Cargando…

One-Step Multiplex PCR Assay for Detecting Streptococcus pneumoniae Serogroups/Types Covered by 13-Valent Pneumococcal Conjugate Vaccine (PCV13)

The life-threatening illnesses caused by Streptococcus pneumoniae have been declined significantly after the use of pneumococcal conjugate vaccines. Continuous monitoring of the vaccine serogroups/types is necessary to follow the changing epidemiology of invasive pneumococcal diseases. Recently, the...

Descripción completa

Detalles Bibliográficos
Autores principales: Coskun-Ari, Fatma Filiz, Guldemir, Dilek, Durmaz, Riza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3514308/
https://www.ncbi.nlm.nih.gov/pubmed/23226519
http://dx.doi.org/10.1371/journal.pone.0050406
_version_ 1782252012947111936
author Coskun-Ari, Fatma Filiz
Guldemir, Dilek
Durmaz, Riza
author_facet Coskun-Ari, Fatma Filiz
Guldemir, Dilek
Durmaz, Riza
author_sort Coskun-Ari, Fatma Filiz
collection PubMed
description The life-threatening illnesses caused by Streptococcus pneumoniae have been declined significantly after the use of pneumococcal conjugate vaccines. Continuous monitoring of the vaccine serogroups/types is necessary to follow the changing epidemiology of invasive pneumococcal diseases. Recently, the sequential multiplex PCR approach, which uses several different sets of reactions, has been commonly adopted for determining capsular serogroups/types of S. pneumoniae isolates. In our study, we focused on development of a one-step multiplex PCR assay detecting all 1, 3, 4, 5, 6A/B, 7F, 9V, 14, 18C, 19A, 19F and 23F serogroups/types targeted by PCV13. The content of multiplex PCR mix and the cycling conditions were optimized in a manner that allowed rapid and accurate serotyping of a pneumococcal isolate by performing only a single amplification reaction. In our study of 182 clinical isolates, the one-step multiplex PCR assay exhibited 100% sensitivity and specificity, suggesting that its utilization can significantly reduce the use of traditional antiserum method requiring expensive reagents.
format Online
Article
Text
id pubmed-3514308
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-35143082012-12-05 One-Step Multiplex PCR Assay for Detecting Streptococcus pneumoniae Serogroups/Types Covered by 13-Valent Pneumococcal Conjugate Vaccine (PCV13) Coskun-Ari, Fatma Filiz Guldemir, Dilek Durmaz, Riza PLoS One Research Article The life-threatening illnesses caused by Streptococcus pneumoniae have been declined significantly after the use of pneumococcal conjugate vaccines. Continuous monitoring of the vaccine serogroups/types is necessary to follow the changing epidemiology of invasive pneumococcal diseases. Recently, the sequential multiplex PCR approach, which uses several different sets of reactions, has been commonly adopted for determining capsular serogroups/types of S. pneumoniae isolates. In our study, we focused on development of a one-step multiplex PCR assay detecting all 1, 3, 4, 5, 6A/B, 7F, 9V, 14, 18C, 19A, 19F and 23F serogroups/types targeted by PCV13. The content of multiplex PCR mix and the cycling conditions were optimized in a manner that allowed rapid and accurate serotyping of a pneumococcal isolate by performing only a single amplification reaction. In our study of 182 clinical isolates, the one-step multiplex PCR assay exhibited 100% sensitivity and specificity, suggesting that its utilization can significantly reduce the use of traditional antiserum method requiring expensive reagents. Public Library of Science 2012-12-04 /pmc/articles/PMC3514308/ /pubmed/23226519 http://dx.doi.org/10.1371/journal.pone.0050406 Text en © 2012 Coskun-Ari et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Coskun-Ari, Fatma Filiz
Guldemir, Dilek
Durmaz, Riza
One-Step Multiplex PCR Assay for Detecting Streptococcus pneumoniae Serogroups/Types Covered by 13-Valent Pneumococcal Conjugate Vaccine (PCV13)
title One-Step Multiplex PCR Assay for Detecting Streptococcus pneumoniae Serogroups/Types Covered by 13-Valent Pneumococcal Conjugate Vaccine (PCV13)
title_full One-Step Multiplex PCR Assay for Detecting Streptococcus pneumoniae Serogroups/Types Covered by 13-Valent Pneumococcal Conjugate Vaccine (PCV13)
title_fullStr One-Step Multiplex PCR Assay for Detecting Streptococcus pneumoniae Serogroups/Types Covered by 13-Valent Pneumococcal Conjugate Vaccine (PCV13)
title_full_unstemmed One-Step Multiplex PCR Assay for Detecting Streptococcus pneumoniae Serogroups/Types Covered by 13-Valent Pneumococcal Conjugate Vaccine (PCV13)
title_short One-Step Multiplex PCR Assay for Detecting Streptococcus pneumoniae Serogroups/Types Covered by 13-Valent Pneumococcal Conjugate Vaccine (PCV13)
title_sort one-step multiplex pcr assay for detecting streptococcus pneumoniae serogroups/types covered by 13-valent pneumococcal conjugate vaccine (pcv13)
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3514308/
https://www.ncbi.nlm.nih.gov/pubmed/23226519
http://dx.doi.org/10.1371/journal.pone.0050406
work_keys_str_mv AT coskunarifatmafiliz onestepmultiplexpcrassayfordetectingstreptococcuspneumoniaeserogroupstypescoveredby13valentpneumococcalconjugatevaccinepcv13
AT guldemirdilek onestepmultiplexpcrassayfordetectingstreptococcuspneumoniaeserogroupstypescoveredby13valentpneumococcalconjugatevaccinepcv13
AT durmazriza onestepmultiplexpcrassayfordetectingstreptococcuspneumoniaeserogroupstypescoveredby13valentpneumococcalconjugatevaccinepcv13