Cargando…

Finite Volume Scheme for Double Convection-Diffusion Exchange of Solutes in Bicarbonate High-Flux Hollow-Fiber Dialyzer Therapy

The efficiency of a high-flux dialyzer in terms of buffering and toxic solute removal largely depends on the ability to use convection-diffusion mechanism inside the membrane. A two-dimensional transient convection-diffusion model coupled with acid-base correction term was developed. A finite volume...

Descripción completa

Detalles Bibliográficos
Autor principal: Annan, Kodwo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3502032/
https://www.ncbi.nlm.nih.gov/pubmed/23197994
http://dx.doi.org/10.1155/2012/973424
_version_ 1782250257062559744
author Annan, Kodwo
author_facet Annan, Kodwo
author_sort Annan, Kodwo
collection PubMed
description The efficiency of a high-flux dialyzer in terms of buffering and toxic solute removal largely depends on the ability to use convection-diffusion mechanism inside the membrane. A two-dimensional transient convection-diffusion model coupled with acid-base correction term was developed. A finite volume technique was used to discretize the model and to numerically simulate it using MATLAB software tool. We observed that small solute concentration gradients peaked and were large enough to activate solute diffusion process in the membrane. While CO(2) concentration gradients diminished from their maxima and shifted toward the end of the membrane, HCO(3) (−) concentration gradients peaked at the same position. Also, CO(2) concentration decreased rapidly within the first 47 minutes while optimal HCO(3) (−) concentration was achieved within 30 minutes of the therapy. Abnormally high diffusion fluxes were observed near the blood-membrane interface that increased diffusion driving force and enhanced the overall diffusive process. While convective flux dominated total flux during the dialysis session, there was a continuous interference between convection and diffusion fluxes that call for the need to seek minimal interference between these two mechanisms. This is critical for the effective design and operation of high-flux dialyzers.
format Online
Article
Text
id pubmed-3502032
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-35020322012-11-29 Finite Volume Scheme for Double Convection-Diffusion Exchange of Solutes in Bicarbonate High-Flux Hollow-Fiber Dialyzer Therapy Annan, Kodwo Comput Math Methods Med Research Article The efficiency of a high-flux dialyzer in terms of buffering and toxic solute removal largely depends on the ability to use convection-diffusion mechanism inside the membrane. A two-dimensional transient convection-diffusion model coupled with acid-base correction term was developed. A finite volume technique was used to discretize the model and to numerically simulate it using MATLAB software tool. We observed that small solute concentration gradients peaked and were large enough to activate solute diffusion process in the membrane. While CO(2) concentration gradients diminished from their maxima and shifted toward the end of the membrane, HCO(3) (−) concentration gradients peaked at the same position. Also, CO(2) concentration decreased rapidly within the first 47 minutes while optimal HCO(3) (−) concentration was achieved within 30 minutes of the therapy. Abnormally high diffusion fluxes were observed near the blood-membrane interface that increased diffusion driving force and enhanced the overall diffusive process. While convective flux dominated total flux during the dialysis session, there was a continuous interference between convection and diffusion fluxes that call for the need to seek minimal interference between these two mechanisms. This is critical for the effective design and operation of high-flux dialyzers. Hindawi Publishing Corporation 2012 2012-10-31 /pmc/articles/PMC3502032/ /pubmed/23197994 http://dx.doi.org/10.1155/2012/973424 Text en Copyright © 2012 Kodwo Annan. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Annan, Kodwo
Finite Volume Scheme for Double Convection-Diffusion Exchange of Solutes in Bicarbonate High-Flux Hollow-Fiber Dialyzer Therapy
title Finite Volume Scheme for Double Convection-Diffusion Exchange of Solutes in Bicarbonate High-Flux Hollow-Fiber Dialyzer Therapy
title_full Finite Volume Scheme for Double Convection-Diffusion Exchange of Solutes in Bicarbonate High-Flux Hollow-Fiber Dialyzer Therapy
title_fullStr Finite Volume Scheme for Double Convection-Diffusion Exchange of Solutes in Bicarbonate High-Flux Hollow-Fiber Dialyzer Therapy
title_full_unstemmed Finite Volume Scheme for Double Convection-Diffusion Exchange of Solutes in Bicarbonate High-Flux Hollow-Fiber Dialyzer Therapy
title_short Finite Volume Scheme for Double Convection-Diffusion Exchange of Solutes in Bicarbonate High-Flux Hollow-Fiber Dialyzer Therapy
title_sort finite volume scheme for double convection-diffusion exchange of solutes in bicarbonate high-flux hollow-fiber dialyzer therapy
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3502032/
https://www.ncbi.nlm.nih.gov/pubmed/23197994
http://dx.doi.org/10.1155/2012/973424
work_keys_str_mv AT annankodwo finitevolumeschemefordoubleconvectiondiffusionexchangeofsolutesinbicarbonatehighfluxhollowfiberdialyzertherapy