Cargando…

Improvement of Intradialytic Hypotension in Diabetic Hemodialysis Patients Using Vitamin E-Bonded Polysulfone Membrane Dialyzers

Currently, there are no detailed reports on the effects of vitamin E-bonded polysulfone (PS) membrane dialyzers on intradialytic hypotension (IDH) in diabetic hemodialysis (HD) patients. This study was designed to evaluate changes in intradialytic systolic blood pressure (SBP) using “VPS-HA” vitamin...

Descripción completa

Detalles Bibliográficos
Autores principales: Koremoto, Masahide, Takahara, Noriko, Takahashi, Masahiro, Okada, Yasuhiro, Satoh, Kouhei, Kimura, Tomoyoshi, Hirai, Tomoyuki, Ebihara, Itaru, Nagasaku, Daisuke, Miyata, Shigeo, Maniwa, Shunji, Kouzuma, Takuji, Arimura, Tetsurou, Kamei, Junzou
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Blackwell Publishing Inc 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3500504/
https://www.ncbi.nlm.nih.gov/pubmed/22845774
http://dx.doi.org/10.1111/j.1525-1594.2012.01483.x
_version_ 1782250115103195136
author Koremoto, Masahide
Takahara, Noriko
Takahashi, Masahiro
Okada, Yasuhiro
Satoh, Kouhei
Kimura, Tomoyoshi
Hirai, Tomoyuki
Ebihara, Itaru
Nagasaku, Daisuke
Miyata, Shigeo
Maniwa, Shunji
Kouzuma, Takuji
Arimura, Tetsurou
Kamei, Junzou
author_facet Koremoto, Masahide
Takahara, Noriko
Takahashi, Masahiro
Okada, Yasuhiro
Satoh, Kouhei
Kimura, Tomoyoshi
Hirai, Tomoyuki
Ebihara, Itaru
Nagasaku, Daisuke
Miyata, Shigeo
Maniwa, Shunji
Kouzuma, Takuji
Arimura, Tetsurou
Kamei, Junzou
author_sort Koremoto, Masahide
collection PubMed
description Currently, there are no detailed reports on the effects of vitamin E-bonded polysulfone (PS) membrane dialyzers on intradialytic hypotension (IDH) in diabetic hemodialysis (HD) patients. This study was designed to evaluate changes in intradialytic systolic blood pressure (SBP) using “VPS-HA” vitamin E-bonded super high-flux PS membrane dialyzers. The subjects were 62 diabetic HD patients whose intradialytic SBP fell by more than 20%. Group A comprised patients who required vasopressors to be able to continue treatment or who had to discontinue therapy due to their lowest intradialytic SBP being observed at 210 min (28 patients). Group B comprised patients who showed no symptoms and required no vasopressors but showed a gradual reduction in blood pressure, with the lowest intradialytic SBP seen at the end of dialysis (34 patients). The primary outcome was defined as the lowest intradialytic SBP after 3 months using VPS-HA. Secondary outcomes included changes in the following: lowest intradialytic diastolic blood pressure, pulse pressure, pulse rate, plasma nitric oxide and peroxynitrite, serum albumin, and hemoglobin A1c. Group A's lowest intradialytic SBP had significantly improved at 3 months (128.0 ± 25.1 mm Hg vs. 117.1 ± 29.2 mm Hg; P = 0.017). Group B's lowest intradialytic SBP had significantly improved at 1 month (134.4 ± 13.2 mm Hg vs. 121.5 ± 25.8 mm Hg; P = 0.047) and 3 months (139.1 ± 20.9 mm Hg vs. 121.5 ± 25.8 mm Hg; P = 0.011). We conclude that VPS-HA may improve IDH in diabetic HD patients.
format Online
Article
Text
id pubmed-3500504
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Blackwell Publishing Inc
record_format MEDLINE/PubMed
spelling pubmed-35005042012-11-20 Improvement of Intradialytic Hypotension in Diabetic Hemodialysis Patients Using Vitamin E-Bonded Polysulfone Membrane Dialyzers Koremoto, Masahide Takahara, Noriko Takahashi, Masahiro Okada, Yasuhiro Satoh, Kouhei Kimura, Tomoyoshi Hirai, Tomoyuki Ebihara, Itaru Nagasaku, Daisuke Miyata, Shigeo Maniwa, Shunji Kouzuma, Takuji Arimura, Tetsurou Kamei, Junzou Artif Organs Main Text Articles Currently, there are no detailed reports on the effects of vitamin E-bonded polysulfone (PS) membrane dialyzers on intradialytic hypotension (IDH) in diabetic hemodialysis (HD) patients. This study was designed to evaluate changes in intradialytic systolic blood pressure (SBP) using “VPS-HA” vitamin E-bonded super high-flux PS membrane dialyzers. The subjects were 62 diabetic HD patients whose intradialytic SBP fell by more than 20%. Group A comprised patients who required vasopressors to be able to continue treatment or who had to discontinue therapy due to their lowest intradialytic SBP being observed at 210 min (28 patients). Group B comprised patients who showed no symptoms and required no vasopressors but showed a gradual reduction in blood pressure, with the lowest intradialytic SBP seen at the end of dialysis (34 patients). The primary outcome was defined as the lowest intradialytic SBP after 3 months using VPS-HA. Secondary outcomes included changes in the following: lowest intradialytic diastolic blood pressure, pulse pressure, pulse rate, plasma nitric oxide and peroxynitrite, serum albumin, and hemoglobin A1c. Group A's lowest intradialytic SBP had significantly improved at 3 months (128.0 ± 25.1 mm Hg vs. 117.1 ± 29.2 mm Hg; P = 0.017). Group B's lowest intradialytic SBP had significantly improved at 1 month (134.4 ± 13.2 mm Hg vs. 121.5 ± 25.8 mm Hg; P = 0.047) and 3 months (139.1 ± 20.9 mm Hg vs. 121.5 ± 25.8 mm Hg; P = 0.011). We conclude that VPS-HA may improve IDH in diabetic HD patients. Blackwell Publishing Inc 2012-10 /pmc/articles/PMC3500504/ /pubmed/22845774 http://dx.doi.org/10.1111/j.1525-1594.2012.01483.x Text en © 2012, Copyright the Authors. Artificial Organs © 2012, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc http://creativecommons.org/licenses/by/2.5/ Re-use of this article is permitted in accordance with the Creative Commons Deed, Attribution 2.5, which does not permit commercial exploitation.
spellingShingle Main Text Articles
Koremoto, Masahide
Takahara, Noriko
Takahashi, Masahiro
Okada, Yasuhiro
Satoh, Kouhei
Kimura, Tomoyoshi
Hirai, Tomoyuki
Ebihara, Itaru
Nagasaku, Daisuke
Miyata, Shigeo
Maniwa, Shunji
Kouzuma, Takuji
Arimura, Tetsurou
Kamei, Junzou
Improvement of Intradialytic Hypotension in Diabetic Hemodialysis Patients Using Vitamin E-Bonded Polysulfone Membrane Dialyzers
title Improvement of Intradialytic Hypotension in Diabetic Hemodialysis Patients Using Vitamin E-Bonded Polysulfone Membrane Dialyzers
title_full Improvement of Intradialytic Hypotension in Diabetic Hemodialysis Patients Using Vitamin E-Bonded Polysulfone Membrane Dialyzers
title_fullStr Improvement of Intradialytic Hypotension in Diabetic Hemodialysis Patients Using Vitamin E-Bonded Polysulfone Membrane Dialyzers
title_full_unstemmed Improvement of Intradialytic Hypotension in Diabetic Hemodialysis Patients Using Vitamin E-Bonded Polysulfone Membrane Dialyzers
title_short Improvement of Intradialytic Hypotension in Diabetic Hemodialysis Patients Using Vitamin E-Bonded Polysulfone Membrane Dialyzers
title_sort improvement of intradialytic hypotension in diabetic hemodialysis patients using vitamin e-bonded polysulfone membrane dialyzers
topic Main Text Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3500504/
https://www.ncbi.nlm.nih.gov/pubmed/22845774
http://dx.doi.org/10.1111/j.1525-1594.2012.01483.x
work_keys_str_mv AT koremotomasahide improvementofintradialytichypotensionindiabetichemodialysispatientsusingvitaminebondedpolysulfonemembranedialyzers
AT takaharanoriko improvementofintradialytichypotensionindiabetichemodialysispatientsusingvitaminebondedpolysulfonemembranedialyzers
AT takahashimasahiro improvementofintradialytichypotensionindiabetichemodialysispatientsusingvitaminebondedpolysulfonemembranedialyzers
AT okadayasuhiro improvementofintradialytichypotensionindiabetichemodialysispatientsusingvitaminebondedpolysulfonemembranedialyzers
AT satohkouhei improvementofintradialytichypotensionindiabetichemodialysispatientsusingvitaminebondedpolysulfonemembranedialyzers
AT kimuratomoyoshi improvementofintradialytichypotensionindiabetichemodialysispatientsusingvitaminebondedpolysulfonemembranedialyzers
AT hiraitomoyuki improvementofintradialytichypotensionindiabetichemodialysispatientsusingvitaminebondedpolysulfonemembranedialyzers
AT ebiharaitaru improvementofintradialytichypotensionindiabetichemodialysispatientsusingvitaminebondedpolysulfonemembranedialyzers
AT nagasakudaisuke improvementofintradialytichypotensionindiabetichemodialysispatientsusingvitaminebondedpolysulfonemembranedialyzers
AT miyatashigeo improvementofintradialytichypotensionindiabetichemodialysispatientsusingvitaminebondedpolysulfonemembranedialyzers
AT maniwashunji improvementofintradialytichypotensionindiabetichemodialysispatientsusingvitaminebondedpolysulfonemembranedialyzers
AT kouzumatakuji improvementofintradialytichypotensionindiabetichemodialysispatientsusingvitaminebondedpolysulfonemembranedialyzers
AT arimuratetsurou improvementofintradialytichypotensionindiabetichemodialysispatientsusingvitaminebondedpolysulfonemembranedialyzers
AT kameijunzou improvementofintradialytichypotensionindiabetichemodialysispatientsusingvitaminebondedpolysulfonemembranedialyzers