Cargando…

LC-MS-MS Measurements of Urinary Creatinine and the Application of Creatinine Normalization Technique on Cotinine in Smokers' 24 Hour Urine

A simple and sensitive high performance liquid chromatography-tandem mass spectrometry (HPLC-ESI-MS-MS) method was developed and validated for the quantification of creatinine in human urine. The analysis was carried out on an Agilent Zorbax Eclipse XDB-C18 column (2.1 × 150 mm, 3.5 μm). The mobile...

Descripción completa

Detalles Bibliográficos
Autores principales: Hou, Hongwei, Xiong, Wei, Zhang, Xiaotao, Song, Dongkui, Tang, Gangling, Hu, Qingyuan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3503330/
https://www.ncbi.nlm.nih.gov/pubmed/23209947
http://dx.doi.org/10.1155/2012/245415
_version_ 1782250431323308032
author Hou, Hongwei
Xiong, Wei
Zhang, Xiaotao
Song, Dongkui
Tang, Gangling
Hu, Qingyuan
author_facet Hou, Hongwei
Xiong, Wei
Zhang, Xiaotao
Song, Dongkui
Tang, Gangling
Hu, Qingyuan
author_sort Hou, Hongwei
collection PubMed
description A simple and sensitive high performance liquid chromatography-tandem mass spectrometry (HPLC-ESI-MS-MS) method was developed and validated for the quantification of creatinine in human urine. The analysis was carried out on an Agilent Zorbax Eclipse XDB-C18 column (2.1 × 150 mm, 3.5 μm). The mobile phase was 0.1% formic acid in water and 0.1% formic acid in acetonitrile (50/50, v/v). Linear calibration curves were obtained in the concentration range of 1–2000.0 ng/mL, with a lower limit of quantification of 0.99 ng/mL. The intra- and interday precision (RSD) values were below 3%. The method was successfully applied to a bioequivalence study of creatinine in Chinese smokers and nonsmokers. The total cotinine in 24 h urine and cotinine : creatinine ratio were also positively associated (Pearson R = 0.942, P < 0.0001). However, cotinine : creatinine ratio varied significantly across smoking groups for the difference of individual. 24 h urinary cotinine was more appropriate for expressing correlation with tar than cotinine : creatinine ratio.
format Online
Article
Text
id pubmed-3503330
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-35033302012-12-03 LC-MS-MS Measurements of Urinary Creatinine and the Application of Creatinine Normalization Technique on Cotinine in Smokers' 24 Hour Urine Hou, Hongwei Xiong, Wei Zhang, Xiaotao Song, Dongkui Tang, Gangling Hu, Qingyuan J Anal Methods Chem Research Article A simple and sensitive high performance liquid chromatography-tandem mass spectrometry (HPLC-ESI-MS-MS) method was developed and validated for the quantification of creatinine in human urine. The analysis was carried out on an Agilent Zorbax Eclipse XDB-C18 column (2.1 × 150 mm, 3.5 μm). The mobile phase was 0.1% formic acid in water and 0.1% formic acid in acetonitrile (50/50, v/v). Linear calibration curves were obtained in the concentration range of 1–2000.0 ng/mL, with a lower limit of quantification of 0.99 ng/mL. The intra- and interday precision (RSD) values were below 3%. The method was successfully applied to a bioequivalence study of creatinine in Chinese smokers and nonsmokers. The total cotinine in 24 h urine and cotinine : creatinine ratio were also positively associated (Pearson R = 0.942, P < 0.0001). However, cotinine : creatinine ratio varied significantly across smoking groups for the difference of individual. 24 h urinary cotinine was more appropriate for expressing correlation with tar than cotinine : creatinine ratio. Hindawi Publishing Corporation 2012 2012-11-11 /pmc/articles/PMC3503330/ /pubmed/23209947 http://dx.doi.org/10.1155/2012/245415 Text en Copyright © 2012 Hongwei Hou et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Hou, Hongwei
Xiong, Wei
Zhang, Xiaotao
Song, Dongkui
Tang, Gangling
Hu, Qingyuan
LC-MS-MS Measurements of Urinary Creatinine and the Application of Creatinine Normalization Technique on Cotinine in Smokers' 24 Hour Urine
title LC-MS-MS Measurements of Urinary Creatinine and the Application of Creatinine Normalization Technique on Cotinine in Smokers' 24 Hour Urine
title_full LC-MS-MS Measurements of Urinary Creatinine and the Application of Creatinine Normalization Technique on Cotinine in Smokers' 24 Hour Urine
title_fullStr LC-MS-MS Measurements of Urinary Creatinine and the Application of Creatinine Normalization Technique on Cotinine in Smokers' 24 Hour Urine
title_full_unstemmed LC-MS-MS Measurements of Urinary Creatinine and the Application of Creatinine Normalization Technique on Cotinine in Smokers' 24 Hour Urine
title_short LC-MS-MS Measurements of Urinary Creatinine and the Application of Creatinine Normalization Technique on Cotinine in Smokers' 24 Hour Urine
title_sort lc-ms-ms measurements of urinary creatinine and the application of creatinine normalization technique on cotinine in smokers' 24 hour urine
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3503330/
https://www.ncbi.nlm.nih.gov/pubmed/23209947
http://dx.doi.org/10.1155/2012/245415
work_keys_str_mv AT houhongwei lcmsmsmeasurementsofurinarycreatinineandtheapplicationofcreatininenormalizationtechniqueoncotinineinsmokers24hoururine
AT xiongwei lcmsmsmeasurementsofurinarycreatinineandtheapplicationofcreatininenormalizationtechniqueoncotinineinsmokers24hoururine
AT zhangxiaotao lcmsmsmeasurementsofurinarycreatinineandtheapplicationofcreatininenormalizationtechniqueoncotinineinsmokers24hoururine
AT songdongkui lcmsmsmeasurementsofurinarycreatinineandtheapplicationofcreatininenormalizationtechniqueoncotinineinsmokers24hoururine
AT tanggangling lcmsmsmeasurementsofurinarycreatinineandtheapplicationofcreatininenormalizationtechniqueoncotinineinsmokers24hoururine
AT huqingyuan lcmsmsmeasurementsofurinarycreatinineandtheapplicationofcreatininenormalizationtechniqueoncotinineinsmokers24hoururine