Cargando…
Do the Microshear Test Variables Affect the Bond Strength Values?
Little is known about the effect of specimen preparation and testing protocols on the micro-shear bond strength (μSBS) results. To evaluate whether variations in polyethylene rod use affect (μSBS)). Human dentin disks were randomly distributed into six groups (n = 5): polyethylene tube (3 levels) an...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3502005/ https://www.ncbi.nlm.nih.gov/pubmed/23193406 http://dx.doi.org/10.1155/2012/618960 |
_version_ | 1782250253574995968 |
---|---|
author | Andrade, Andrea M. Garcia, Eugenio Moura, Sandra Kiss Reis, Alessandra Loguercio, Alessandro Silva, Luciana Mendonça Pimentel, Gustavo H. D. Grande, Rosa Helena Miranda |
author_facet | Andrade, Andrea M. Garcia, Eugenio Moura, Sandra Kiss Reis, Alessandra Loguercio, Alessandro Silva, Luciana Mendonça Pimentel, Gustavo H. D. Grande, Rosa Helena Miranda |
author_sort | Andrade, Andrea M. |
collection | PubMed |
description | Little is known about the effect of specimen preparation and testing protocols on the micro-shear bond strength (μSBS) results. To evaluate whether variations in polyethylene rod use affect (μSBS)). Human dentin disks were randomly distributed into six groups (n = 5): polyethylene tube (3 levels) and adhesive system (2 levels). In Group 1, polyethylene tubes filled with polymerized composite) were placed on adhesive covered surfaces. Tubes were removed 24 h after water storage, leaving the rods only. In Group 2, the same procedure was performed; however, tubes were kept in place during testing. In Group 3, composite rods without tubes were placed on adhesive covered dentin. In all groups, adhesives were photoactivated after positioning filled tubes/rods on adhesive covered surfaces. Specimens were tested under shear mode and the data subjected to a two-way ANOVA and Tukey's tests. Groups 1 and 2 resulted in statistically similar mean μSBS (P > 0.05); however, a greater number of pretest failures were observed for Group 1. Higher μSBS values were detected for Group 3, irrespective of adhesive system used (P < 0.05). Removing the polyethylene tube before composite rod is placed on dentin affects μSBS values. |
format | Online Article Text |
id | pubmed-3502005 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-35020052012-11-28 Do the Microshear Test Variables Affect the Bond Strength Values? Andrade, Andrea M. Garcia, Eugenio Moura, Sandra Kiss Reis, Alessandra Loguercio, Alessandro Silva, Luciana Mendonça Pimentel, Gustavo H. D. Grande, Rosa Helena Miranda Int J Dent Research Article Little is known about the effect of specimen preparation and testing protocols on the micro-shear bond strength (μSBS) results. To evaluate whether variations in polyethylene rod use affect (μSBS)). Human dentin disks were randomly distributed into six groups (n = 5): polyethylene tube (3 levels) and adhesive system (2 levels). In Group 1, polyethylene tubes filled with polymerized composite) were placed on adhesive covered surfaces. Tubes were removed 24 h after water storage, leaving the rods only. In Group 2, the same procedure was performed; however, tubes were kept in place during testing. In Group 3, composite rods without tubes were placed on adhesive covered dentin. In all groups, adhesives were photoactivated after positioning filled tubes/rods on adhesive covered surfaces. Specimens were tested under shear mode and the data subjected to a two-way ANOVA and Tukey's tests. Groups 1 and 2 resulted in statistically similar mean μSBS (P > 0.05); however, a greater number of pretest failures were observed for Group 1. Higher μSBS values were detected for Group 3, irrespective of adhesive system used (P < 0.05). Removing the polyethylene tube before composite rod is placed on dentin affects μSBS values. Hindawi Publishing Corporation 2012 2012-11-04 /pmc/articles/PMC3502005/ /pubmed/23193406 http://dx.doi.org/10.1155/2012/618960 Text en Copyright © 2012 Andrea M. Andrade et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Andrade, Andrea M. Garcia, Eugenio Moura, Sandra Kiss Reis, Alessandra Loguercio, Alessandro Silva, Luciana Mendonça Pimentel, Gustavo H. D. Grande, Rosa Helena Miranda Do the Microshear Test Variables Affect the Bond Strength Values? |
title | Do the Microshear Test Variables Affect the Bond Strength Values? |
title_full | Do the Microshear Test Variables Affect the Bond Strength Values? |
title_fullStr | Do the Microshear Test Variables Affect the Bond Strength Values? |
title_full_unstemmed | Do the Microshear Test Variables Affect the Bond Strength Values? |
title_short | Do the Microshear Test Variables Affect the Bond Strength Values? |
title_sort | do the microshear test variables affect the bond strength values? |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3502005/ https://www.ncbi.nlm.nih.gov/pubmed/23193406 http://dx.doi.org/10.1155/2012/618960 |
work_keys_str_mv | AT andradeandream dothemicrosheartestvariablesaffectthebondstrengthvalues AT garciaeugenio dothemicrosheartestvariablesaffectthebondstrengthvalues AT mourasandrakiss dothemicrosheartestvariablesaffectthebondstrengthvalues AT reisalessandra dothemicrosheartestvariablesaffectthebondstrengthvalues AT loguercioalessandro dothemicrosheartestvariablesaffectthebondstrengthvalues AT silvalucianamendonca dothemicrosheartestvariablesaffectthebondstrengthvalues AT pimentelgustavohd dothemicrosheartestvariablesaffectthebondstrengthvalues AT granderosahelenamiranda dothemicrosheartestvariablesaffectthebondstrengthvalues |