Cargando…

The effects of image compression on quantitative measurements of digital panoramic radiographs

Objectives: The aims of this study were to explore how image compression affects density, fractal dimension, linear and angular measurements on digital panoramic images and assess inter and intra-observer repeatability of these measurements. Study Design: Sixty-one digital panoramic images in TIFF f...

Descripción completa

Detalles Bibliográficos
Autores principales: Yasar, Füsun, Apaydın, Burcu, Yılmaz, Hasan-Hüseyin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medicina Oral S.L. 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3505705/
https://www.ncbi.nlm.nih.gov/pubmed/22926465
http://dx.doi.org/10.4317/medoral.17912
_version_ 1782250795275649024
author Yasar, Füsun
Apaydın, Burcu
Yılmaz, Hasan-Hüseyin
author_facet Yasar, Füsun
Apaydın, Burcu
Yılmaz, Hasan-Hüseyin
author_sort Yasar, Füsun
collection PubMed
description Objectives: The aims of this study were to explore how image compression affects density, fractal dimension, linear and angular measurements on digital panoramic images and assess inter and intra-observer repeatability of these measurements. Study Design: Sixty-one digital panoramic images in TIFF format (Tagged Image File Format) were compressed to JPEG (Joint Photographic Experts Group) images. Two observers measured gonial angle, antegonial angle, mandibular cortical width, coronal pulp width of maxillary and mandibular first molar, tooth length of maxillary and mandibular first molar on the left side of these images twice. Fractal dimension of the selected regions of interests were calculated and the density of each panoramic radiograph as a whole were also measured on TIFF and JPEG compressed images. Intra-observer and inter-observer consistency was evaluated with Cronbach’s alpha. Paired samples t-test and Kolmogorov-Smirnov test was used to evaluate the difference between the measurements of TIFF and JPEG compressed images. Results: The repeatability of angular measurements had the highest Cronbach’s alpha value (0.997). There was statistically significant difference for both of the observers in mandibular cortical width (MCW) measurements (1st ob. p: 0.002; 2nd ob. p: 0.003), density (p<0.001) and fractal dimension (p<0.001) between TIFF and JPEG images. There was statistically significant difference for the first observer in antegonial angle (1st ob p< 0.001) and maxillary molar coronal pulp width (1st ob. p<0.001) between JPEG and TIFF files. Conclusions: The repeatability of angular measurements is better than linear measurements. Mandibular cortical width, fractal dimension and density are affected from compression. Observer dependent factors might also cause statistically significant differences between the measurements in TIFF and JPEG images. Key words:Digital panoramic radiography, image compression, linear measurements, angular measurements, fractal dimension.
format Online
Article
Text
id pubmed-3505705
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Medicina Oral S.L.
record_format MEDLINE/PubMed
spelling pubmed-35057052012-12-03 The effects of image compression on quantitative measurements of digital panoramic radiographs Yasar, Füsun Apaydın, Burcu Yılmaz, Hasan-Hüseyin Med Oral Patol Oral Cir Bucal Research-Article Objectives: The aims of this study were to explore how image compression affects density, fractal dimension, linear and angular measurements on digital panoramic images and assess inter and intra-observer repeatability of these measurements. Study Design: Sixty-one digital panoramic images in TIFF format (Tagged Image File Format) were compressed to JPEG (Joint Photographic Experts Group) images. Two observers measured gonial angle, antegonial angle, mandibular cortical width, coronal pulp width of maxillary and mandibular first molar, tooth length of maxillary and mandibular first molar on the left side of these images twice. Fractal dimension of the selected regions of interests were calculated and the density of each panoramic radiograph as a whole were also measured on TIFF and JPEG compressed images. Intra-observer and inter-observer consistency was evaluated with Cronbach’s alpha. Paired samples t-test and Kolmogorov-Smirnov test was used to evaluate the difference between the measurements of TIFF and JPEG compressed images. Results: The repeatability of angular measurements had the highest Cronbach’s alpha value (0.997). There was statistically significant difference for both of the observers in mandibular cortical width (MCW) measurements (1st ob. p: 0.002; 2nd ob. p: 0.003), density (p<0.001) and fractal dimension (p<0.001) between TIFF and JPEG images. There was statistically significant difference for the first observer in antegonial angle (1st ob p< 0.001) and maxillary molar coronal pulp width (1st ob. p<0.001) between JPEG and TIFF files. Conclusions: The repeatability of angular measurements is better than linear measurements. Mandibular cortical width, fractal dimension and density are affected from compression. Observer dependent factors might also cause statistically significant differences between the measurements in TIFF and JPEG images. Key words:Digital panoramic radiography, image compression, linear measurements, angular measurements, fractal dimension. Medicina Oral S.L. 2012-11 2012-08-28 /pmc/articles/PMC3505705/ /pubmed/22926465 http://dx.doi.org/10.4317/medoral.17912 Text en Copyright: © 2012 Medicina Oral S.L. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research-Article
Yasar, Füsun
Apaydın, Burcu
Yılmaz, Hasan-Hüseyin
The effects of image compression on quantitative measurements of digital panoramic radiographs
title The effects of image compression on quantitative measurements of digital panoramic radiographs
title_full The effects of image compression on quantitative measurements of digital panoramic radiographs
title_fullStr The effects of image compression on quantitative measurements of digital panoramic radiographs
title_full_unstemmed The effects of image compression on quantitative measurements of digital panoramic radiographs
title_short The effects of image compression on quantitative measurements of digital panoramic radiographs
title_sort effects of image compression on quantitative measurements of digital panoramic radiographs
topic Research-Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3505705/
https://www.ncbi.nlm.nih.gov/pubmed/22926465
http://dx.doi.org/10.4317/medoral.17912
work_keys_str_mv AT yasarfusun theeffectsofimagecompressiononquantitativemeasurementsofdigitalpanoramicradiographs
AT apaydınburcu theeffectsofimagecompressiononquantitativemeasurementsofdigitalpanoramicradiographs
AT yılmazhasanhuseyin theeffectsofimagecompressiononquantitativemeasurementsofdigitalpanoramicradiographs
AT yasarfusun effectsofimagecompressiononquantitativemeasurementsofdigitalpanoramicradiographs
AT apaydınburcu effectsofimagecompressiononquantitativemeasurementsofdigitalpanoramicradiographs
AT yılmazhasanhuseyin effectsofimagecompressiononquantitativemeasurementsofdigitalpanoramicradiographs