Cargando…

Do the Microshear Test Variables Affect the Bond Strength Values?

Little is known about the effect of specimen preparation and testing protocols on the micro-shear bond strength (μSBS) results. To evaluate whether variations in polyethylene rod use affect (μSBS)). Human dentin disks were randomly distributed into six groups (n = 5): polyethylene tube (3 levels) an...

Descripción completa

Detalles Bibliográficos
Autores principales: Andrade, Andrea M., Garcia, Eugenio, Moura, Sandra Kiss, Reis, Alessandra, Loguercio, Alessandro, Silva, Luciana Mendonça, Pimentel, Gustavo H. D., Grande, Rosa Helena Miranda
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3502005/
https://www.ncbi.nlm.nih.gov/pubmed/23193406
http://dx.doi.org/10.1155/2012/618960
_version_ 1782250253574995968
author Andrade, Andrea M.
Garcia, Eugenio
Moura, Sandra Kiss
Reis, Alessandra
Loguercio, Alessandro
Silva, Luciana Mendonça
Pimentel, Gustavo H. D.
Grande, Rosa Helena Miranda
author_facet Andrade, Andrea M.
Garcia, Eugenio
Moura, Sandra Kiss
Reis, Alessandra
Loguercio, Alessandro
Silva, Luciana Mendonça
Pimentel, Gustavo H. D.
Grande, Rosa Helena Miranda
author_sort Andrade, Andrea M.
collection PubMed
description Little is known about the effect of specimen preparation and testing protocols on the micro-shear bond strength (μSBS) results. To evaluate whether variations in polyethylene rod use affect (μSBS)). Human dentin disks were randomly distributed into six groups (n = 5): polyethylene tube (3 levels) and adhesive system (2 levels). In Group 1, polyethylene tubes filled with polymerized composite) were placed on adhesive covered surfaces. Tubes were removed 24 h after water storage, leaving the rods only. In Group 2, the same procedure was performed; however, tubes were kept in place during testing. In Group 3, composite rods without tubes were placed on adhesive covered dentin. In all groups, adhesives were photoactivated after positioning filled tubes/rods on adhesive covered surfaces. Specimens were tested under shear mode and the data subjected to a two-way ANOVA and Tukey's tests. Groups 1 and 2 resulted in statistically similar mean μSBS (P > 0.05); however, a greater number of pretest failures were observed for Group 1. Higher μSBS values were detected for Group 3, irrespective of adhesive system used (P < 0.05). Removing the polyethylene tube before composite rod is placed on dentin affects μSBS values.
format Online
Article
Text
id pubmed-3502005
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-35020052012-11-28 Do the Microshear Test Variables Affect the Bond Strength Values? Andrade, Andrea M. Garcia, Eugenio Moura, Sandra Kiss Reis, Alessandra Loguercio, Alessandro Silva, Luciana Mendonça Pimentel, Gustavo H. D. Grande, Rosa Helena Miranda Int J Dent Research Article Little is known about the effect of specimen preparation and testing protocols on the micro-shear bond strength (μSBS) results. To evaluate whether variations in polyethylene rod use affect (μSBS)). Human dentin disks were randomly distributed into six groups (n = 5): polyethylene tube (3 levels) and adhesive system (2 levels). In Group 1, polyethylene tubes filled with polymerized composite) were placed on adhesive covered surfaces. Tubes were removed 24 h after water storage, leaving the rods only. In Group 2, the same procedure was performed; however, tubes were kept in place during testing. In Group 3, composite rods without tubes were placed on adhesive covered dentin. In all groups, adhesives were photoactivated after positioning filled tubes/rods on adhesive covered surfaces. Specimens were tested under shear mode and the data subjected to a two-way ANOVA and Tukey's tests. Groups 1 and 2 resulted in statistically similar mean μSBS (P > 0.05); however, a greater number of pretest failures were observed for Group 1. Higher μSBS values were detected for Group 3, irrespective of adhesive system used (P < 0.05). Removing the polyethylene tube before composite rod is placed on dentin affects μSBS values. Hindawi Publishing Corporation 2012 2012-11-04 /pmc/articles/PMC3502005/ /pubmed/23193406 http://dx.doi.org/10.1155/2012/618960 Text en Copyright © 2012 Andrea M. Andrade et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Andrade, Andrea M.
Garcia, Eugenio
Moura, Sandra Kiss
Reis, Alessandra
Loguercio, Alessandro
Silva, Luciana Mendonça
Pimentel, Gustavo H. D.
Grande, Rosa Helena Miranda
Do the Microshear Test Variables Affect the Bond Strength Values?
title Do the Microshear Test Variables Affect the Bond Strength Values?
title_full Do the Microshear Test Variables Affect the Bond Strength Values?
title_fullStr Do the Microshear Test Variables Affect the Bond Strength Values?
title_full_unstemmed Do the Microshear Test Variables Affect the Bond Strength Values?
title_short Do the Microshear Test Variables Affect the Bond Strength Values?
title_sort do the microshear test variables affect the bond strength values?
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3502005/
https://www.ncbi.nlm.nih.gov/pubmed/23193406
http://dx.doi.org/10.1155/2012/618960
work_keys_str_mv AT andradeandream dothemicrosheartestvariablesaffectthebondstrengthvalues
AT garciaeugenio dothemicrosheartestvariablesaffectthebondstrengthvalues
AT mourasandrakiss dothemicrosheartestvariablesaffectthebondstrengthvalues
AT reisalessandra dothemicrosheartestvariablesaffectthebondstrengthvalues
AT loguercioalessandro dothemicrosheartestvariablesaffectthebondstrengthvalues
AT silvalucianamendonca dothemicrosheartestvariablesaffectthebondstrengthvalues
AT pimentelgustavohd dothemicrosheartestvariablesaffectthebondstrengthvalues
AT granderosahelenamiranda dothemicrosheartestvariablesaffectthebondstrengthvalues