Cargando…

Automatic Reading of ANCA-Slides: Evaluation of the AKLIDES System

The ANCA consensus prescribes screening by indirect immunofluorescence on neutrophils. We evaluated the first automated ANCA-pattern recognition system. C-ANCA (n = 39) and P-ANCA (n = 40) samples were selected from patients with ANCA-associated vasculitis (AAV). Non-AAV controls included sera from...

Descripción completa

Detalles Bibliográficos
Autores principales: Damoiseaux, Jan, Mallet, Kathleen, Vaessen, Mia, Austen, Jos, Cohen Tervaert, Jan Willem
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3501831/
https://www.ncbi.nlm.nih.gov/pubmed/23193419
http://dx.doi.org/10.1155/2012/762874
_version_ 1782250226602475520
author Damoiseaux, Jan
Mallet, Kathleen
Vaessen, Mia
Austen, Jos
Cohen Tervaert, Jan Willem
author_facet Damoiseaux, Jan
Mallet, Kathleen
Vaessen, Mia
Austen, Jos
Cohen Tervaert, Jan Willem
author_sort Damoiseaux, Jan
collection PubMed
description The ANCA consensus prescribes screening by indirect immunofluorescence on neutrophils. We evaluated the first automated ANCA-pattern recognition system. C-ANCA (n = 39) and P-ANCA (n = 40) samples were selected from patients with ANCA-associated vasculitis (AAV). Non-AAV controls included sera from healthy controls (n = 40), sera with possible interfering antibodies (n = 46), or miscellaneous ANCA reactivity (n = 31). ANCA slides were analysed by AKLIDES and routine fluorescence microscopy. The C-ANCA pattern was recognized by routine microscopy in 92% and 97% on ethanol- and formalin-fixed slides, respectively. AKLIDES reported C-ANCA in 74% and 95%, respectively. P-ANCA was recognized by routine microscopy on ethanol-fixed neutrophils in 90%, while AKLIDES reported P-ANCA in 80%. Typically, only 65% and 33% of these samples showed the expected C-ANCA on formalin-fixed neutrophils by routine microscopy and AKLIDES, respectively. A C- or P-ANCA pattern was observed on ethanol-fixed neutrophils in 28% and 23% of the controls by routine microscopy and AKLIDES, respectively. Only 5% of the controls revealed C-ANCA on formalin-fixed neutrophils by routine microscopy and AKLIDES. Altogether, automated ANCA-pattern recognition by AKLIDES is promising. Distinction of C- and P-ANCA is good, but sensitivity on ethanol-fixed neutrophils needs improvement. When optimized, pattern recognition software may play an important role in AAV diagnostics.
format Online
Article
Text
id pubmed-3501831
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-35018312012-11-28 Automatic Reading of ANCA-Slides: Evaluation of the AKLIDES System Damoiseaux, Jan Mallet, Kathleen Vaessen, Mia Austen, Jos Cohen Tervaert, Jan Willem Clin Dev Immunol Research Article The ANCA consensus prescribes screening by indirect immunofluorescence on neutrophils. We evaluated the first automated ANCA-pattern recognition system. C-ANCA (n = 39) and P-ANCA (n = 40) samples were selected from patients with ANCA-associated vasculitis (AAV). Non-AAV controls included sera from healthy controls (n = 40), sera with possible interfering antibodies (n = 46), or miscellaneous ANCA reactivity (n = 31). ANCA slides were analysed by AKLIDES and routine fluorescence microscopy. The C-ANCA pattern was recognized by routine microscopy in 92% and 97% on ethanol- and formalin-fixed slides, respectively. AKLIDES reported C-ANCA in 74% and 95%, respectively. P-ANCA was recognized by routine microscopy on ethanol-fixed neutrophils in 90%, while AKLIDES reported P-ANCA in 80%. Typically, only 65% and 33% of these samples showed the expected C-ANCA on formalin-fixed neutrophils by routine microscopy and AKLIDES, respectively. A C- or P-ANCA pattern was observed on ethanol-fixed neutrophils in 28% and 23% of the controls by routine microscopy and AKLIDES, respectively. Only 5% of the controls revealed C-ANCA on formalin-fixed neutrophils by routine microscopy and AKLIDES. Altogether, automated ANCA-pattern recognition by AKLIDES is promising. Distinction of C- and P-ANCA is good, but sensitivity on ethanol-fixed neutrophils needs improvement. When optimized, pattern recognition software may play an important role in AAV diagnostics. Hindawi Publishing Corporation 2012 2012-11-05 /pmc/articles/PMC3501831/ /pubmed/23193419 http://dx.doi.org/10.1155/2012/762874 Text en Copyright © 2012 Jan Damoiseaux et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Damoiseaux, Jan
Mallet, Kathleen
Vaessen, Mia
Austen, Jos
Cohen Tervaert, Jan Willem
Automatic Reading of ANCA-Slides: Evaluation of the AKLIDES System
title Automatic Reading of ANCA-Slides: Evaluation of the AKLIDES System
title_full Automatic Reading of ANCA-Slides: Evaluation of the AKLIDES System
title_fullStr Automatic Reading of ANCA-Slides: Evaluation of the AKLIDES System
title_full_unstemmed Automatic Reading of ANCA-Slides: Evaluation of the AKLIDES System
title_short Automatic Reading of ANCA-Slides: Evaluation of the AKLIDES System
title_sort automatic reading of anca-slides: evaluation of the aklides system
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3501831/
https://www.ncbi.nlm.nih.gov/pubmed/23193419
http://dx.doi.org/10.1155/2012/762874
work_keys_str_mv AT damoiseauxjan automaticreadingofancaslidesevaluationoftheaklidessystem
AT malletkathleen automaticreadingofancaslidesevaluationoftheaklidessystem
AT vaessenmia automaticreadingofancaslidesevaluationoftheaklidessystem
AT austenjos automaticreadingofancaslidesevaluationoftheaklidessystem
AT cohentervaertjanwillem automaticreadingofancaslidesevaluationoftheaklidessystem