Cargando…

Fracture of J-tipped guidewire during central venous catheterization and its successful removal under fluoroscopic guidance -A case report-

Central venous catheterization by Seldinger's technique uses a guidewire which may cause complications such as kinking, knotting and fracture. Fractured guidewire may lead to severe outcomes such as embolization, and removal of it may also cause problems such as vessel damage. We experienced a...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Sun Kyung, Yi, In-Kyong, Lee, Jae-Ho, Kim, Dae-Hee, Lee, Sook Young
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Anesthesiologists 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3506858/
https://www.ncbi.nlm.nih.gov/pubmed/23198042
http://dx.doi.org/10.4097/kjae.2012.63.5.457
_version_ 1782250965939781632
author Park, Sun Kyung
Yi, In-Kyong
Lee, Jae-Ho
Kim, Dae-Hee
Lee, Sook Young
author_facet Park, Sun Kyung
Yi, In-Kyong
Lee, Jae-Ho
Kim, Dae-Hee
Lee, Sook Young
author_sort Park, Sun Kyung
collection PubMed
description Central venous catheterization by Seldinger's technique uses a guidewire which may cause complications such as kinking, knotting and fracture. Fractured guidewire may lead to severe outcomes such as embolization, and removal of it may also cause problems such as vessel damage. We experienced a case of right internal jugular venous catheterization complicated by guidewire fracture entrapped in the central venous catheter, and its successful removal under fluoroscopic guidance using snare-loop. The patient recovered without any complications. When resistance is felt during insertion or withdrawal of the guidewire, force should not be applied to the guidewire and care should also be exercised when passing the tissue dilator over the guidewire. Clinicians should be aware of this rare complication and snare-loop technique could be considered as one of the methods for removal of the fractured guidewire.
format Online
Article
Text
id pubmed-3506858
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher The Korean Society of Anesthesiologists
record_format MEDLINE/PubMed
spelling pubmed-35068582012-11-29 Fracture of J-tipped guidewire during central venous catheterization and its successful removal under fluoroscopic guidance -A case report- Park, Sun Kyung Yi, In-Kyong Lee, Jae-Ho Kim, Dae-Hee Lee, Sook Young Korean J Anesthesiol Case Report Central venous catheterization by Seldinger's technique uses a guidewire which may cause complications such as kinking, knotting and fracture. Fractured guidewire may lead to severe outcomes such as embolization, and removal of it may also cause problems such as vessel damage. We experienced a case of right internal jugular venous catheterization complicated by guidewire fracture entrapped in the central venous catheter, and its successful removal under fluoroscopic guidance using snare-loop. The patient recovered without any complications. When resistance is felt during insertion or withdrawal of the guidewire, force should not be applied to the guidewire and care should also be exercised when passing the tissue dilator over the guidewire. Clinicians should be aware of this rare complication and snare-loop technique could be considered as one of the methods for removal of the fractured guidewire. The Korean Society of Anesthesiologists 2012-11 2012-11-16 /pmc/articles/PMC3506858/ /pubmed/23198042 http://dx.doi.org/10.4097/kjae.2012.63.5.457 Text en Copyright © the Korean Society of Anesthesiologists, 2012 http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Park, Sun Kyung
Yi, In-Kyong
Lee, Jae-Ho
Kim, Dae-Hee
Lee, Sook Young
Fracture of J-tipped guidewire during central venous catheterization and its successful removal under fluoroscopic guidance -A case report-
title Fracture of J-tipped guidewire during central venous catheterization and its successful removal under fluoroscopic guidance -A case report-
title_full Fracture of J-tipped guidewire during central venous catheterization and its successful removal under fluoroscopic guidance -A case report-
title_fullStr Fracture of J-tipped guidewire during central venous catheterization and its successful removal under fluoroscopic guidance -A case report-
title_full_unstemmed Fracture of J-tipped guidewire during central venous catheterization and its successful removal under fluoroscopic guidance -A case report-
title_short Fracture of J-tipped guidewire during central venous catheterization and its successful removal under fluoroscopic guidance -A case report-
title_sort fracture of j-tipped guidewire during central venous catheterization and its successful removal under fluoroscopic guidance -a case report-
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3506858/
https://www.ncbi.nlm.nih.gov/pubmed/23198042
http://dx.doi.org/10.4097/kjae.2012.63.5.457
work_keys_str_mv AT parksunkyung fractureofjtippedguidewireduringcentralvenouscatheterizationanditssuccessfulremovalunderfluoroscopicguidanceacasereport
AT yiinkyong fractureofjtippedguidewireduringcentralvenouscatheterizationanditssuccessfulremovalunderfluoroscopicguidanceacasereport
AT leejaeho fractureofjtippedguidewireduringcentralvenouscatheterizationanditssuccessfulremovalunderfluoroscopicguidanceacasereport
AT kimdaehee fractureofjtippedguidewireduringcentralvenouscatheterizationanditssuccessfulremovalunderfluoroscopicguidanceacasereport
AT leesookyoung fractureofjtippedguidewireduringcentralvenouscatheterizationanditssuccessfulremovalunderfluoroscopicguidanceacasereport