Influence of image acquisition settings on radiation dose and image quality in coronary angiography by 320-detector volume computed tomography: the CORE320 pilot experience

The objective of this study was to investigate the impact of image acquisition settings and patients' characteristics on image quality and radiation dose for coronary angiography by 320-row computed tomography (CT). CORE320 is a prospective study to investigate the diagnostic performance of 320...

Descripción completa

Detalles Bibliográficos
Autores principales: Yoneyama, Kihei, Vavere, Andrea L., Cerci, Rodrigo, Ahmed, Rukhsar, Arai, Andrew E., Niinuma, Hiroyuki, Rybicki, Frank J., Rochitte, Carlos E., Clouse, Melvin E., George, Richard T., Lima, Joao A.C., Arbab-Zadeh, Armin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: PAGEPress Publications 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3504303/
https://www.ncbi.nlm.nih.gov/pubmed/23185678
http://dx.doi.org/10.4081/hi.2012.e11
_version_ 1782250610357174272
author Yoneyama, Kihei
Vavere, Andrea L.
Cerci, Rodrigo
Ahmed, Rukhsar
Arai, Andrew E.
Niinuma, Hiroyuki
Rybicki, Frank J.
Rochitte, Carlos E.
Clouse, Melvin E.
George, Richard T.
Lima, Joao A.C.
Arbab-Zadeh, Armin
author_facet Yoneyama, Kihei
Vavere, Andrea L.
Cerci, Rodrigo
Ahmed, Rukhsar
Arai, Andrew E.
Niinuma, Hiroyuki
Rybicki, Frank J.
Rochitte, Carlos E.
Clouse, Melvin E.
George, Richard T.
Lima, Joao A.C.
Arbab-Zadeh, Armin
author_sort Yoneyama, Kihei
collection PubMed
description The objective of this study was to investigate the impact of image acquisition settings and patients' characteristics on image quality and radiation dose for coronary angiography by 320-row computed tomography (CT). CORE320 is a prospective study to investigate the diagnostic performance of 320-detector CT for detecting coronary artery disease and associated myocardial ischemia. A run-in phase in 65 subjects was conducted to test the adequacy of the computed tomography angiography (CTA) acquisition protocol. Tube current, exposure window, and number of cardiac beats per acquisition were adjusted according to subjects' gender, heart rate, and body mass index (BMI). Main outcome measures were image quality, assessed by contrast/noise measurements and qualitatively on a 4-point scale, and radiation dose, estimated by the dose-length-product. Average heart rate at image acquisition was 55.0±7.3 bpm. Median Agatston calcium score was 27.0 (interquartile range 1–330). All scans were prospectively triggered. Single heart beat image acquisition was obtained in 61 of 65 studies (94%). Sixty-one studies (94%) and 437 of 455 arterial segments (96%) were of diagnostic image quality. Estimated radiation dose was significantly greater in obese (5.3±0.4 mSv) than normal weight (4.6±0.3 mSv) or overweight (4.7±0.3 mSv) subjects (P<0.001). BMI was the strongest factor influencing image quality (odds ratio=1.457, P=0.005). The CORE320 CTA image acquisition protocol achieved a good balance between image quality and radiation dose for a 320-detector CT system. However, image quality in obese subjects was reduced compared to normal weight subjects, possibly due to tube voltage/current restrictions mandated by the study protocol.
format Online
Article
Text
id pubmed-3504303
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher PAGEPress Publications
record_format MEDLINE/PubMed
spelling pubmed-35043032012-11-26 Influence of image acquisition settings on radiation dose and image quality in coronary angiography by 320-detector volume computed tomography: the CORE320 pilot experience Yoneyama, Kihei Vavere, Andrea L. Cerci, Rodrigo Ahmed, Rukhsar Arai, Andrew E. Niinuma, Hiroyuki Rybicki, Frank J. Rochitte, Carlos E. Clouse, Melvin E. George, Richard T. Lima, Joao A.C. Arbab-Zadeh, Armin Heart Int Clinical Investigation The objective of this study was to investigate the impact of image acquisition settings and patients' characteristics on image quality and radiation dose for coronary angiography by 320-row computed tomography (CT). CORE320 is a prospective study to investigate the diagnostic performance of 320-detector CT for detecting coronary artery disease and associated myocardial ischemia. A run-in phase in 65 subjects was conducted to test the adequacy of the computed tomography angiography (CTA) acquisition protocol. Tube current, exposure window, and number of cardiac beats per acquisition were adjusted according to subjects' gender, heart rate, and body mass index (BMI). Main outcome measures were image quality, assessed by contrast/noise measurements and qualitatively on a 4-point scale, and radiation dose, estimated by the dose-length-product. Average heart rate at image acquisition was 55.0±7.3 bpm. Median Agatston calcium score was 27.0 (interquartile range 1–330). All scans were prospectively triggered. Single heart beat image acquisition was obtained in 61 of 65 studies (94%). Sixty-one studies (94%) and 437 of 455 arterial segments (96%) were of diagnostic image quality. Estimated radiation dose was significantly greater in obese (5.3±0.4 mSv) than normal weight (4.6±0.3 mSv) or overweight (4.7±0.3 mSv) subjects (P<0.001). BMI was the strongest factor influencing image quality (odds ratio=1.457, P=0.005). The CORE320 CTA image acquisition protocol achieved a good balance between image quality and radiation dose for a 320-detector CT system. However, image quality in obese subjects was reduced compared to normal weight subjects, possibly due to tube voltage/current restrictions mandated by the study protocol. PAGEPress Publications 2012-06-25 /pmc/articles/PMC3504303/ /pubmed/23185678 http://dx.doi.org/10.4081/hi.2012.e11 Text en ©Copyright K. Yoneyama et al., 2012 This work is licensed under a Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0). Licensee PAGEPress, Italy
spellingShingle Clinical Investigation
Yoneyama, Kihei
Vavere, Andrea L.
Cerci, Rodrigo
Ahmed, Rukhsar
Arai, Andrew E.
Niinuma, Hiroyuki
Rybicki, Frank J.
Rochitte, Carlos E.
Clouse, Melvin E.
George, Richard T.
Lima, Joao A.C.
Arbab-Zadeh, Armin
Influence of image acquisition settings on radiation dose and image quality in coronary angiography by 320-detector volume computed tomography: the CORE320 pilot experience
title Influence of image acquisition settings on radiation dose and image quality in coronary angiography by 320-detector volume computed tomography: the CORE320 pilot experience
title_full Influence of image acquisition settings on radiation dose and image quality in coronary angiography by 320-detector volume computed tomography: the CORE320 pilot experience
title_fullStr Influence of image acquisition settings on radiation dose and image quality in coronary angiography by 320-detector volume computed tomography: the CORE320 pilot experience
title_full_unstemmed Influence of image acquisition settings on radiation dose and image quality in coronary angiography by 320-detector volume computed tomography: the CORE320 pilot experience
title_short Influence of image acquisition settings on radiation dose and image quality in coronary angiography by 320-detector volume computed tomography: the CORE320 pilot experience
title_sort influence of image acquisition settings on radiation dose and image quality in coronary angiography by 320-detector volume computed tomography: the core320 pilot experience
topic Clinical Investigation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3504303/
https://www.ncbi.nlm.nih.gov/pubmed/23185678
http://dx.doi.org/10.4081/hi.2012.e11
work_keys_str_mv AT yoneyamakihei influenceofimageacquisitionsettingsonradiationdoseandimagequalityincoronaryangiographyby320detectorvolumecomputedtomographythecore320pilotexperience
AT vavereandreal influenceofimageacquisitionsettingsonradiationdoseandimagequalityincoronaryangiographyby320detectorvolumecomputedtomographythecore320pilotexperience
AT cercirodrigo influenceofimageacquisitionsettingsonradiationdoseandimagequalityincoronaryangiographyby320detectorvolumecomputedtomographythecore320pilotexperience
AT ahmedrukhsar influenceofimageacquisitionsettingsonradiationdoseandimagequalityincoronaryangiographyby320detectorvolumecomputedtomographythecore320pilotexperience
AT araiandrewe influenceofimageacquisitionsettingsonradiationdoseandimagequalityincoronaryangiographyby320detectorvolumecomputedtomographythecore320pilotexperience
AT niinumahiroyuki influenceofimageacquisitionsettingsonradiationdoseandimagequalityincoronaryangiographyby320detectorvolumecomputedtomographythecore320pilotexperience
AT rybickifrankj influenceofimageacquisitionsettingsonradiationdoseandimagequalityincoronaryangiographyby320detectorvolumecomputedtomographythecore320pilotexperience
AT rochittecarlose influenceofimageacquisitionsettingsonradiationdoseandimagequalityincoronaryangiographyby320detectorvolumecomputedtomographythecore320pilotexperience
AT clousemelvine influenceofimageacquisitionsettingsonradiationdoseandimagequalityincoronaryangiographyby320detectorvolumecomputedtomographythecore320pilotexperience
AT georgerichardt influenceofimageacquisitionsettingsonradiationdoseandimagequalityincoronaryangiographyby320detectorvolumecomputedtomographythecore320pilotexperience
AT limajoaoac influenceofimageacquisitionsettingsonradiationdoseandimagequalityincoronaryangiographyby320detectorvolumecomputedtomographythecore320pilotexperience
AT arbabzadeharmin influenceofimageacquisitionsettingsonradiationdoseandimagequalityincoronaryangiographyby320detectorvolumecomputedtomographythecore320pilotexperience