Cargando…
Automatic Reading of ANCA-Slides: Evaluation of the AKLIDES System
The ANCA consensus prescribes screening by indirect immunofluorescence on neutrophils. We evaluated the first automated ANCA-pattern recognition system. C-ANCA (n = 39) and P-ANCA (n = 40) samples were selected from patients with ANCA-associated vasculitis (AAV). Non-AAV controls included sera from...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3501831/ https://www.ncbi.nlm.nih.gov/pubmed/23193419 http://dx.doi.org/10.1155/2012/762874 |
_version_ | 1782250226602475520 |
---|---|
author | Damoiseaux, Jan Mallet, Kathleen Vaessen, Mia Austen, Jos Cohen Tervaert, Jan Willem |
author_facet | Damoiseaux, Jan Mallet, Kathleen Vaessen, Mia Austen, Jos Cohen Tervaert, Jan Willem |
author_sort | Damoiseaux, Jan |
collection | PubMed |
description | The ANCA consensus prescribes screening by indirect immunofluorescence on neutrophils. We evaluated the first automated ANCA-pattern recognition system. C-ANCA (n = 39) and P-ANCA (n = 40) samples were selected from patients with ANCA-associated vasculitis (AAV). Non-AAV controls included sera from healthy controls (n = 40), sera with possible interfering antibodies (n = 46), or miscellaneous ANCA reactivity (n = 31). ANCA slides were analysed by AKLIDES and routine fluorescence microscopy. The C-ANCA pattern was recognized by routine microscopy in 92% and 97% on ethanol- and formalin-fixed slides, respectively. AKLIDES reported C-ANCA in 74% and 95%, respectively. P-ANCA was recognized by routine microscopy on ethanol-fixed neutrophils in 90%, while AKLIDES reported P-ANCA in 80%. Typically, only 65% and 33% of these samples showed the expected C-ANCA on formalin-fixed neutrophils by routine microscopy and AKLIDES, respectively. A C- or P-ANCA pattern was observed on ethanol-fixed neutrophils in 28% and 23% of the controls by routine microscopy and AKLIDES, respectively. Only 5% of the controls revealed C-ANCA on formalin-fixed neutrophils by routine microscopy and AKLIDES. Altogether, automated ANCA-pattern recognition by AKLIDES is promising. Distinction of C- and P-ANCA is good, but sensitivity on ethanol-fixed neutrophils needs improvement. When optimized, pattern recognition software may play an important role in AAV diagnostics. |
format | Online Article Text |
id | pubmed-3501831 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-35018312012-11-28 Automatic Reading of ANCA-Slides: Evaluation of the AKLIDES System Damoiseaux, Jan Mallet, Kathleen Vaessen, Mia Austen, Jos Cohen Tervaert, Jan Willem Clin Dev Immunol Research Article The ANCA consensus prescribes screening by indirect immunofluorescence on neutrophils. We evaluated the first automated ANCA-pattern recognition system. C-ANCA (n = 39) and P-ANCA (n = 40) samples were selected from patients with ANCA-associated vasculitis (AAV). Non-AAV controls included sera from healthy controls (n = 40), sera with possible interfering antibodies (n = 46), or miscellaneous ANCA reactivity (n = 31). ANCA slides were analysed by AKLIDES and routine fluorescence microscopy. The C-ANCA pattern was recognized by routine microscopy in 92% and 97% on ethanol- and formalin-fixed slides, respectively. AKLIDES reported C-ANCA in 74% and 95%, respectively. P-ANCA was recognized by routine microscopy on ethanol-fixed neutrophils in 90%, while AKLIDES reported P-ANCA in 80%. Typically, only 65% and 33% of these samples showed the expected C-ANCA on formalin-fixed neutrophils by routine microscopy and AKLIDES, respectively. A C- or P-ANCA pattern was observed on ethanol-fixed neutrophils in 28% and 23% of the controls by routine microscopy and AKLIDES, respectively. Only 5% of the controls revealed C-ANCA on formalin-fixed neutrophils by routine microscopy and AKLIDES. Altogether, automated ANCA-pattern recognition by AKLIDES is promising. Distinction of C- and P-ANCA is good, but sensitivity on ethanol-fixed neutrophils needs improvement. When optimized, pattern recognition software may play an important role in AAV diagnostics. Hindawi Publishing Corporation 2012 2012-11-05 /pmc/articles/PMC3501831/ /pubmed/23193419 http://dx.doi.org/10.1155/2012/762874 Text en Copyright © 2012 Jan Damoiseaux et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Damoiseaux, Jan Mallet, Kathleen Vaessen, Mia Austen, Jos Cohen Tervaert, Jan Willem Automatic Reading of ANCA-Slides: Evaluation of the AKLIDES System |
title | Automatic Reading of ANCA-Slides: Evaluation of the AKLIDES System |
title_full | Automatic Reading of ANCA-Slides: Evaluation of the AKLIDES System |
title_fullStr | Automatic Reading of ANCA-Slides: Evaluation of the AKLIDES System |
title_full_unstemmed | Automatic Reading of ANCA-Slides: Evaluation of the AKLIDES System |
title_short | Automatic Reading of ANCA-Slides: Evaluation of the AKLIDES System |
title_sort | automatic reading of anca-slides: evaluation of the aklides system |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3501831/ https://www.ncbi.nlm.nih.gov/pubmed/23193419 http://dx.doi.org/10.1155/2012/762874 |
work_keys_str_mv | AT damoiseauxjan automaticreadingofancaslidesevaluationoftheaklidessystem AT malletkathleen automaticreadingofancaslidesevaluationoftheaklidessystem AT vaessenmia automaticreadingofancaslidesevaluationoftheaklidessystem AT austenjos automaticreadingofancaslidesevaluationoftheaklidessystem AT cohentervaertjanwillem automaticreadingofancaslidesevaluationoftheaklidessystem |