Cargando…
Analysis of Vocal Fold Function From Acoustic Data Simultaneously Recorded With High-Speed Endoscopy
SUMMARY: Acoustic and endoscopic voice assessments are routinely performed to determine the vocal fold vibratory function as part of the voice assessment protocol in clinics. More often than not these data are separately recorded, resulting in information being obtained from two different phonation...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Mosby
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3514632/ https://www.ncbi.nlm.nih.gov/pubmed/22632795 http://dx.doi.org/10.1016/j.jvoice.2012.02.001 |
_version_ | 1782252055563337728 |
---|---|
author | Döllinger, Michael Kunduk, Melda Kaltenbacher, Manfred Vondenhoff, Sabine Ziethe, Anke Eysholdt, Ulrich Bohr, Christopher |
author_facet | Döllinger, Michael Kunduk, Melda Kaltenbacher, Manfred Vondenhoff, Sabine Ziethe, Anke Eysholdt, Ulrich Bohr, Christopher |
author_sort | Döllinger, Michael |
collection | PubMed |
description | SUMMARY: Acoustic and endoscopic voice assessments are routinely performed to determine the vocal fold vibratory function as part of the voice assessment protocol in clinics. More often than not these data are separately recorded, resulting in information being obtained from two different phonation segments and an increase of time for the voice evaluation process. This study explores the use of acoustic data, simultaneously recorded during high-speed endoscopy (HSE), for the evaluation of vocal fold function. PATIENTS AND METHODS: HSE and acoustic data were recorded from the subjects simultaneously during sustained phonation. The data included voices of 73 healthy subjects, 148 paresis, 210 functional dysphonias, and 119 benign lesions of vocal folds. For this study, only acoustic data were analyzed using Dr. Speech software (Tiger electronics Inc., MA). Twelve parameters were computed; 82% of the acoustic voice recordings could be analyzed. Statistical analysis was performed with SPSS 17.0. RESULTS: Acoustic data was easily recorded simultaneously allowing analyses of the same phonation segment to determine vocal fold function and therefore eliminating the need for another voice recording. The acoustic voice parameters differed between genders in the healthy voice group. Most of the parameters showed significant differences between healthy and pathological groups. CONCLUSION: Simultaneously recorded endoscopic and acoustic data is valuable. Differentiation between healthy and pathological groups was possible using acoustic data only. We suggest that the synchronously recorded acoustic signal is of sufficient quality for objective analysis yielding reduced examination time. |
format | Online Article Text |
id | pubmed-3514632 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Mosby |
record_format | MEDLINE/PubMed |
spelling | pubmed-35146322012-12-21 Analysis of Vocal Fold Function From Acoustic Data Simultaneously Recorded With High-Speed Endoscopy Döllinger, Michael Kunduk, Melda Kaltenbacher, Manfred Vondenhoff, Sabine Ziethe, Anke Eysholdt, Ulrich Bohr, Christopher J Voice Article SUMMARY: Acoustic and endoscopic voice assessments are routinely performed to determine the vocal fold vibratory function as part of the voice assessment protocol in clinics. More often than not these data are separately recorded, resulting in information being obtained from two different phonation segments and an increase of time for the voice evaluation process. This study explores the use of acoustic data, simultaneously recorded during high-speed endoscopy (HSE), for the evaluation of vocal fold function. PATIENTS AND METHODS: HSE and acoustic data were recorded from the subjects simultaneously during sustained phonation. The data included voices of 73 healthy subjects, 148 paresis, 210 functional dysphonias, and 119 benign lesions of vocal folds. For this study, only acoustic data were analyzed using Dr. Speech software (Tiger electronics Inc., MA). Twelve parameters were computed; 82% of the acoustic voice recordings could be analyzed. Statistical analysis was performed with SPSS 17.0. RESULTS: Acoustic data was easily recorded simultaneously allowing analyses of the same phonation segment to determine vocal fold function and therefore eliminating the need for another voice recording. The acoustic voice parameters differed between genders in the healthy voice group. Most of the parameters showed significant differences between healthy and pathological groups. CONCLUSION: Simultaneously recorded endoscopic and acoustic data is valuable. Differentiation between healthy and pathological groups was possible using acoustic data only. We suggest that the synchronously recorded acoustic signal is of sufficient quality for objective analysis yielding reduced examination time. Mosby 2012-11 /pmc/articles/PMC3514632/ /pubmed/22632795 http://dx.doi.org/10.1016/j.jvoice.2012.02.001 Text en © 2012 Mosby, Inc. https://creativecommons.org/licenses/by/4.0/ Open Access under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/) license |
spellingShingle | Article Döllinger, Michael Kunduk, Melda Kaltenbacher, Manfred Vondenhoff, Sabine Ziethe, Anke Eysholdt, Ulrich Bohr, Christopher Analysis of Vocal Fold Function From Acoustic Data Simultaneously Recorded With High-Speed Endoscopy |
title | Analysis of Vocal Fold Function From Acoustic Data Simultaneously Recorded With High-Speed Endoscopy |
title_full | Analysis of Vocal Fold Function From Acoustic Data Simultaneously Recorded With High-Speed Endoscopy |
title_fullStr | Analysis of Vocal Fold Function From Acoustic Data Simultaneously Recorded With High-Speed Endoscopy |
title_full_unstemmed | Analysis of Vocal Fold Function From Acoustic Data Simultaneously Recorded With High-Speed Endoscopy |
title_short | Analysis of Vocal Fold Function From Acoustic Data Simultaneously Recorded With High-Speed Endoscopy |
title_sort | analysis of vocal fold function from acoustic data simultaneously recorded with high-speed endoscopy |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3514632/ https://www.ncbi.nlm.nih.gov/pubmed/22632795 http://dx.doi.org/10.1016/j.jvoice.2012.02.001 |
work_keys_str_mv | AT dollingermichael analysisofvocalfoldfunctionfromacousticdatasimultaneouslyrecordedwithhighspeedendoscopy AT kundukmelda analysisofvocalfoldfunctionfromacousticdatasimultaneouslyrecordedwithhighspeedendoscopy AT kaltenbachermanfred analysisofvocalfoldfunctionfromacousticdatasimultaneouslyrecordedwithhighspeedendoscopy AT vondenhoffsabine analysisofvocalfoldfunctionfromacousticdatasimultaneouslyrecordedwithhighspeedendoscopy AT zietheanke analysisofvocalfoldfunctionfromacousticdatasimultaneouslyrecordedwithhighspeedendoscopy AT eysholdtulrich analysisofvocalfoldfunctionfromacousticdatasimultaneouslyrecordedwithhighspeedendoscopy AT bohrchristopher analysisofvocalfoldfunctionfromacousticdatasimultaneouslyrecordedwithhighspeedendoscopy |