Cargando…
7.0-T Magnetic Resonance Imaging Characterization of Acute Blood-Brain-Barrier Disruption Achieved with Intracranial Irreversible Electroporation
The blood-brain-barrier (BBB) presents a significant obstacle to the delivery of systemically administered chemotherapeutics for the treatment of brain cancer. Irreversible electroporation (IRE) is an emerging technology that uses pulsed electric fields for the non-thermal ablation of tumors. We hyp...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3511570/ https://www.ncbi.nlm.nih.gov/pubmed/23226293 http://dx.doi.org/10.1371/journal.pone.0050482 |
_version_ | 1782251639385620480 |
---|---|
author | Garcia, Paulo A. Rossmeisl, John H. Robertson, John L. Olson, John D. Johnson, Annette J. Ellis, Thomas L. Davalos, Rafael V. |
author_facet | Garcia, Paulo A. Rossmeisl, John H. Robertson, John L. Olson, John D. Johnson, Annette J. Ellis, Thomas L. Davalos, Rafael V. |
author_sort | Garcia, Paulo A. |
collection | PubMed |
description | The blood-brain-barrier (BBB) presents a significant obstacle to the delivery of systemically administered chemotherapeutics for the treatment of brain cancer. Irreversible electroporation (IRE) is an emerging technology that uses pulsed electric fields for the non-thermal ablation of tumors. We hypothesized that there is a minimal electric field at which BBB disruption occurs surrounding an IRE-induced zone of ablation and that this transient response can be measured using gadolinium (Gd) uptake as a surrogate marker for BBB disruption. The study was performed in a Good Laboratory Practices (GLP) compliant facility and had Institutional Animal Care and Use Committee (IACUC) approval. IRE ablations were performed in vivo in normal rat brain (n = 21) with 1-mm electrodes (0.45 mm diameter) separated by an edge-to-edge distance of 4 mm. We used an ECM830 pulse generator to deliver ninety 50-μs pulse treatments (0, 200, 400, 600, 800, and 1000 V/cm) at 1 Hz. The effects of applied electric fields and timing of Gd administration (−5, +5, +15, and +30 min) was assessed by systematically characterizing IRE-induced regions of cell death and BBB disruption with 7.0-T magnetic resonance imaging (MRI) and histopathologic evaluations. Statistical analysis on the effect of applied electric field and Gd timing was conducted via Fit of Least Squares with α = 0.05 and linear regression analysis. The focal nature of IRE treatment was confirmed with 3D MRI reconstructions with linear correlations between volume of ablation and electric field. Our results also demonstrated that IRE is an ablation technique that kills brain tissue in a focal manner depicted by MRI (n = 16) and transiently disrupts the BBB adjacent to the ablated area in a voltage-dependent manner as seen with Evan's Blue (n = 5) and Gd administration. |
format | Online Article Text |
id | pubmed-3511570 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-35115702012-12-05 7.0-T Magnetic Resonance Imaging Characterization of Acute Blood-Brain-Barrier Disruption Achieved with Intracranial Irreversible Electroporation Garcia, Paulo A. Rossmeisl, John H. Robertson, John L. Olson, John D. Johnson, Annette J. Ellis, Thomas L. Davalos, Rafael V. PLoS One Research Article The blood-brain-barrier (BBB) presents a significant obstacle to the delivery of systemically administered chemotherapeutics for the treatment of brain cancer. Irreversible electroporation (IRE) is an emerging technology that uses pulsed electric fields for the non-thermal ablation of tumors. We hypothesized that there is a minimal electric field at which BBB disruption occurs surrounding an IRE-induced zone of ablation and that this transient response can be measured using gadolinium (Gd) uptake as a surrogate marker for BBB disruption. The study was performed in a Good Laboratory Practices (GLP) compliant facility and had Institutional Animal Care and Use Committee (IACUC) approval. IRE ablations were performed in vivo in normal rat brain (n = 21) with 1-mm electrodes (0.45 mm diameter) separated by an edge-to-edge distance of 4 mm. We used an ECM830 pulse generator to deliver ninety 50-μs pulse treatments (0, 200, 400, 600, 800, and 1000 V/cm) at 1 Hz. The effects of applied electric fields and timing of Gd administration (−5, +5, +15, and +30 min) was assessed by systematically characterizing IRE-induced regions of cell death and BBB disruption with 7.0-T magnetic resonance imaging (MRI) and histopathologic evaluations. Statistical analysis on the effect of applied electric field and Gd timing was conducted via Fit of Least Squares with α = 0.05 and linear regression analysis. The focal nature of IRE treatment was confirmed with 3D MRI reconstructions with linear correlations between volume of ablation and electric field. Our results also demonstrated that IRE is an ablation technique that kills brain tissue in a focal manner depicted by MRI (n = 16) and transiently disrupts the BBB adjacent to the ablated area in a voltage-dependent manner as seen with Evan's Blue (n = 5) and Gd administration. Public Library of Science 2012-11-30 /pmc/articles/PMC3511570/ /pubmed/23226293 http://dx.doi.org/10.1371/journal.pone.0050482 Text en © 2012 Garcia et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Garcia, Paulo A. Rossmeisl, John H. Robertson, John L. Olson, John D. Johnson, Annette J. Ellis, Thomas L. Davalos, Rafael V. 7.0-T Magnetic Resonance Imaging Characterization of Acute Blood-Brain-Barrier Disruption Achieved with Intracranial Irreversible Electroporation |
title | 7.0-T Magnetic Resonance Imaging Characterization of Acute Blood-Brain-Barrier Disruption Achieved with Intracranial Irreversible Electroporation |
title_full | 7.0-T Magnetic Resonance Imaging Characterization of Acute Blood-Brain-Barrier Disruption Achieved with Intracranial Irreversible Electroporation |
title_fullStr | 7.0-T Magnetic Resonance Imaging Characterization of Acute Blood-Brain-Barrier Disruption Achieved with Intracranial Irreversible Electroporation |
title_full_unstemmed | 7.0-T Magnetic Resonance Imaging Characterization of Acute Blood-Brain-Barrier Disruption Achieved with Intracranial Irreversible Electroporation |
title_short | 7.0-T Magnetic Resonance Imaging Characterization of Acute Blood-Brain-Barrier Disruption Achieved with Intracranial Irreversible Electroporation |
title_sort | 7.0-t magnetic resonance imaging characterization of acute blood-brain-barrier disruption achieved with intracranial irreversible electroporation |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3511570/ https://www.ncbi.nlm.nih.gov/pubmed/23226293 http://dx.doi.org/10.1371/journal.pone.0050482 |
work_keys_str_mv | AT garciapauloa 70tmagneticresonanceimagingcharacterizationofacutebloodbrainbarrierdisruptionachievedwithintracranialirreversibleelectroporation AT rossmeisljohnh 70tmagneticresonanceimagingcharacterizationofacutebloodbrainbarrierdisruptionachievedwithintracranialirreversibleelectroporation AT robertsonjohnl 70tmagneticresonanceimagingcharacterizationofacutebloodbrainbarrierdisruptionachievedwithintracranialirreversibleelectroporation AT olsonjohnd 70tmagneticresonanceimagingcharacterizationofacutebloodbrainbarrierdisruptionachievedwithintracranialirreversibleelectroporation AT johnsonannettej 70tmagneticresonanceimagingcharacterizationofacutebloodbrainbarrierdisruptionachievedwithintracranialirreversibleelectroporation AT ellisthomasl 70tmagneticresonanceimagingcharacterizationofacutebloodbrainbarrierdisruptionachievedwithintracranialirreversibleelectroporation AT davalosrafaelv 70tmagneticresonanceimagingcharacterizationofacutebloodbrainbarrierdisruptionachievedwithintracranialirreversibleelectroporation |