Cargando…

Clinical Utility of the Cryptococcal Antigen Lateral Flow Assay in a Diagnostic Mycology Laboratory

BACKGROUND: Cryptococcus neoformans causes life-threatening meningitis. A recently introduced lateral flow immunoassay (LFA) to detect cryptococcal antigen (CRAG) is reportedly more rapid and convenient than standard latex agglutination (LA), but has not yet been evaluated in a diagnostic laboratory...

Descripción completa

Detalles Bibliográficos
Autores principales: McMullan, Brendan J., Halliday, Catriona, Sorrell, Tania C., Judd, David, Sleiman, Sue, Marriott, Debbie, Olma, Tom, Chen, Sharon C-A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3498116/
https://www.ncbi.nlm.nih.gov/pubmed/23166705
http://dx.doi.org/10.1371/journal.pone.0049541
_version_ 1782249785072287744
author McMullan, Brendan J.
Halliday, Catriona
Sorrell, Tania C.
Judd, David
Sleiman, Sue
Marriott, Debbie
Olma, Tom
Chen, Sharon C-A.
author_facet McMullan, Brendan J.
Halliday, Catriona
Sorrell, Tania C.
Judd, David
Sleiman, Sue
Marriott, Debbie
Olma, Tom
Chen, Sharon C-A.
author_sort McMullan, Brendan J.
collection PubMed
description BACKGROUND: Cryptococcus neoformans causes life-threatening meningitis. A recently introduced lateral flow immunoassay (LFA) to detect cryptococcal antigen (CRAG) is reportedly more rapid and convenient than standard latex agglutination (LA), but has not yet been evaluated in a diagnostic laboratory setting. METHODS: One hundred and six serum, 42 cerebrospinal fluid (CSF), and 20 urine samples from 92 patients with known or suspected cryptococcosis were tested by LA and LFA, and titres were compared. Results were correlated with laboratory-confirmed cryptococcosis. Serial samples were tested in nine treated patients. RESULTS: Twenty-five of 92 patients had confirmed cryptococcosis; all sera (n = 56) from these patients were positive by LFA (sensitivity 100%, 95% confidence interval (CI) 93.6–100%) compared with 51/56 positive by LA (sensitivity 91.1%, 95% CI 80.7–96.1%). Fifty sera from 67 patients without cryptococcosis tested negative in both assays. While LA yielded more false negative results (5/56) this did not reach statistical significance (p = 0.063). Nine CSF samples from patients with cryptococcal meningitis yielded positive results using both assays while 17/18 urine samples from patients with cryptococcosis were positive by the LFA. The LFA detected CRAG in C. gattii infection (n = 4 patients). Agreement between titres obtained by both methods (n = 38 samples) was imperfect; correlation between log-transformed titres (r) was 0.84. Turn-around-time was 20 minutes for the LFA and 2 h for LA. The cost per qualitative sample was 18USD and 91 USD, respectively and per quantitative sample was 38USD and 144USD, respectively. CONCLUSIONS: Qualitative agreement between the LFA and LA assays performed on serum and CSF was good but agreement between titres was imperfect. Ease of performance of the LFA and the capacity for testing urine suggest it has a role in the routine laboratory as a rapid diagnostic test or point-of-care test.
format Online
Article
Text
id pubmed-3498116
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-34981162012-11-19 Clinical Utility of the Cryptococcal Antigen Lateral Flow Assay in a Diagnostic Mycology Laboratory McMullan, Brendan J. Halliday, Catriona Sorrell, Tania C. Judd, David Sleiman, Sue Marriott, Debbie Olma, Tom Chen, Sharon C-A. PLoS One Research Article BACKGROUND: Cryptococcus neoformans causes life-threatening meningitis. A recently introduced lateral flow immunoassay (LFA) to detect cryptococcal antigen (CRAG) is reportedly more rapid and convenient than standard latex agglutination (LA), but has not yet been evaluated in a diagnostic laboratory setting. METHODS: One hundred and six serum, 42 cerebrospinal fluid (CSF), and 20 urine samples from 92 patients with known or suspected cryptococcosis were tested by LA and LFA, and titres were compared. Results were correlated with laboratory-confirmed cryptococcosis. Serial samples were tested in nine treated patients. RESULTS: Twenty-five of 92 patients had confirmed cryptococcosis; all sera (n = 56) from these patients were positive by LFA (sensitivity 100%, 95% confidence interval (CI) 93.6–100%) compared with 51/56 positive by LA (sensitivity 91.1%, 95% CI 80.7–96.1%). Fifty sera from 67 patients without cryptococcosis tested negative in both assays. While LA yielded more false negative results (5/56) this did not reach statistical significance (p = 0.063). Nine CSF samples from patients with cryptococcal meningitis yielded positive results using both assays while 17/18 urine samples from patients with cryptococcosis were positive by the LFA. The LFA detected CRAG in C. gattii infection (n = 4 patients). Agreement between titres obtained by both methods (n = 38 samples) was imperfect; correlation between log-transformed titres (r) was 0.84. Turn-around-time was 20 minutes for the LFA and 2 h for LA. The cost per qualitative sample was 18USD and 91 USD, respectively and per quantitative sample was 38USD and 144USD, respectively. CONCLUSIONS: Qualitative agreement between the LFA and LA assays performed on serum and CSF was good but agreement between titres was imperfect. Ease of performance of the LFA and the capacity for testing urine suggest it has a role in the routine laboratory as a rapid diagnostic test or point-of-care test. Public Library of Science 2012-11-14 /pmc/articles/PMC3498116/ /pubmed/23166705 http://dx.doi.org/10.1371/journal.pone.0049541 Text en https://creativecommons.org/publicdomain/zero/1.0/ This is an open-access article distributed under the terms of the Creative Commons Public Domain declaration, which stipulates that, once placed in the public domain, this work may be freely reproduced, distributed, transmitted, modified, built upon, or otherwise used by anyone for any lawful purpose.
spellingShingle Research Article
McMullan, Brendan J.
Halliday, Catriona
Sorrell, Tania C.
Judd, David
Sleiman, Sue
Marriott, Debbie
Olma, Tom
Chen, Sharon C-A.
Clinical Utility of the Cryptococcal Antigen Lateral Flow Assay in a Diagnostic Mycology Laboratory
title Clinical Utility of the Cryptococcal Antigen Lateral Flow Assay in a Diagnostic Mycology Laboratory
title_full Clinical Utility of the Cryptococcal Antigen Lateral Flow Assay in a Diagnostic Mycology Laboratory
title_fullStr Clinical Utility of the Cryptococcal Antigen Lateral Flow Assay in a Diagnostic Mycology Laboratory
title_full_unstemmed Clinical Utility of the Cryptococcal Antigen Lateral Flow Assay in a Diagnostic Mycology Laboratory
title_short Clinical Utility of the Cryptococcal Antigen Lateral Flow Assay in a Diagnostic Mycology Laboratory
title_sort clinical utility of the cryptococcal antigen lateral flow assay in a diagnostic mycology laboratory
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3498116/
https://www.ncbi.nlm.nih.gov/pubmed/23166705
http://dx.doi.org/10.1371/journal.pone.0049541
work_keys_str_mv AT mcmullanbrendanj clinicalutilityofthecryptococcalantigenlateralflowassayinadiagnosticmycologylaboratory
AT hallidaycatriona clinicalutilityofthecryptococcalantigenlateralflowassayinadiagnosticmycologylaboratory
AT sorrelltaniac clinicalutilityofthecryptococcalantigenlateralflowassayinadiagnosticmycologylaboratory
AT judddavid clinicalutilityofthecryptococcalantigenlateralflowassayinadiagnosticmycologylaboratory
AT sleimansue clinicalutilityofthecryptococcalantigenlateralflowassayinadiagnosticmycologylaboratory
AT marriottdebbie clinicalutilityofthecryptococcalantigenlateralflowassayinadiagnosticmycologylaboratory
AT olmatom clinicalutilityofthecryptococcalantigenlateralflowassayinadiagnosticmycologylaboratory
AT chensharonca clinicalutilityofthecryptococcalantigenlateralflowassayinadiagnosticmycologylaboratory