Cargando…

Cardiac Protection by Preconditioning Is Generated via an Iron-Signal Created by Proteasomal Degradation of Iron Proteins

Ischemia associated injury of the myocardium is caused by oxidative damage during reperfusion. Myocardial protection by ischemic preconditioning (IPC) was shown to be mediated by a transient ‘iron-signal’ that leads to the accumulation of apoferritin and sequestration of reactive iron released durin...

Descripción completa

Detalles Bibliográficos
Autores principales: Bulvik, Baruch E., Berenshtein, Eduard, Meyron-Holtz, Esther G., Konijn, Abraham M., Chevion, Mordechai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3498359/
https://www.ncbi.nlm.nih.gov/pubmed/23155431
http://dx.doi.org/10.1371/journal.pone.0048947
_version_ 1782249832375648256
author Bulvik, Baruch E.
Berenshtein, Eduard
Meyron-Holtz, Esther G.
Konijn, Abraham M.
Chevion, Mordechai
author_facet Bulvik, Baruch E.
Berenshtein, Eduard
Meyron-Holtz, Esther G.
Konijn, Abraham M.
Chevion, Mordechai
author_sort Bulvik, Baruch E.
collection PubMed
description Ischemia associated injury of the myocardium is caused by oxidative damage during reperfusion. Myocardial protection by ischemic preconditioning (IPC) was shown to be mediated by a transient ‘iron-signal’ that leads to the accumulation of apoferritin and sequestration of reactive iron released during the ischemia. Here we identified the source of this ‘iron signal’ and evaluated its role in the mechanisms of cardiac protection by hypoxic preconditioning. Rat hearts were retrogradely perfused and the effect of proteasomal and lysosomal protease inhibitors on ferritin levels were measured. The iron-signal was abolished, ferritin levels were not increased and cardiac protection was diminished by inhibition of the proteasome prior to IPC. Similarly, double amounts of ferritin and better recovery after ex vivo ischemia-and-reperfusion (I/R) were found in hearts from in vivo hypoxia pre-conditioned animals. IPC followed by normoxic perfusion for 30 min (‘delay’) prior to I/R caused a reduced ferritin accumulation at the end of the ischemia phase and reduced protection. Full restoration of the IPC-mediated cardiac protection was achieved by employing lysosomal inhibitors during the ‘delay’. In conclusion, proteasomal protein degradation of iron-proteins causes the generation of the ‘iron-signal’ by IPC, ensuing de-novo apoferritin synthesis and thus, sequestering reactive iron. Lysosomal proteases are involved in subsequent ferritin breakdown as revealed by the use of specific pathway inhibitors during the ‘delay’. We suggest that proteasomal iron-protein degradation is a stress response causing an expeditious cytosolic iron release thus, altering iron homeostasis to protect the myocardium during I/R, while lysosomal ferritin degradation is part of housekeeping iron homeostasis.
format Online
Article
Text
id pubmed-3498359
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-34983592012-11-15 Cardiac Protection by Preconditioning Is Generated via an Iron-Signal Created by Proteasomal Degradation of Iron Proteins Bulvik, Baruch E. Berenshtein, Eduard Meyron-Holtz, Esther G. Konijn, Abraham M. Chevion, Mordechai PLoS One Research Article Ischemia associated injury of the myocardium is caused by oxidative damage during reperfusion. Myocardial protection by ischemic preconditioning (IPC) was shown to be mediated by a transient ‘iron-signal’ that leads to the accumulation of apoferritin and sequestration of reactive iron released during the ischemia. Here we identified the source of this ‘iron signal’ and evaluated its role in the mechanisms of cardiac protection by hypoxic preconditioning. Rat hearts were retrogradely perfused and the effect of proteasomal and lysosomal protease inhibitors on ferritin levels were measured. The iron-signal was abolished, ferritin levels were not increased and cardiac protection was diminished by inhibition of the proteasome prior to IPC. Similarly, double amounts of ferritin and better recovery after ex vivo ischemia-and-reperfusion (I/R) were found in hearts from in vivo hypoxia pre-conditioned animals. IPC followed by normoxic perfusion for 30 min (‘delay’) prior to I/R caused a reduced ferritin accumulation at the end of the ischemia phase and reduced protection. Full restoration of the IPC-mediated cardiac protection was achieved by employing lysosomal inhibitors during the ‘delay’. In conclusion, proteasomal protein degradation of iron-proteins causes the generation of the ‘iron-signal’ by IPC, ensuing de-novo apoferritin synthesis and thus, sequestering reactive iron. Lysosomal proteases are involved in subsequent ferritin breakdown as revealed by the use of specific pathway inhibitors during the ‘delay’. We suggest that proteasomal iron-protein degradation is a stress response causing an expeditious cytosolic iron release thus, altering iron homeostasis to protect the myocardium during I/R, while lysosomal ferritin degradation is part of housekeeping iron homeostasis. Public Library of Science 2012-11-14 /pmc/articles/PMC3498359/ /pubmed/23155431 http://dx.doi.org/10.1371/journal.pone.0048947 Text en © 2012 Bulvik et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Bulvik, Baruch E.
Berenshtein, Eduard
Meyron-Holtz, Esther G.
Konijn, Abraham M.
Chevion, Mordechai
Cardiac Protection by Preconditioning Is Generated via an Iron-Signal Created by Proteasomal Degradation of Iron Proteins
title Cardiac Protection by Preconditioning Is Generated via an Iron-Signal Created by Proteasomal Degradation of Iron Proteins
title_full Cardiac Protection by Preconditioning Is Generated via an Iron-Signal Created by Proteasomal Degradation of Iron Proteins
title_fullStr Cardiac Protection by Preconditioning Is Generated via an Iron-Signal Created by Proteasomal Degradation of Iron Proteins
title_full_unstemmed Cardiac Protection by Preconditioning Is Generated via an Iron-Signal Created by Proteasomal Degradation of Iron Proteins
title_short Cardiac Protection by Preconditioning Is Generated via an Iron-Signal Created by Proteasomal Degradation of Iron Proteins
title_sort cardiac protection by preconditioning is generated via an iron-signal created by proteasomal degradation of iron proteins
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3498359/
https://www.ncbi.nlm.nih.gov/pubmed/23155431
http://dx.doi.org/10.1371/journal.pone.0048947
work_keys_str_mv AT bulvikbaruche cardiacprotectionbypreconditioningisgeneratedviaanironsignalcreatedbyproteasomaldegradationofironproteins
AT berenshteineduard cardiacprotectionbypreconditioningisgeneratedviaanironsignalcreatedbyproteasomaldegradationofironproteins
AT meyronholtzestherg cardiacprotectionbypreconditioningisgeneratedviaanironsignalcreatedbyproteasomaldegradationofironproteins
AT konijnabrahamm cardiacprotectionbypreconditioningisgeneratedviaanironsignalcreatedbyproteasomaldegradationofironproteins
AT chevionmordechai cardiacprotectionbypreconditioningisgeneratedviaanironsignalcreatedbyproteasomaldegradationofironproteins