumatriskbymagneticresonanceimagingheadtoheadcomparisonoft2weightedimagingandcontrastenhancedsteadystatefreeprecession AT engblomhenrik myocardiumatriskbymagneticresonanceimagingheadtoheadcomparisonoft2weightedimagingandcontrastenhancedsteadystatefreeprecession AT carlssonmarcus myocardiumatriskbymagneticresonanceimagingheadtoheadcomparisonoft2weightedimagingandcontrastenhancedsteadystatefreeprecession AT jovingestefan myocardiumatriskbymagneticresonanceimagingheadtoheadcomparisonoft2weightedimagingandcontrastenhancedsteadystatefreeprecession AT pernowjohn myocardiumatriskbymagneticresonanceimagingheadtoheadcomparisonoft2weightedimagingandcontrastenhancedsteadystatefreeprecession AT arhedenhakan myocardiumatriskbymagneticresonanceimagingheadtoheadcomparisonoft2weightedimagingandcontrastenhancedsteadystatefreeprecession |