Biomechanical stability of a supra-acetabular pedicle screw Internal Fixation device (INFIX) vs External Fixation and plates for vertically unstable pelvic fractures
BACKGROUND: We have recently developed a subcutaneous anterior pelvic fixation technique (INFIX). This internal fixator permits patients to sit, roll over in bed and lie on their sides without the cumbersome external appliances or their complications. The purpose of this study was to evaluate the bi...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3511881/ https://www.ncbi.nlm.nih.gov/pubmed/23017093 http://dx.doi.org/10.1186/1749-799X-7-31 |
_version_ | 1782251662171176960 |
---|---|
author | Vigdorchik, Jonathan M Esquivel, Amanda O Jin, Xin Yang, King H Onwudiwe, Ndidi A Vaidya, Rahul |
author_facet | Vigdorchik, Jonathan M Esquivel, Amanda O Jin, Xin Yang, King H Onwudiwe, Ndidi A Vaidya, Rahul |
author_sort | Vigdorchik, Jonathan M |
collection | PubMed |
description | BACKGROUND: We have recently developed a subcutaneous anterior pelvic fixation technique (INFIX). This internal fixator permits patients to sit, roll over in bed and lie on their sides without the cumbersome external appliances or their complications. The purpose of this study was to evaluate the biomechanical stability of this novel supraacetabular pedicle screw internal fixation construct (INFIX) and compare it to standard internal fixation and external fixation techniques in a single stance pelvic fracture model. METHODS: Nine synthetic pelves with a simulated anterior posterior compression type III injury were placed into three groups (External Fixator, INFIX and Internal Fixation). Displacement, total axial stiffness, and the stiffness at the pubic symphysis and SI joint were calculated. Displacement and stiffness were compared by ANOVA with a Bonferroni adjustment for multiple comparisons RESULTS: The mean displacement at the pubic symphysis was 20, 9 and 0.8 mm for external fixation, INFIX and internal fixation, respectively. Plate fixation was significantly stiffer than the INFIX and external Fixator (P = 0.01) at the symphysis pubis. The INFIX device was significantly stiffer than external fixation (P = 0.017) at the symphysis pubis. There was no significant difference in SI joint displacement between any of the groups. CONCLUSIONS: Anterior plate fixation is stiffer than both the INFIX and external fixation in single stance pelvic fracture model. The INFIX was stiffer than external fixation for both overall axial stiffness, and stiffness at the pubic symphysis. Combined with the presumed benefit of minimizing the complications associated with external fixation, the INFIX may be a more preferable option for temporary anterior pelvic fixation in situations where external fixation may have otherwise been used. |
format | Online Article Text |
id | pubmed-3511881 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-35118812012-12-03 Biomechanical stability of a supra-acetabular pedicle screw Internal Fixation device (INFIX) vs External Fixation and plates for vertically unstable pelvic fractures Vigdorchik, Jonathan M Esquivel, Amanda O Jin, Xin Yang, King H Onwudiwe, Ndidi A Vaidya, Rahul J Orthop Surg Res Research Article BACKGROUND: We have recently developed a subcutaneous anterior pelvic fixation technique (INFIX). This internal fixator permits patients to sit, roll over in bed and lie on their sides without the cumbersome external appliances or their complications. The purpose of this study was to evaluate the biomechanical stability of this novel supraacetabular pedicle screw internal fixation construct (INFIX) and compare it to standard internal fixation and external fixation techniques in a single stance pelvic fracture model. METHODS: Nine synthetic pelves with a simulated anterior posterior compression type III injury were placed into three groups (External Fixator, INFIX and Internal Fixation). Displacement, total axial stiffness, and the stiffness at the pubic symphysis and SI joint were calculated. Displacement and stiffness were compared by ANOVA with a Bonferroni adjustment for multiple comparisons RESULTS: The mean displacement at the pubic symphysis was 20, 9 and 0.8 mm for external fixation, INFIX and internal fixation, respectively. Plate fixation was significantly stiffer than the INFIX and external Fixator (P = 0.01) at the symphysis pubis. The INFIX device was significantly stiffer than external fixation (P = 0.017) at the symphysis pubis. There was no significant difference in SI joint displacement between any of the groups. CONCLUSIONS: Anterior plate fixation is stiffer than both the INFIX and external fixation in single stance pelvic fracture model. The INFIX was stiffer than external fixation for both overall axial stiffness, and stiffness at the pubic symphysis. Combined with the presumed benefit of minimizing the complications associated with external fixation, the INFIX may be a more preferable option for temporary anterior pelvic fixation in situations where external fixation may have otherwise been used. BioMed Central 2012-09-27 /pmc/articles/PMC3511881/ /pubmed/23017093 http://dx.doi.org/10.1186/1749-799X-7-31 Text en Copyright ©2012 Vigdorchik et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Vigdorchik, Jonathan M Esquivel, Amanda O Jin, Xin Yang, King H Onwudiwe, Ndidi A Vaidya, Rahul Biomechanical stability of a supra-acetabular pedicle screw Internal Fixation device (INFIX) vs External Fixation and plates for vertically unstable pelvic fractures |
title | Biomechanical stability of a supra-acetabular pedicle screw Internal Fixation device (INFIX) vs External Fixation and plates for vertically unstable pelvic fractures |
title_full | Biomechanical stability of a supra-acetabular pedicle screw Internal Fixation device (INFIX) vs External Fixation and plates for vertically unstable pelvic fractures |
title_fullStr | Biomechanical stability of a supra-acetabular pedicle screw Internal Fixation device (INFIX) vs External Fixation and plates for vertically unstable pelvic fractures |
title_full_unstemmed | Biomechanical stability of a supra-acetabular pedicle screw Internal Fixation device (INFIX) vs External Fixation and plates for vertically unstable pelvic fractures |
title_short | Biomechanical stability of a supra-acetabular pedicle screw Internal Fixation device (INFIX) vs External Fixation and plates for vertically unstable pelvic fractures |
title_sort | biomechanical stability of a supra-acetabular pedicle screw internal fixation device (infix) vs external fixation and plates for vertically unstable pelvic fractures |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3511881/ https://www.ncbi.nlm.nih.gov/pubmed/23017093 http://dx.doi.org/10.1186/1749-799X-7-31 |
work_keys_str_mv | AT vigdorchikjonathanm biomechanicalstabilityofasupraacetabularpediclescrewinternalfixationdeviceinfixvsexternalfixationandplatesforverticallyunstablepelvicfractures AT esquivelamandao biomechanicalstabilityofasupraacetabularpediclescrewinternalfixationdeviceinfixvsexternalfixationandplatesforverticallyunstablepelvicfractures AT jinxin biomechanicalstabilityofasupraacetabularpediclescrewinternalfixationdeviceinfixvsexternalfixationandplatesforverticallyunstablepelvicfractures AT yangkingh biomechanicalstabilityofasupraacetabularpediclescrewinternalfixationdeviceinfixvsexternalfixationandplatesforverticallyunstablepelvicfractures AT onwudiwendidia biomechanicalstabilityofasupraacetabularpediclescrewinternalfixationdeviceinfixvsexternalfixationandplatesforverticallyunstablepelvicfractures AT vaidyarahul biomechanicalstabilityofasupraacetabularpediclescrewinternalfixationdeviceinfixvsexternalfixationandplatesforverticallyunstablepelvicfractures |