Cargando…

Analysis of Vocal Fold Function From Acoustic Data Simultaneously Recorded With High-Speed Endoscopy

SUMMARY: Acoustic and endoscopic voice assessments are routinely performed to determine the vocal fold vibratory function as part of the voice assessment protocol in clinics. More often than not these data are separately recorded, resulting in information being obtained from two different phonation...

Descripción completa

Detalles Bibliográficos
Autores principales: Döllinger, Michael, Kunduk, Melda, Kaltenbacher, Manfred, Vondenhoff, Sabine, Ziethe, Anke, Eysholdt, Ulrich, Bohr, Christopher
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Mosby 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3514632/
https://www.ncbi.nlm.nih.gov/pubmed/22632795
http://dx.doi.org/10.1016/j.jvoice.2012.02.001
_version_ 1782252055563337728
author Döllinger, Michael
Kunduk, Melda
Kaltenbacher, Manfred
Vondenhoff, Sabine
Ziethe, Anke
Eysholdt, Ulrich
Bohr, Christopher
author_facet Döllinger, Michael
Kunduk, Melda
Kaltenbacher, Manfred
Vondenhoff, Sabine
Ziethe, Anke
Eysholdt, Ulrich
Bohr, Christopher
author_sort Döllinger, Michael
collection PubMed
description SUMMARY: Acoustic and endoscopic voice assessments are routinely performed to determine the vocal fold vibratory function as part of the voice assessment protocol in clinics. More often than not these data are separately recorded, resulting in information being obtained from two different phonation segments and an increase of time for the voice evaluation process. This study explores the use of acoustic data, simultaneously recorded during high-speed endoscopy (HSE), for the evaluation of vocal fold function. PATIENTS AND METHODS: HSE and acoustic data were recorded from the subjects simultaneously during sustained phonation. The data included voices of 73 healthy subjects, 148 paresis, 210 functional dysphonias, and 119 benign lesions of vocal folds. For this study, only acoustic data were analyzed using Dr. Speech software (Tiger electronics Inc., MA). Twelve parameters were computed; 82% of the acoustic voice recordings could be analyzed. Statistical analysis was performed with SPSS 17.0. RESULTS: Acoustic data was easily recorded simultaneously allowing analyses of the same phonation segment to determine vocal fold function and therefore eliminating the need for another voice recording. The acoustic voice parameters differed between genders in the healthy voice group. Most of the parameters showed significant differences between healthy and pathological groups. CONCLUSION: Simultaneously recorded endoscopic and acoustic data is valuable. Differentiation between healthy and pathological groups was possible using acoustic data only. We suggest that the synchronously recorded acoustic signal is of sufficient quality for objective analysis yielding reduced examination time.
format Online
Article
Text
id pubmed-3514632
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Mosby
record_format MEDLINE/PubMed
spelling pubmed-35146322012-12-21 Analysis of Vocal Fold Function From Acoustic Data Simultaneously Recorded With High-Speed Endoscopy Döllinger, Michael Kunduk, Melda Kaltenbacher, Manfred Vondenhoff, Sabine Ziethe, Anke Eysholdt, Ulrich Bohr, Christopher J Voice Article SUMMARY: Acoustic and endoscopic voice assessments are routinely performed to determine the vocal fold vibratory function as part of the voice assessment protocol in clinics. More often than not these data are separately recorded, resulting in information being obtained from two different phonation segments and an increase of time for the voice evaluation process. This study explores the use of acoustic data, simultaneously recorded during high-speed endoscopy (HSE), for the evaluation of vocal fold function. PATIENTS AND METHODS: HSE and acoustic data were recorded from the subjects simultaneously during sustained phonation. The data included voices of 73 healthy subjects, 148 paresis, 210 functional dysphonias, and 119 benign lesions of vocal folds. For this study, only acoustic data were analyzed using Dr. Speech software (Tiger electronics Inc., MA). Twelve parameters were computed; 82% of the acoustic voice recordings could be analyzed. Statistical analysis was performed with SPSS 17.0. RESULTS: Acoustic data was easily recorded simultaneously allowing analyses of the same phonation segment to determine vocal fold function and therefore eliminating the need for another voice recording. The acoustic voice parameters differed between genders in the healthy voice group. Most of the parameters showed significant differences between healthy and pathological groups. CONCLUSION: Simultaneously recorded endoscopic and acoustic data is valuable. Differentiation between healthy and pathological groups was possible using acoustic data only. We suggest that the synchronously recorded acoustic signal is of sufficient quality for objective analysis yielding reduced examination time. Mosby 2012-11 /pmc/articles/PMC3514632/ /pubmed/22632795 http://dx.doi.org/10.1016/j.jvoice.2012.02.001 Text en © 2012 Mosby, Inc. https://creativecommons.org/licenses/by/4.0/ Open Access under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/) license
spellingShingle Article
Döllinger, Michael
Kunduk, Melda
Kaltenbacher, Manfred
Vondenhoff, Sabine
Ziethe, Anke
Eysholdt, Ulrich
Bohr, Christopher
Analysis of Vocal Fold Function From Acoustic Data Simultaneously Recorded With High-Speed Endoscopy
title Analysis of Vocal Fold Function From Acoustic Data Simultaneously Recorded With High-Speed Endoscopy
title_full Analysis of Vocal Fold Function From Acoustic Data Simultaneously Recorded With High-Speed Endoscopy
title_fullStr Analysis of Vocal Fold Function From Acoustic Data Simultaneously Recorded With High-Speed Endoscopy
title_full_unstemmed Analysis of Vocal Fold Function From Acoustic Data Simultaneously Recorded With High-Speed Endoscopy
title_short Analysis of Vocal Fold Function From Acoustic Data Simultaneously Recorded With High-Speed Endoscopy
title_sort analysis of vocal fold function from acoustic data simultaneously recorded with high-speed endoscopy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3514632/
https://www.ncbi.nlm.nih.gov/pubmed/22632795
http://dx.doi.org/10.1016/j.jvoice.2012.02.001
work_keys_str_mv AT dollingermichael analysisofvocalfoldfunctionfromacousticdatasimultaneouslyrecordedwithhighspeedendoscopy
AT kundukmelda analysisofvocalfoldfunctionfromacousticdatasimultaneouslyrecordedwithhighspeedendoscopy
AT kaltenbachermanfred analysisofvocalfoldfunctionfromacousticdatasimultaneouslyrecordedwithhighspeedendoscopy
AT vondenhoffsabine analysisofvocalfoldfunctionfromacousticdatasimultaneouslyrecordedwithhighspeedendoscopy
AT zietheanke analysisofvocalfoldfunctionfromacousticdatasimultaneouslyrecordedwithhighspeedendoscopy
AT eysholdtulrich analysisofvocalfoldfunctionfromacousticdatasimultaneouslyrecordedwithhighspeedendoscopy
AT bohrchristopher analysisofvocalfoldfunctionfromacousticdatasimultaneouslyrecordedwithhighspeedendoscopy