Cargando…

Biomechanical stability of a supra-acetabular pedicle screw Internal Fixation device (INFIX) vs External Fixation and plates for vertically unstable pelvic fractures

BACKGROUND: We have recently developed a subcutaneous anterior pelvic fixation technique (INFIX). This internal fixator permits patients to sit, roll over in bed and lie on their sides without the cumbersome external appliances or their complications. The purpose of this study was to evaluate the bi...

Descripción completa

Detalles Bibliográficos
Autores principales: Vigdorchik, Jonathan M, Esquivel, Amanda O, Jin, Xin, Yang, King H, Onwudiwe, Ndidi A, Vaidya, Rahul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3511881/
https://www.ncbi.nlm.nih.gov/pubmed/23017093
http://dx.doi.org/10.1186/1749-799X-7-31
_version_ 1782251662171176960
author Vigdorchik, Jonathan M
Esquivel, Amanda O
Jin, Xin
Yang, King H
Onwudiwe, Ndidi A
Vaidya, Rahul
author_facet Vigdorchik, Jonathan M
Esquivel, Amanda O
Jin, Xin
Yang, King H
Onwudiwe, Ndidi A
Vaidya, Rahul
author_sort Vigdorchik, Jonathan M
collection PubMed
description BACKGROUND: We have recently developed a subcutaneous anterior pelvic fixation technique (INFIX). This internal fixator permits patients to sit, roll over in bed and lie on their sides without the cumbersome external appliances or their complications. The purpose of this study was to evaluate the biomechanical stability of this novel supraacetabular pedicle screw internal fixation construct (INFIX) and compare it to standard internal fixation and external fixation techniques in a single stance pelvic fracture model. METHODS: Nine synthetic pelves with a simulated anterior posterior compression type III injury were placed into three groups (External Fixator, INFIX and Internal Fixation). Displacement, total axial stiffness, and the stiffness at the pubic symphysis and SI joint were calculated. Displacement and stiffness were compared by ANOVA with a Bonferroni adjustment for multiple comparisons RESULTS: The mean displacement at the pubic symphysis was 20, 9 and 0.8 mm for external fixation, INFIX and internal fixation, respectively. Plate fixation was significantly stiffer than the INFIX and external Fixator (P = 0.01) at the symphysis pubis. The INFIX device was significantly stiffer than external fixation (P = 0.017) at the symphysis pubis. There was no significant difference in SI joint displacement between any of the groups. CONCLUSIONS: Anterior plate fixation is stiffer than both the INFIX and external fixation in single stance pelvic fracture model. The INFIX was stiffer than external fixation for both overall axial stiffness, and stiffness at the pubic symphysis. Combined with the presumed benefit of minimizing the complications associated with external fixation, the INFIX may be a more preferable option for temporary anterior pelvic fixation in situations where external fixation may have otherwise been used.
format Online
Article
Text
id pubmed-3511881
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-35118812012-12-03 Biomechanical stability of a supra-acetabular pedicle screw Internal Fixation device (INFIX) vs External Fixation and plates for vertically unstable pelvic fractures Vigdorchik, Jonathan M Esquivel, Amanda O Jin, Xin Yang, King H Onwudiwe, Ndidi A Vaidya, Rahul J Orthop Surg Res Research Article BACKGROUND: We have recently developed a subcutaneous anterior pelvic fixation technique (INFIX). This internal fixator permits patients to sit, roll over in bed and lie on their sides without the cumbersome external appliances or their complications. The purpose of this study was to evaluate the biomechanical stability of this novel supraacetabular pedicle screw internal fixation construct (INFIX) and compare it to standard internal fixation and external fixation techniques in a single stance pelvic fracture model. METHODS: Nine synthetic pelves with a simulated anterior posterior compression type III injury were placed into three groups (External Fixator, INFIX and Internal Fixation). Displacement, total axial stiffness, and the stiffness at the pubic symphysis and SI joint were calculated. Displacement and stiffness were compared by ANOVA with a Bonferroni adjustment for multiple comparisons RESULTS: The mean displacement at the pubic symphysis was 20, 9 and 0.8 mm for external fixation, INFIX and internal fixation, respectively. Plate fixation was significantly stiffer than the INFIX and external Fixator (P = 0.01) at the symphysis pubis. The INFIX device was significantly stiffer than external fixation (P = 0.017) at the symphysis pubis. There was no significant difference in SI joint displacement between any of the groups. CONCLUSIONS: Anterior plate fixation is stiffer than both the INFIX and external fixation in single stance pelvic fracture model. The INFIX was stiffer than external fixation for both overall axial stiffness, and stiffness at the pubic symphysis. Combined with the presumed benefit of minimizing the complications associated with external fixation, the INFIX may be a more preferable option for temporary anterior pelvic fixation in situations where external fixation may have otherwise been used. BioMed Central 2012-09-27 /pmc/articles/PMC3511881/ /pubmed/23017093 http://dx.doi.org/10.1186/1749-799X-7-31 Text en Copyright ©2012 Vigdorchik et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Vigdorchik, Jonathan M
Esquivel, Amanda O
Jin, Xin
Yang, King H
Onwudiwe, Ndidi A
Vaidya, Rahul
Biomechanical stability of a supra-acetabular pedicle screw Internal Fixation device (INFIX) vs External Fixation and plates for vertically unstable pelvic fractures
title Biomechanical stability of a supra-acetabular pedicle screw Internal Fixation device (INFIX) vs External Fixation and plates for vertically unstable pelvic fractures
title_full Biomechanical stability of a supra-acetabular pedicle screw Internal Fixation device (INFIX) vs External Fixation and plates for vertically unstable pelvic fractures
title_fullStr Biomechanical stability of a supra-acetabular pedicle screw Internal Fixation device (INFIX) vs External Fixation and plates for vertically unstable pelvic fractures
title_full_unstemmed Biomechanical stability of a supra-acetabular pedicle screw Internal Fixation device (INFIX) vs External Fixation and plates for vertically unstable pelvic fractures
title_short Biomechanical stability of a supra-acetabular pedicle screw Internal Fixation device (INFIX) vs External Fixation and plates for vertically unstable pelvic fractures
title_sort biomechanical stability of a supra-acetabular pedicle screw internal fixation device (infix) vs external fixation and plates for vertically unstable pelvic fractures
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3511881/
https://www.ncbi.nlm.nih.gov/pubmed/23017093
http://dx.doi.org/10.1186/1749-799X-7-31
work_keys_str_mv AT vigdorchikjonathanm biomechanicalstabilityofasupraacetabularpediclescrewinternalfixationdeviceinfixvsexternalfixationandplatesforverticallyunstablepelvicfractures
AT esquivelamandao biomechanicalstabilityofasupraacetabularpediclescrewinternalfixationdeviceinfixvsexternalfixationandplatesforverticallyunstablepelvicfractures
AT jinxin biomechanicalstabilityofasupraacetabularpediclescrewinternalfixationdeviceinfixvsexternalfixationandplatesforverticallyunstablepelvicfractures
AT yangkingh biomechanicalstabilityofasupraacetabularpediclescrewinternalfixationdeviceinfixvsexternalfixationandplatesforverticallyunstablepelvicfractures
AT onwudiwendidia biomechanicalstabilityofasupraacetabularpediclescrewinternalfixationdeviceinfixvsexternalfixationandplatesforverticallyunstablepelvicfractures
AT vaidyarahul biomechanicalstabilityofasupraacetabularpediclescrewinternalfixationdeviceinfixvsexternalfixationandplatesforverticallyunstablepelvicfractures