The Effect on Colon Visualization During Colonoscopy of the Addition of Simethicone to Polyethylene Glycol-Electrolyte Solution: A Randomized Single-Blind Study

OBJECTIVES: Colonic bubbles associated with polyethylene glycol-electrolyte solution (PEG-ELS) are common and obscure mucosal visualization. This study aimed to determine whether adding simethicone decreases the incidence of bubbles. METHODS: Prospective, single-blind, randomized comparison of split...

Descripción completa

Detalles Bibliográficos
Autores principales: Matro, Rebecca, Tupchong, Keegan, Daskalakis, Constantine, Gordon, Victoria, Katz, Leo, Kastenberg, David
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3513841/
https://www.ncbi.nlm.nih.gov/pubmed/23238113
http://dx.doi.org/10.1038/ctg.2012.16
_version_ 1782251940247240704
author Matro, Rebecca
Tupchong, Keegan
Daskalakis, Constantine
Gordon, Victoria
Katz, Leo
Kastenberg, David
author_facet Matro, Rebecca
Tupchong, Keegan
Daskalakis, Constantine
Gordon, Victoria
Katz, Leo
Kastenberg, David
author_sort Matro, Rebecca
collection PubMed
description OBJECTIVES: Colonic bubbles associated with polyethylene glycol-electrolyte solution (PEG-ELS) are common and obscure mucosal visualization. This study aimed to determine whether adding simethicone decreases the incidence of bubbles. METHODS: Prospective, single-blind, randomized comparison of split dose PEG-ELS vs. PEG-ELS+simethicone (PEG-S) for outpatient colonoscopy. Bubble severity for colonic segments was assessed on withdrawal as A=no/minimal bubbles, B=moderate bubbles/interfere with detecting 5 mm polyp, C=severe bubbles/interfere with detecting 10 mm polyp. Primary end point was Grade B or C bubbles in any colon segment. Secondary end points were cleansing quality, incidence and severity of side effects, and polyp detection. RESULTS: One hundred and thirty nine patients enrolled; 13 withdrew before colonoscopy. Of 123 patients evaluated, 62 took PEG-S and 61 PEG-ELS. The incidence of grade B or C bubbles was much lower with PEG-S compared with PEG-ELS (2% vs. 38% P=0.001). Overall cleansing (excellent or good) quality was not significantly different for either the whole colon (89% PEG-ELS, 94% of PEG-S, P=0.529) or right colon (88% PEG-ELS, 94% PEG-S, P=0.365). More PEG-S patients had excellent rather than good preps (whole colon 53% vs. 28%, P=0.004; right colon 53% vs. 35%, P=0.044). Need for any flushing was less with PEG-S (38% vs. 70%, P=0.001). The groups were not significantly different with respect to total procedure and withdrawal times, incidence or severity of side effects, or number of polyps/patient or adenomas/patient. CONCLUSIONS: Adding simethicone to PEG-ELS effectively eliminates bubbles, substantially reduces the need for flushing, and results in more excellent preparations.
format Online
Article
Text
id pubmed-3513841
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-35138412012-12-04 The Effect on Colon Visualization During Colonoscopy of the Addition of Simethicone to Polyethylene Glycol-Electrolyte Solution: A Randomized Single-Blind Study Matro, Rebecca Tupchong, Keegan Daskalakis, Constantine Gordon, Victoria Katz, Leo Kastenberg, David Clin Transl Gastroenterol Endoscopy OBJECTIVES: Colonic bubbles associated with polyethylene glycol-electrolyte solution (PEG-ELS) are common and obscure mucosal visualization. This study aimed to determine whether adding simethicone decreases the incidence of bubbles. METHODS: Prospective, single-blind, randomized comparison of split dose PEG-ELS vs. PEG-ELS+simethicone (PEG-S) for outpatient colonoscopy. Bubble severity for colonic segments was assessed on withdrawal as A=no/minimal bubbles, B=moderate bubbles/interfere with detecting 5 mm polyp, C=severe bubbles/interfere with detecting 10 mm polyp. Primary end point was Grade B or C bubbles in any colon segment. Secondary end points were cleansing quality, incidence and severity of side effects, and polyp detection. RESULTS: One hundred and thirty nine patients enrolled; 13 withdrew before colonoscopy. Of 123 patients evaluated, 62 took PEG-S and 61 PEG-ELS. The incidence of grade B or C bubbles was much lower with PEG-S compared with PEG-ELS (2% vs. 38% P=0.001). Overall cleansing (excellent or good) quality was not significantly different for either the whole colon (89% PEG-ELS, 94% of PEG-S, P=0.529) or right colon (88% PEG-ELS, 94% PEG-S, P=0.365). More PEG-S patients had excellent rather than good preps (whole colon 53% vs. 28%, P=0.004; right colon 53% vs. 35%, P=0.044). Need for any flushing was less with PEG-S (38% vs. 70%, P=0.001). The groups were not significantly different with respect to total procedure and withdrawal times, incidence or severity of side effects, or number of polyps/patient or adenomas/patient. CONCLUSIONS: Adding simethicone to PEG-ELS effectively eliminates bubbles, substantially reduces the need for flushing, and results in more excellent preparations. Nature Publishing Group 2012-11 2012-11-29 /pmc/articles/PMC3513841/ /pubmed/23238113 http://dx.doi.org/10.1038/ctg.2012.16 Text en Copyright © 2012 American College of Gastroenterology http://creativecommons.org/licenses/by-nc-nd/3.0/ This work is licensed under the Creative Commons Attribution-NonCommercial-No Derivative Works 3.0 Unported License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/3.0/
spellingShingle Endoscopy
Matro, Rebecca
Tupchong, Keegan
Daskalakis, Constantine
Gordon, Victoria
Katz, Leo
Kastenberg, David
The Effect on Colon Visualization During Colonoscopy of the Addition of Simethicone to Polyethylene Glycol-Electrolyte Solution: A Randomized Single-Blind Study
title The Effect on Colon Visualization During Colonoscopy of the Addition of Simethicone to Polyethylene Glycol-Electrolyte Solution: A Randomized Single-Blind Study
title_full The Effect on Colon Visualization During Colonoscopy of the Addition of Simethicone to Polyethylene Glycol-Electrolyte Solution: A Randomized Single-Blind Study
title_fullStr The Effect on Colon Visualization During Colonoscopy of the Addition of Simethicone to Polyethylene Glycol-Electrolyte Solution: A Randomized Single-Blind Study
title_full_unstemmed The Effect on Colon Visualization During Colonoscopy of the Addition of Simethicone to Polyethylene Glycol-Electrolyte Solution: A Randomized Single-Blind Study
title_short The Effect on Colon Visualization During Colonoscopy of the Addition of Simethicone to Polyethylene Glycol-Electrolyte Solution: A Randomized Single-Blind Study
title_sort effect on colon visualization during colonoscopy of the addition of simethicone to polyethylene glycol-electrolyte solution: a randomized single-blind study
topic Endoscopy
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3513841/
https://www.ncbi.nlm.nih.gov/pubmed/23238113
http://dx.doi.org/10.1038/ctg.2012.16
work_keys_str_mv AT matrorebecca theeffectoncolonvisualizationduringcolonoscopyoftheadditionofsimethiconetopolyethyleneglycolelectrolytesolutionarandomizedsingleblindstudy
AT tupchongkeegan theeffectoncolonvisualizationduringcolonoscopyoftheadditionofsimethiconetopolyethyleneglycolelectrolytesolutionarandomizedsingleblindstudy
AT daskalakisconstantine theeffectoncolonvisualizationduringcolonoscopyoftheadditionofsimethiconetopolyethyleneglycolelectrolytesolutionarandomizedsingleblindstudy
AT gordonvictoria theeffectoncolonvisualizationduringcolonoscopyoftheadditionofsimethiconetopolyethyleneglycolelectrolytesolutionarandomizedsingleblindstudy
AT katzleo theeffectoncolonvisualizationduringcolonoscopyoftheadditionofsimethiconetopolyethyleneglycolelectrolytesolutionarandomizedsingleblindstudy
AT kastenbergdavid theeffectoncolonvisualizationduringcolonoscopyoftheadditionofsimethiconetopolyethyleneglycolelectrolytesolutionarandomizedsingleblindstudy
AT matrorebecca effectoncolonvisualizationduringcolonoscopyoftheadditionofsimethiconetopolyethyleneglycolelectrolytesolutionarandomizedsingleblindstudy
AT tupchongkeegan effectoncolonvisualizationduringcolonoscopyoftheadditionofsimethiconetopolyethyleneglycolelectrolytesolutionarandomizedsingleblindstudy
AT daskalakisconstantine effectoncolonvisualizationduringcolonoscopyoftheadditionofsimethiconetopolyethyleneglycolelectrolytesolutionarandomizedsingleblindstudy
AT gordonvictoria effectoncolonvisualizationduringcolonoscopyoftheadditionofsimethiconetopolyethyleneglycolelectrolytesolutionarandomizedsingleblindstudy
AT katzleo effectoncolonvisualizationduringcolonoscopyoftheadditionofsimethiconetopolyethyleneglycolelectrolytesolutionarandomizedsingleblindstudy
AT kastenbergdavid effectoncolonvisualizationduringcolonoscopyoftheadditionofsimethiconetopolyethyleneglycolelectrolytesolutionarandomizedsingleblindstudy