Cargando…
Acute Variations in Retinal Vascular Oxygen Content in a Rabbit Model of Retinal Venous Occlusion
PURPOSE: To study the variation in intravascular oxygen saturation (oximetry) during an acute retinal vein occlusion (RVO) using hyperspectral computed tomographic spectroscopy based oximetry measurements. METHODS: Thirty rabbits were dilated and anesthetized for experiments. Baseline oximetry measu...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3502464/ https://www.ncbi.nlm.nih.gov/pubmed/23185567 http://dx.doi.org/10.1371/journal.pone.0050179 |
_version_ | 1782250344961540096 |
---|---|
author | Jaime, Gilberto Raul Lopez Kashani, Amir H. Saati, Saloomeh Martin, Gabriel Chader, Gerald Humayun, Mark S. |
author_facet | Jaime, Gilberto Raul Lopez Kashani, Amir H. Saati, Saloomeh Martin, Gabriel Chader, Gerald Humayun, Mark S. |
author_sort | Jaime, Gilberto Raul Lopez |
collection | PubMed |
description | PURPOSE: To study the variation in intravascular oxygen saturation (oximetry) during an acute retinal vein occlusion (RVO) using hyperspectral computed tomographic spectroscopy based oximetry measurements. METHODS: Thirty rabbits were dilated and anesthetized for experiments. Baseline oximetry measurements were made using a custom-made hyperspectral computed tomographic imaging spectrometer coupled to a fundus camera. RVO were induced using argon green laser following an intravenous injection of Rose Bengal. RVO induction was confirmed by fluorescein angiography. Retinal oximetry measurements were repeated in arterial and venous branches one hour after RVO induction and up to 4 weeks afterwards. Comparison of retinal oximetry before and after vein occlusion was made using the Student T-test. RESULTS: One hour after RVO induction, we observed statistically significant reductions in the intravascular oxygen saturation in temporal retinal arteries (85.1±6.1% vs. 80.6±6.6%; p<0.0001) and veins (71.4±5.5% vs. 64.0±4.7%; p<0.0001). This decrease was reversible in animals that spontaneously recannulated the vein occlusion. There were no statistically significant differences in oxygen saturation in the nasal control arteries and veins before and after temporal vein RVO induction. CONCLUSIONS: We demonstrate, for the first time, acute changes in the intravascular oxygen content of retinal vessels 1 hour after RVO. These changes are reversible upon spontaneous recannulation of retinal vessels. This study demonstrates that hyperspectral computer tomographic spectroscopy based oximetry can detect physiological variations in intravascular retinal oxygen saturation. The study also provides the first qualitative and quantitative evidence of the variation in retinal vascular oxygen content directly attributable to an acute retinal vein occlusion. |
format | Online Article Text |
id | pubmed-3502464 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-35024642012-11-26 Acute Variations in Retinal Vascular Oxygen Content in a Rabbit Model of Retinal Venous Occlusion Jaime, Gilberto Raul Lopez Kashani, Amir H. Saati, Saloomeh Martin, Gabriel Chader, Gerald Humayun, Mark S. PLoS One Research Article PURPOSE: To study the variation in intravascular oxygen saturation (oximetry) during an acute retinal vein occlusion (RVO) using hyperspectral computed tomographic spectroscopy based oximetry measurements. METHODS: Thirty rabbits were dilated and anesthetized for experiments. Baseline oximetry measurements were made using a custom-made hyperspectral computed tomographic imaging spectrometer coupled to a fundus camera. RVO were induced using argon green laser following an intravenous injection of Rose Bengal. RVO induction was confirmed by fluorescein angiography. Retinal oximetry measurements were repeated in arterial and venous branches one hour after RVO induction and up to 4 weeks afterwards. Comparison of retinal oximetry before and after vein occlusion was made using the Student T-test. RESULTS: One hour after RVO induction, we observed statistically significant reductions in the intravascular oxygen saturation in temporal retinal arteries (85.1±6.1% vs. 80.6±6.6%; p<0.0001) and veins (71.4±5.5% vs. 64.0±4.7%; p<0.0001). This decrease was reversible in animals that spontaneously recannulated the vein occlusion. There were no statistically significant differences in oxygen saturation in the nasal control arteries and veins before and after temporal vein RVO induction. CONCLUSIONS: We demonstrate, for the first time, acute changes in the intravascular oxygen content of retinal vessels 1 hour after RVO. These changes are reversible upon spontaneous recannulation of retinal vessels. This study demonstrates that hyperspectral computer tomographic spectroscopy based oximetry can detect physiological variations in intravascular retinal oxygen saturation. The study also provides the first qualitative and quantitative evidence of the variation in retinal vascular oxygen content directly attributable to an acute retinal vein occlusion. Public Library of Science 2012-11-20 /pmc/articles/PMC3502464/ /pubmed/23185567 http://dx.doi.org/10.1371/journal.pone.0050179 Text en https://creativecommons.org/publicdomain/zero/1.0/ This is an open-access article distributed under the terms of the Creative Commons Public Domain declaration, which stipulates that, once placed in the public domain, this work may be freely reproduced, distributed, transmitted, modified, built upon, or otherwise used by anyone for any lawful purpose. |
spellingShingle | Research Article Jaime, Gilberto Raul Lopez Kashani, Amir H. Saati, Saloomeh Martin, Gabriel Chader, Gerald Humayun, Mark S. Acute Variations in Retinal Vascular Oxygen Content in a Rabbit Model of Retinal Venous Occlusion |
title | Acute Variations in Retinal Vascular Oxygen Content in a Rabbit Model of Retinal Venous Occlusion |
title_full | Acute Variations in Retinal Vascular Oxygen Content in a Rabbit Model of Retinal Venous Occlusion |
title_fullStr | Acute Variations in Retinal Vascular Oxygen Content in a Rabbit Model of Retinal Venous Occlusion |
title_full_unstemmed | Acute Variations in Retinal Vascular Oxygen Content in a Rabbit Model of Retinal Venous Occlusion |
title_short | Acute Variations in Retinal Vascular Oxygen Content in a Rabbit Model of Retinal Venous Occlusion |
title_sort | acute variations in retinal vascular oxygen content in a rabbit model of retinal venous occlusion |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3502464/ https://www.ncbi.nlm.nih.gov/pubmed/23185567 http://dx.doi.org/10.1371/journal.pone.0050179 |
work_keys_str_mv | AT jaimegilbertoraullopez acutevariationsinretinalvascularoxygencontentinarabbitmodelofretinalvenousocclusion AT kashaniamirh acutevariationsinretinalvascularoxygencontentinarabbitmodelofretinalvenousocclusion AT saatisaloomeh acutevariationsinretinalvascularoxygencontentinarabbitmodelofretinalvenousocclusion AT martingabriel acutevariationsinretinalvascularoxygencontentinarabbitmodelofretinalvenousocclusion AT chadergerald acutevariationsinretinalvascularoxygencontentinarabbitmodelofretinalvenousocclusion AT humayunmarks acutevariationsinretinalvascularoxygencontentinarabbitmodelofretinalvenousocclusion |