Cargando…

Long-Term Evolution of the Electrical Stimulation Levels for Cochlear Implant Patients

OBJECTIVES: The stimulation levels programmed in cochlear implant systems are affected by an evolution since the first switch-on of the processor. This study was designed to evaluate the changes in stimulation levels over time and the relationship between post-implantation physiological changes and...

Descripción completa

Detalles Bibliográficos
Autores principales: Vargas, Jose Luis, Sainz, Manuel, Roldan, Cristina, Alvarez, Isaac, de la Torre, Angel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Otorhinolaryngology-Head and Neck Surgery 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3506769/
https://www.ncbi.nlm.nih.gov/pubmed/23205223
http://dx.doi.org/10.3342/ceo.2012.5.4.194
_version_ 1782250952905981952
author Vargas, Jose Luis
Sainz, Manuel
Roldan, Cristina
Alvarez, Isaac
de la Torre, Angel
author_facet Vargas, Jose Luis
Sainz, Manuel
Roldan, Cristina
Alvarez, Isaac
de la Torre, Angel
author_sort Vargas, Jose Luis
collection PubMed
description OBJECTIVES: The stimulation levels programmed in cochlear implant systems are affected by an evolution since the first switch-on of the processor. This study was designed to evaluate the changes in stimulation levels over time and the relationship between post-implantation physiological changes and with the hearing experience provided by the continuous use of the cochlear implant. METHODS: Sixty-two patients, ranging in age from 4 to 68 years at the moment of implantation participated in this study. All subjects were implanted with the 12 channels COMBI 40+ cochlear implant at San Cecilio University Hospital, Granada, Spain. Hearing loss etiology and progression characteristics varied across subjects. RESULTS: The analyzed programming maps show that the stimulation levels suffer a fast evolution during the first weeks after the first switch-on of the processor. Then, the evolution becomes slower and the programming parameters tend to be stable at about 6 months after the first switch-on. The evolution of the stimulation levels implies an increment of the electrical dynamic range, which is increased from 15.4 to 20.7 dB and improves the intensity resolution. A significant increment of the sensitivity to acoustic stimuli is also observed. For some patients, we have also observed transitory changes in the electrode impedances associated to secretory otitis media, which cause important changes in the programming maps. CONCLUSION: We have studied the long-term evolution of the stimulation levels in cochlear implant patients. Our results show the importance of systematic measurements of the electrode impedances before the revision of the programming map. This report also highlights that the evolution of the programming maps is an important factor to be considered in order to determine an adequate calendar fitting of the cochlear implant processor.
format Online
Article
Text
id pubmed-3506769
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Korean Society of Otorhinolaryngology-Head and Neck Surgery
record_format MEDLINE/PubMed
spelling pubmed-35067692012-12-01 Long-Term Evolution of the Electrical Stimulation Levels for Cochlear Implant Patients Vargas, Jose Luis Sainz, Manuel Roldan, Cristina Alvarez, Isaac de la Torre, Angel Clin Exp Otorhinolaryngol Original Article OBJECTIVES: The stimulation levels programmed in cochlear implant systems are affected by an evolution since the first switch-on of the processor. This study was designed to evaluate the changes in stimulation levels over time and the relationship between post-implantation physiological changes and with the hearing experience provided by the continuous use of the cochlear implant. METHODS: Sixty-two patients, ranging in age from 4 to 68 years at the moment of implantation participated in this study. All subjects were implanted with the 12 channels COMBI 40+ cochlear implant at San Cecilio University Hospital, Granada, Spain. Hearing loss etiology and progression characteristics varied across subjects. RESULTS: The analyzed programming maps show that the stimulation levels suffer a fast evolution during the first weeks after the first switch-on of the processor. Then, the evolution becomes slower and the programming parameters tend to be stable at about 6 months after the first switch-on. The evolution of the stimulation levels implies an increment of the electrical dynamic range, which is increased from 15.4 to 20.7 dB and improves the intensity resolution. A significant increment of the sensitivity to acoustic stimuli is also observed. For some patients, we have also observed transitory changes in the electrode impedances associated to secretory otitis media, which cause important changes in the programming maps. CONCLUSION: We have studied the long-term evolution of the stimulation levels in cochlear implant patients. Our results show the importance of systematic measurements of the electrode impedances before the revision of the programming map. This report also highlights that the evolution of the programming maps is an important factor to be considered in order to determine an adequate calendar fitting of the cochlear implant processor. Korean Society of Otorhinolaryngology-Head and Neck Surgery 2012-12 2012-11-13 /pmc/articles/PMC3506769/ /pubmed/23205223 http://dx.doi.org/10.3342/ceo.2012.5.4.194 Text en Copyright © 2012 by Korean Society of Otorhinolaryngology-Head and Neck Surgery. http://creativecommons.org/licenses/by-nc/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Vargas, Jose Luis
Sainz, Manuel
Roldan, Cristina
Alvarez, Isaac
de la Torre, Angel
Long-Term Evolution of the Electrical Stimulation Levels for Cochlear Implant Patients
title Long-Term Evolution of the Electrical Stimulation Levels for Cochlear Implant Patients
title_full Long-Term Evolution of the Electrical Stimulation Levels for Cochlear Implant Patients
title_fullStr Long-Term Evolution of the Electrical Stimulation Levels for Cochlear Implant Patients
title_full_unstemmed Long-Term Evolution of the Electrical Stimulation Levels for Cochlear Implant Patients
title_short Long-Term Evolution of the Electrical Stimulation Levels for Cochlear Implant Patients
title_sort long-term evolution of the electrical stimulation levels for cochlear implant patients
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3506769/
https://www.ncbi.nlm.nih.gov/pubmed/23205223
http://dx.doi.org/10.3342/ceo.2012.5.4.194
work_keys_str_mv AT vargasjoseluis longtermevolutionoftheelectricalstimulationlevelsforcochlearimplantpatients
AT sainzmanuel longtermevolutionoftheelectricalstimulationlevelsforcochlearimplantpatients
AT roldancristina longtermevolutionoftheelectricalstimulationlevelsforcochlearimplantpatients
AT alvarezisaac longtermevolutionoftheelectricalstimulationlevelsforcochlearimplantpatients
AT delatorreangel longtermevolutionoftheelectricalstimulationlevelsforcochlearimplantpatients