Fracture of J-tipped guidewire during central venous catheterization and its successful removal under fluoroscopic guidance -A case report-
Central venous catheterization by Seldinger's technique uses a guidewire which may cause complications such as kinking, knotting and fracture. Fractured guidewire may lead to severe outcomes such as embolization, and removal of it may also cause problems such as vessel damage. We experienced a...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Anesthesiologists
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3506858/ https://www.ncbi.nlm.nih.gov/pubmed/23198042 http://dx.doi.org/10.4097/kjae.2012.63.5.457 |
_version_ | 1782250965939781632 |
---|---|
author | Park, Sun Kyung Yi, In-Kyong Lee, Jae-Ho Kim, Dae-Hee Lee, Sook Young |
author_facet | Park, Sun Kyung Yi, In-Kyong Lee, Jae-Ho Kim, Dae-Hee Lee, Sook Young |
author_sort | Park, Sun Kyung |
collection | PubMed |
description | Central venous catheterization by Seldinger's technique uses a guidewire which may cause complications such as kinking, knotting and fracture. Fractured guidewire may lead to severe outcomes such as embolization, and removal of it may also cause problems such as vessel damage. We experienced a case of right internal jugular venous catheterization complicated by guidewire fracture entrapped in the central venous catheter, and its successful removal under fluoroscopic guidance using snare-loop. The patient recovered without any complications. When resistance is felt during insertion or withdrawal of the guidewire, force should not be applied to the guidewire and care should also be exercised when passing the tissue dilator over the guidewire. Clinicians should be aware of this rare complication and snare-loop technique could be considered as one of the methods for removal of the fractured guidewire. |
format | Online Article Text |
id | pubmed-3506858 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | The Korean Society of Anesthesiologists |
record_format | MEDLINE/PubMed |
spelling | pubmed-35068582012-11-29 Fracture of J-tipped guidewire during central venous catheterization and its successful removal under fluoroscopic guidance -A case report- Park, Sun Kyung Yi, In-Kyong Lee, Jae-Ho Kim, Dae-Hee Lee, Sook Young Korean J Anesthesiol Case Report Central venous catheterization by Seldinger's technique uses a guidewire which may cause complications such as kinking, knotting and fracture. Fractured guidewire may lead to severe outcomes such as embolization, and removal of it may also cause problems such as vessel damage. We experienced a case of right internal jugular venous catheterization complicated by guidewire fracture entrapped in the central venous catheter, and its successful removal under fluoroscopic guidance using snare-loop. The patient recovered without any complications. When resistance is felt during insertion or withdrawal of the guidewire, force should not be applied to the guidewire and care should also be exercised when passing the tissue dilator over the guidewire. Clinicians should be aware of this rare complication and snare-loop technique could be considered as one of the methods for removal of the fractured guidewire. The Korean Society of Anesthesiologists 2012-11 2012-11-16 /pmc/articles/PMC3506858/ /pubmed/23198042 http://dx.doi.org/10.4097/kjae.2012.63.5.457 Text en Copyright © the Korean Society of Anesthesiologists, 2012 http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Park, Sun Kyung Yi, In-Kyong Lee, Jae-Ho Kim, Dae-Hee Lee, Sook Young Fracture of J-tipped guidewire during central venous catheterization and its successful removal under fluoroscopic guidance -A case report- |
title | Fracture of J-tipped guidewire during central venous catheterization and its successful removal under fluoroscopic guidance -A case report- |
title_full | Fracture of J-tipped guidewire during central venous catheterization and its successful removal under fluoroscopic guidance -A case report- |
title_fullStr | Fracture of J-tipped guidewire during central venous catheterization and its successful removal under fluoroscopic guidance -A case report- |
title_full_unstemmed | Fracture of J-tipped guidewire during central venous catheterization and its successful removal under fluoroscopic guidance -A case report- |
title_short | Fracture of J-tipped guidewire during central venous catheterization and its successful removal under fluoroscopic guidance -A case report- |
title_sort | fracture of j-tipped guidewire during central venous catheterization and its successful removal under fluoroscopic guidance -a case report- |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3506858/ https://www.ncbi.nlm.nih.gov/pubmed/23198042 http://dx.doi.org/10.4097/kjae.2012.63.5.457 |
work_keys_str_mv | AT parksunkyung fractureofjtippedguidewireduringcentralvenouscatheterizationanditssuccessfulremovalunderfluoroscopicguidanceacasereport AT yiinkyong fractureofjtippedguidewireduringcentralvenouscatheterizationanditssuccessfulremovalunderfluoroscopicguidanceacasereport AT leejaeho fractureofjtippedguidewireduringcentralvenouscatheterizationanditssuccessfulremovalunderfluoroscopicguidanceacasereport AT kimdaehee fractureofjtippedguidewireduringcentralvenouscatheterizationanditssuccessfulremovalunderfluoroscopicguidanceacasereport AT leesookyoung fractureofjtippedguidewireduringcentralvenouscatheterizationanditssuccessfulremovalunderfluoroscopicguidanceacasereport |