LC-MS-MS Measurements of Urinary Creatinine and the Application of Creatinine Normalization Technique on Cotinine in Smokers' 24 Hour Urine
A simple and sensitive high performance liquid chromatography-tandem mass spectrometry (HPLC-ESI-MS-MS) method was developed and validated for the quantification of creatinine in human urine. The analysis was carried out on an Agilent Zorbax Eclipse XDB-C18 column (2.1 × 150 mm, 3.5 μm). The mobile...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3503330/ https://www.ncbi.nlm.nih.gov/pubmed/23209947 http://dx.doi.org/10.1155/2012/245415 |
_version_ | 1782250431323308032 |
---|---|
author | Hou, Hongwei Xiong, Wei Zhang, Xiaotao Song, Dongkui Tang, Gangling Hu, Qingyuan |
author_facet | Hou, Hongwei Xiong, Wei Zhang, Xiaotao Song, Dongkui Tang, Gangling Hu, Qingyuan |
author_sort | Hou, Hongwei |
collection | PubMed |
description | A simple and sensitive high performance liquid chromatography-tandem mass spectrometry (HPLC-ESI-MS-MS) method was developed and validated for the quantification of creatinine in human urine. The analysis was carried out on an Agilent Zorbax Eclipse XDB-C18 column (2.1 × 150 mm, 3.5 μm). The mobile phase was 0.1% formic acid in water and 0.1% formic acid in acetonitrile (50/50, v/v). Linear calibration curves were obtained in the concentration range of 1–2000.0 ng/mL, with a lower limit of quantification of 0.99 ng/mL. The intra- and interday precision (RSD) values were below 3%. The method was successfully applied to a bioequivalence study of creatinine in Chinese smokers and nonsmokers. The total cotinine in 24 h urine and cotinine : creatinine ratio were also positively associated (Pearson R = 0.942, P < 0.0001). However, cotinine : creatinine ratio varied significantly across smoking groups for the difference of individual. 24 h urinary cotinine was more appropriate for expressing correlation with tar than cotinine : creatinine ratio. |
format | Online Article Text |
id | pubmed-3503330 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-35033302012-12-03 LC-MS-MS Measurements of Urinary Creatinine and the Application of Creatinine Normalization Technique on Cotinine in Smokers' 24 Hour Urine Hou, Hongwei Xiong, Wei Zhang, Xiaotao Song, Dongkui Tang, Gangling Hu, Qingyuan J Anal Methods Chem Research Article A simple and sensitive high performance liquid chromatography-tandem mass spectrometry (HPLC-ESI-MS-MS) method was developed and validated for the quantification of creatinine in human urine. The analysis was carried out on an Agilent Zorbax Eclipse XDB-C18 column (2.1 × 150 mm, 3.5 μm). The mobile phase was 0.1% formic acid in water and 0.1% formic acid in acetonitrile (50/50, v/v). Linear calibration curves were obtained in the concentration range of 1–2000.0 ng/mL, with a lower limit of quantification of 0.99 ng/mL. The intra- and interday precision (RSD) values were below 3%. The method was successfully applied to a bioequivalence study of creatinine in Chinese smokers and nonsmokers. The total cotinine in 24 h urine and cotinine : creatinine ratio were also positively associated (Pearson R = 0.942, P < 0.0001). However, cotinine : creatinine ratio varied significantly across smoking groups for the difference of individual. 24 h urinary cotinine was more appropriate for expressing correlation with tar than cotinine : creatinine ratio. Hindawi Publishing Corporation 2012 2012-11-11 /pmc/articles/PMC3503330/ /pubmed/23209947 http://dx.doi.org/10.1155/2012/245415 Text en Copyright © 2012 Hongwei Hou et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Hou, Hongwei Xiong, Wei Zhang, Xiaotao Song, Dongkui Tang, Gangling Hu, Qingyuan LC-MS-MS Measurements of Urinary Creatinine and the Application of Creatinine Normalization Technique on Cotinine in Smokers' 24 Hour Urine |
title | LC-MS-MS Measurements of Urinary Creatinine and the Application of Creatinine Normalization Technique on Cotinine in Smokers' 24 Hour Urine |
title_full | LC-MS-MS Measurements of Urinary Creatinine and the Application of Creatinine Normalization Technique on Cotinine in Smokers' 24 Hour Urine |
title_fullStr | LC-MS-MS Measurements of Urinary Creatinine and the Application of Creatinine Normalization Technique on Cotinine in Smokers' 24 Hour Urine |
title_full_unstemmed | LC-MS-MS Measurements of Urinary Creatinine and the Application of Creatinine Normalization Technique on Cotinine in Smokers' 24 Hour Urine |
title_short | LC-MS-MS Measurements of Urinary Creatinine and the Application of Creatinine Normalization Technique on Cotinine in Smokers' 24 Hour Urine |
title_sort | lc-ms-ms measurements of urinary creatinine and the application of creatinine normalization technique on cotinine in smokers' 24 hour urine |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3503330/ https://www.ncbi.nlm.nih.gov/pubmed/23209947 http://dx.doi.org/10.1155/2012/245415 |
work_keys_str_mv | AT houhongwei lcmsmsmeasurementsofurinarycreatinineandtheapplicationofcreatininenormalizationtechniqueoncotinineinsmokers24hoururine AT xiongwei lcmsmsmeasurementsofurinarycreatinineandtheapplicationofcreatininenormalizationtechniqueoncotinineinsmokers24hoururine AT zhangxiaotao lcmsmsmeasurementsofurinarycreatinineandtheapplicationofcreatininenormalizationtechniqueoncotinineinsmokers24hoururine AT songdongkui lcmsmsmeasurementsofurinarycreatinineandtheapplicationofcreatininenormalizationtechniqueoncotinineinsmokers24hoururine AT tanggangling lcmsmsmeasurementsofurinarycreatinineandtheapplicationofcreatininenormalizationtechniqueoncotinineinsmokers24hoururine AT huqingyuan lcmsmsmeasurementsofurinarycreatinineandtheapplicationofcreatininenormalizationtechniqueoncotinineinsmokers24hoururine |