Cargando…
Development and Validation of HPTLC Method for Estimation of Tenoxicam and its Formulations
A simple, precise, accurate and rapid high performance thin layer chromatographic method has been developed and validated for the estimation of tenoxicam in the microemulsion gels. Tenoxicam was chromatographed on silica gel 60 F(254) TLC plate, as a stationary phase. The mobile phase was toluene: e...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3507343/ https://www.ncbi.nlm.nih.gov/pubmed/23204620 http://dx.doi.org/10.4103/0250-474X.102541 |
_version_ | 1782251062774726656 |
---|---|
author | Chandel, S. Barhate, C. R. Srivastava, A. R. Kulkarni, S. R. Kapadia, C. J. |
author_facet | Chandel, S. Barhate, C. R. Srivastava, A. R. Kulkarni, S. R. Kapadia, C. J. |
author_sort | Chandel, S. |
collection | PubMed |
description | A simple, precise, accurate and rapid high performance thin layer chromatographic method has been developed and validated for the estimation of tenoxicam in the microemulsion gels. Tenoxicam was chromatographed on silica gel 60 F(254) TLC plate, as a stationary phase. The mobile phase was toluene: ethyl acetate: formic acid (6:4:0.3 v/v/v), which gave a dense and compact spot of tenoxicam with a R(f) value of 0.38±0.03. The quantification was carried out at 379 nm. The method was validated in terms of linearity, accuracy, precision and specificity. To justify the suitability, accuracy and precision of the proposed method, recovery studies were performed at three concentration levels. Statistical analysis proved that the proposed method is accurate and reproducible with linearity in the range of 100 to 400 ng. The limit of detection and limit of quantification for tenoxicam were 25 and 50 μg/spot, respectively. The proposed method can be employed for the routine analysis of tenoxicam as well as in pharmaceutical formulations. |
format | Online Article Text |
id | pubmed-3507343 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-35073432012-11-30 Development and Validation of HPTLC Method for Estimation of Tenoxicam and its Formulations Chandel, S. Barhate, C. R. Srivastava, A. R. Kulkarni, S. R. Kapadia, C. J. Indian J Pharm Sci Research Paper A simple, precise, accurate and rapid high performance thin layer chromatographic method has been developed and validated for the estimation of tenoxicam in the microemulsion gels. Tenoxicam was chromatographed on silica gel 60 F(254) TLC plate, as a stationary phase. The mobile phase was toluene: ethyl acetate: formic acid (6:4:0.3 v/v/v), which gave a dense and compact spot of tenoxicam with a R(f) value of 0.38±0.03. The quantification was carried out at 379 nm. The method was validated in terms of linearity, accuracy, precision and specificity. To justify the suitability, accuracy and precision of the proposed method, recovery studies were performed at three concentration levels. Statistical analysis proved that the proposed method is accurate and reproducible with linearity in the range of 100 to 400 ng. The limit of detection and limit of quantification for tenoxicam were 25 and 50 μg/spot, respectively. The proposed method can be employed for the routine analysis of tenoxicam as well as in pharmaceutical formulations. Medknow Publications & Media Pvt Ltd 2012 /pmc/articles/PMC3507343/ /pubmed/23204620 http://dx.doi.org/10.4103/0250-474X.102541 Text en Copyright: © Indian Journal of Pharmaceutical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Paper Chandel, S. Barhate, C. R. Srivastava, A. R. Kulkarni, S. R. Kapadia, C. J. Development and Validation of HPTLC Method for Estimation of Tenoxicam and its Formulations |
title | Development and Validation of HPTLC Method for Estimation of Tenoxicam and its Formulations |
title_full | Development and Validation of HPTLC Method for Estimation of Tenoxicam and its Formulations |
title_fullStr | Development and Validation of HPTLC Method for Estimation of Tenoxicam and its Formulations |
title_full_unstemmed | Development and Validation of HPTLC Method for Estimation of Tenoxicam and its Formulations |
title_short | Development and Validation of HPTLC Method for Estimation of Tenoxicam and its Formulations |
title_sort | development and validation of hptlc method for estimation of tenoxicam and its formulations |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3507343/ https://www.ncbi.nlm.nih.gov/pubmed/23204620 http://dx.doi.org/10.4103/0250-474X.102541 |
work_keys_str_mv | AT chandels developmentandvalidationofhptlcmethodforestimationoftenoxicamanditsformulations AT barhatecr developmentandvalidationofhptlcmethodforestimationoftenoxicamanditsformulations AT srivastavaar developmentandvalidationofhptlcmethodforestimationoftenoxicamanditsformulations AT kulkarnisr developmentandvalidationofhptlcmethodforestimationoftenoxicamanditsformulations AT kapadiacj developmentandvalidationofhptlcmethodforestimationoftenoxicamanditsformulations |