Cargando…
Simultaneous determination of lovastatin and niacin in tablet by first and third derivative spectrophotometry and H-point standard addition methods
Most cardiovascular diseases need to be treated by more than a simple drug and the use of combination products diminishes noncompliance. Advicor(®) as a combination product of a vitamin and a fat lowering agent has no monograph in official pharmacopeias for its quality control purposes. In this stud...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3501905/ https://www.ncbi.nlm.nih.gov/pubmed/23181086 |
_version_ | 1782250241713504256 |
---|---|
author | Kazemipour, M. Ansari, M. Ramezani, H. Moradalizadeh, M. |
author_facet | Kazemipour, M. Ansari, M. Ramezani, H. Moradalizadeh, M. |
author_sort | Kazemipour, M. |
collection | PubMed |
description | Most cardiovascular diseases need to be treated by more than a simple drug and the use of combination products diminishes noncompliance. Advicor(®) as a combination product of a vitamin and a fat lowering agent has no monograph in official pharmacopeias for its quality control purposes. In this study, first and third derivative signals for NA and LV quantitation at the two pairs of wavelengths, 261 and 273 nm; 245 and 249 nm were monitored with the addition of standard solutions of NA or LV, respectively. The limits of detection were 0.03 and 0.32 mg/L for LV and NA, respectively. The limits of quantitation were 0.09 and 0.78 mg/L for LV and NA, respectively. RSD% for both interday and intraday precision was lower than 2.6 and 2.7% for LV and NA, respectively. Selectivity of the method was assessed for both degradation products produced in stress conditions and common excipients that may present in the pharmaceutical dosage forms. The recommended procedure was successfully applied to real samples. |
format | Online Article Text |
id | pubmed-3501905 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-35019052012-11-23 Simultaneous determination of lovastatin and niacin in tablet by first and third derivative spectrophotometry and H-point standard addition methods Kazemipour, M. Ansari, M. Ramezani, H. Moradalizadeh, M. Res Pharm Sci Original Article Most cardiovascular diseases need to be treated by more than a simple drug and the use of combination products diminishes noncompliance. Advicor(®) as a combination product of a vitamin and a fat lowering agent has no monograph in official pharmacopeias for its quality control purposes. In this study, first and third derivative signals for NA and LV quantitation at the two pairs of wavelengths, 261 and 273 nm; 245 and 249 nm were monitored with the addition of standard solutions of NA or LV, respectively. The limits of detection were 0.03 and 0.32 mg/L for LV and NA, respectively. The limits of quantitation were 0.09 and 0.78 mg/L for LV and NA, respectively. RSD% for both interday and intraday precision was lower than 2.6 and 2.7% for LV and NA, respectively. Selectivity of the method was assessed for both degradation products produced in stress conditions and common excipients that may present in the pharmaceutical dosage forms. The recommended procedure was successfully applied to real samples. Medknow Publications & Media Pvt Ltd 2012 /pmc/articles/PMC3501905/ /pubmed/23181086 Text en Copyright: © Journal of Research in Pharmaceutical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kazemipour, M. Ansari, M. Ramezani, H. Moradalizadeh, M. Simultaneous determination of lovastatin and niacin in tablet by first and third derivative spectrophotometry and H-point standard addition methods |
title | Simultaneous determination of lovastatin and niacin in tablet by first and third derivative spectrophotometry and H-point standard addition methods |
title_full | Simultaneous determination of lovastatin and niacin in tablet by first and third derivative spectrophotometry and H-point standard addition methods |
title_fullStr | Simultaneous determination of lovastatin and niacin in tablet by first and third derivative spectrophotometry and H-point standard addition methods |
title_full_unstemmed | Simultaneous determination of lovastatin and niacin in tablet by first and third derivative spectrophotometry and H-point standard addition methods |
title_short | Simultaneous determination of lovastatin and niacin in tablet by first and third derivative spectrophotometry and H-point standard addition methods |
title_sort | simultaneous determination of lovastatin and niacin in tablet by first and third derivative spectrophotometry and h-point standard addition methods |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3501905/ https://www.ncbi.nlm.nih.gov/pubmed/23181086 |
work_keys_str_mv | AT kazemipourm simultaneousdeterminationoflovastatinandniacinintabletbyfirstandthirdderivativespectrophotometryandhpointstandardadditionmethods AT ansarim simultaneousdeterminationoflovastatinandniacinintabletbyfirstandthirdderivativespectrophotometryandhpointstandardadditionmethods AT ramezanih simultaneousdeterminationoflovastatinandniacinintabletbyfirstandthirdderivativespectrophotometryandhpointstandardadditionmethods AT moradalizadehm simultaneousdeterminationoflovastatinandniacinintabletbyfirstandthirdderivativespectrophotometryandhpointstandardadditionmethods |