Cargando…
Satisfaction levels and asthma control amongst Malaysian asthmatic patients on budesonide/formoterol maintenance and reliever therapy: experience in a real-life setting
BACKGROUND: Budesonide/formoterol used for both maintenance and reliever therapy has been shown to benefit patients with persistent asthma. We evaluated patient satisfaction and asthma control among Malaysian patients prescribed budesonide/formoterol as single maintenance and reliever therapy in a r...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3506021/ https://www.ncbi.nlm.nih.gov/pubmed/23185124 http://dx.doi.org/10.2147/PROM.S19211 |
Sumario: | BACKGROUND: Budesonide/formoterol used for both maintenance and reliever therapy has been shown to benefit patients with persistent asthma. We evaluated patient satisfaction and asthma control among Malaysian patients prescribed budesonide/formoterol as single maintenance and reliever therapy in a real-life clinical practice. METHODS: Adult patients diagnosed with partially controlled or uncontrolled asthma were recruited in a 6-month, prospective, open-label study involving ten hospital-based chest clinics in Malaysia. Patients were prescribed one or two inhalations of budesonide/formoterol Turbuhaler (160/4.5 μg per inhalation) twice daily as maintenance therapy and additional inhalation as reliever therapy. Maintenance doses were decided by physicians based on Global Initiative for Asthma-defined treatment objectives. The primary outcome measure was the change in mean Satisfaction with Asthma Treatment Questionnaire (SATQ) scores from baseline to an average of 3 months and 6 months. Secondary outcome was the change in mean Asthma Control Questionnaire 5-item version (ACQ-5) scores from baseline to an average of 3 months and 6 months and the proportion of patients achieving the minimum clinically important difference. RESULTS: Of 201 eligible patients recruited, 195 completed the study. Overall, SATQ mean (standard deviation) score was significantly improved from 5.1 (0.76) at baseline to 5.5 (0.58) (P < 0.001). The increase was observed in all domains of SATQ and had occurred at 3 months for most patients. ACQ-5 mean (standard deviation) score was significantly reduced from 2.2 (1.13) at baseline to 1.2 (0.95) (P < 0.001). A total of 132 (67.7.1%) patients had achieved the minimal clinically important difference (≥0.5) of ACQ-5 scores at study end. CONCLUSION: In a nationwide study, budesonide/formoterol maintenance and reliever therapy achieved greater patient satisfaction and better asthma control compared with previous conventional asthma regimes among Malaysian patients treated in a real-life practice setting. Such an approach may represent an important treatment alternative for our local patients with persistent asthma. |
---|