Cargando…
An open real-time tele-stethoscopy system
BACKGROUND: Acute respiratory infections are the leading cause of childhood mortality. The lack of physicians in rural areas of developing countries makes difficult their correct diagnosis and treatment. The staff of rural health facilities (health-care technicians) may not be qualified to distingui...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3499164/ https://www.ncbi.nlm.nih.gov/pubmed/22917062 http://dx.doi.org/10.1186/1475-925X-11-57 |
_version_ | 1782249908201324544 |
---|---|
author | Foche-Perez, Ignacio Ramirez-Payba, Rodolfo Hirigoyen-Emparanza, German Balducci-Gonzalez, Fernando Simo-Reigadas, Francisco-Javier Seoane-Pascual, Joaquin Corral-Peñafiel, Jaime Martinez-Fernandez, Andres |
author_facet | Foche-Perez, Ignacio Ramirez-Payba, Rodolfo Hirigoyen-Emparanza, German Balducci-Gonzalez, Fernando Simo-Reigadas, Francisco-Javier Seoane-Pascual, Joaquin Corral-Peñafiel, Jaime Martinez-Fernandez, Andres |
author_sort | Foche-Perez, Ignacio |
collection | PubMed |
description | BACKGROUND: Acute respiratory infections are the leading cause of childhood mortality. The lack of physicians in rural areas of developing countries makes difficult their correct diagnosis and treatment. The staff of rural health facilities (health-care technicians) may not be qualified to distinguish respiratory diseases by auscultation. For this reason, the goal of this project is the development of a tele-stethoscopy system that allows a physician to receive real-time cardio-respiratory sounds from a remote auscultation, as well as video images showing where the technician is placing the stethoscope on the patient’s body. METHODS: A real-time wireless stethoscopy system was designed. The initial requirements were: 1) The system must send audio and video synchronously over IP networks, not requiring an Internet connection; 2) It must preserve the quality of cardiorespiratory sounds, allowing to adapt the binaural pieces and the chestpiece of standard stethoscopes, and; 3) Cardiorespiratory sounds should be recordable at both sides of the communication. In order to verify the diagnostic capacity of the system, a clinical validation with eight specialists has been designed. In a preliminary test, twelve patients have been auscultated by all the physicians using the tele-stethoscopy system, versus a local auscultation using traditional stethoscope. The system must allow listen the cardiac (systolic and diastolic murmurs, gallop sound, arrhythmias) and respiratory (rhonchi, rales and crepitations, wheeze, diminished and bronchial breath sounds, pleural friction rub) sounds. RESULTS: The design, development and initial validation of the real-time wireless tele-stethoscopy system are described in detail. The system was conceived from scratch as open-source, low-cost and designed in such a way that many universities and small local companies in developing countries may manufacture it. Only free open-source software has been used in order to minimize manufacturing costs and look for alliances to support its improvement and adaptation. The microcontroller firmware code, the computer software code and the PCB schematics are available for free download in a subversion repository hosted in SourceForge. CONCLUSIONS: It has been shown that real-time tele-stethoscopy, together with a videoconference system that allows a remote specialist to oversee the auscultation, may be a very helpful tool in rural areas of developing countries. |
format | Online Article Text |
id | pubmed-3499164 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-34991642012-11-16 An open real-time tele-stethoscopy system Foche-Perez, Ignacio Ramirez-Payba, Rodolfo Hirigoyen-Emparanza, German Balducci-Gonzalez, Fernando Simo-Reigadas, Francisco-Javier Seoane-Pascual, Joaquin Corral-Peñafiel, Jaime Martinez-Fernandez, Andres Biomed Eng Online Research BACKGROUND: Acute respiratory infections are the leading cause of childhood mortality. The lack of physicians in rural areas of developing countries makes difficult their correct diagnosis and treatment. The staff of rural health facilities (health-care technicians) may not be qualified to distinguish respiratory diseases by auscultation. For this reason, the goal of this project is the development of a tele-stethoscopy system that allows a physician to receive real-time cardio-respiratory sounds from a remote auscultation, as well as video images showing where the technician is placing the stethoscope on the patient’s body. METHODS: A real-time wireless stethoscopy system was designed. The initial requirements were: 1) The system must send audio and video synchronously over IP networks, not requiring an Internet connection; 2) It must preserve the quality of cardiorespiratory sounds, allowing to adapt the binaural pieces and the chestpiece of standard stethoscopes, and; 3) Cardiorespiratory sounds should be recordable at both sides of the communication. In order to verify the diagnostic capacity of the system, a clinical validation with eight specialists has been designed. In a preliminary test, twelve patients have been auscultated by all the physicians using the tele-stethoscopy system, versus a local auscultation using traditional stethoscope. The system must allow listen the cardiac (systolic and diastolic murmurs, gallop sound, arrhythmias) and respiratory (rhonchi, rales and crepitations, wheeze, diminished and bronchial breath sounds, pleural friction rub) sounds. RESULTS: The design, development and initial validation of the real-time wireless tele-stethoscopy system are described in detail. The system was conceived from scratch as open-source, low-cost and designed in such a way that many universities and small local companies in developing countries may manufacture it. Only free open-source software has been used in order to minimize manufacturing costs and look for alliances to support its improvement and adaptation. The microcontroller firmware code, the computer software code and the PCB schematics are available for free download in a subversion repository hosted in SourceForge. CONCLUSIONS: It has been shown that real-time tele-stethoscopy, together with a videoconference system that allows a remote specialist to oversee the auscultation, may be a very helpful tool in rural areas of developing countries. BioMed Central 2012-08-23 /pmc/articles/PMC3499164/ /pubmed/22917062 http://dx.doi.org/10.1186/1475-925X-11-57 Text en Copyright ©2012 Foche-Perez et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Foche-Perez, Ignacio Ramirez-Payba, Rodolfo Hirigoyen-Emparanza, German Balducci-Gonzalez, Fernando Simo-Reigadas, Francisco-Javier Seoane-Pascual, Joaquin Corral-Peñafiel, Jaime Martinez-Fernandez, Andres An open real-time tele-stethoscopy system |
title | An open real-time tele-stethoscopy system |
title_full | An open real-time tele-stethoscopy system |
title_fullStr | An open real-time tele-stethoscopy system |
title_full_unstemmed | An open real-time tele-stethoscopy system |
title_short | An open real-time tele-stethoscopy system |
title_sort | open real-time tele-stethoscopy system |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3499164/ https://www.ncbi.nlm.nih.gov/pubmed/22917062 http://dx.doi.org/10.1186/1475-925X-11-57 |
work_keys_str_mv | AT focheperezignacio anopenrealtimetelestethoscopysystem AT ramirezpaybarodolfo anopenrealtimetelestethoscopysystem AT hirigoyenemparanzagerman anopenrealtimetelestethoscopysystem AT balduccigonzalezfernando anopenrealtimetelestethoscopysystem AT simoreigadasfranciscojavier anopenrealtimetelestethoscopysystem AT seoanepascualjoaquin anopenrealtimetelestethoscopysystem AT corralpenafieljaime anopenrealtimetelestethoscopysystem AT martinezfernandezandres anopenrealtimetelestethoscopysystem AT focheperezignacio openrealtimetelestethoscopysystem AT ramirezpaybarodolfo openrealtimetelestethoscopysystem AT hirigoyenemparanzagerman openrealtimetelestethoscopysystem AT balduccigonzalezfernando openrealtimetelestethoscopysystem AT simoreigadasfranciscojavier openrealtimetelestethoscopysystem AT seoanepascualjoaquin openrealtimetelestethoscopysystem AT corralpenafieljaime openrealtimetelestethoscopysystem AT martinezfernandezandres openrealtimetelestethoscopysystem |