Cargando…

A method for determination of muscle fiber diameter using single fiber potential (SFP) analysis

We have used computer simulation to study the relationship between the muscle fiber diameter and parameters: peak-to-peak amplitude and duration of the negative peak of the muscle fiber action potential. We found that the negative peak duration is useful in the determination of fiber diameter via th...

Descripción completa

Detalles Bibliográficos
Autores principales: Zalewska, Ewa, Nandedkar, Sanjeev D., Hausmanowa-Petrusewicz, Irena
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer-Verlag 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3514689/
https://www.ncbi.nlm.nih.gov/pubmed/23054382
http://dx.doi.org/10.1007/s11517-012-0965-x
_version_ 1782252063991791616
author Zalewska, Ewa
Nandedkar, Sanjeev D.
Hausmanowa-Petrusewicz, Irena
author_facet Zalewska, Ewa
Nandedkar, Sanjeev D.
Hausmanowa-Petrusewicz, Irena
author_sort Zalewska, Ewa
collection PubMed
description We have used computer simulation to study the relationship between the muscle fiber diameter and parameters: peak-to-peak amplitude and duration of the negative peak of the muscle fiber action potential. We found that the negative peak duration is useful in the determination of fiber diameter via the diameter dependence of conduction velocity. We have shown a direct link between the underlying physiology and the measurements characterizing single fiber potential. Using data from simulations, a graphical tool and an analytical method to estimate the muscle fiber diameter from the recorded action potential has been developed. The ability to quantify the fiber diameter can add significantly to the single fiber electromyography examination. It may help study of muscle fiber diameter variability and thus compliment the muscle biopsy studies.
format Online
Article
Text
id pubmed-3514689
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-35146892012-12-05 A method for determination of muscle fiber diameter using single fiber potential (SFP) analysis Zalewska, Ewa Nandedkar, Sanjeev D. Hausmanowa-Petrusewicz, Irena Med Biol Eng Comput Original Article We have used computer simulation to study the relationship between the muscle fiber diameter and parameters: peak-to-peak amplitude and duration of the negative peak of the muscle fiber action potential. We found that the negative peak duration is useful in the determination of fiber diameter via the diameter dependence of conduction velocity. We have shown a direct link between the underlying physiology and the measurements characterizing single fiber potential. Using data from simulations, a graphical tool and an analytical method to estimate the muscle fiber diameter from the recorded action potential has been developed. The ability to quantify the fiber diameter can add significantly to the single fiber electromyography examination. It may help study of muscle fiber diameter variability and thus compliment the muscle biopsy studies. Springer-Verlag 2012-10-05 2012 /pmc/articles/PMC3514689/ /pubmed/23054382 http://dx.doi.org/10.1007/s11517-012-0965-x Text en © The Author(s) 2012 https://creativecommons.org/licenses/by/4.0/ This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Original Article
Zalewska, Ewa
Nandedkar, Sanjeev D.
Hausmanowa-Petrusewicz, Irena
A method for determination of muscle fiber diameter using single fiber potential (SFP) analysis
title A method for determination of muscle fiber diameter using single fiber potential (SFP) analysis
title_full A method for determination of muscle fiber diameter using single fiber potential (SFP) analysis
title_fullStr A method for determination of muscle fiber diameter using single fiber potential (SFP) analysis
title_full_unstemmed A method for determination of muscle fiber diameter using single fiber potential (SFP) analysis
title_short A method for determination of muscle fiber diameter using single fiber potential (SFP) analysis
title_sort method for determination of muscle fiber diameter using single fiber potential (sfp) analysis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3514689/
https://www.ncbi.nlm.nih.gov/pubmed/23054382
http://dx.doi.org/10.1007/s11517-012-0965-x
work_keys_str_mv AT zalewskaewa amethodfordeterminationofmusclefiberdiameterusingsinglefiberpotentialsfpanalysis
AT nandedkarsanjeevd amethodfordeterminationofmusclefiberdiameterusingsinglefiberpotentialsfpanalysis
AT hausmanowapetrusewiczirena amethodfordeterminationofmusclefiberdiameterusingsinglefiberpotentialsfpanalysis
AT zalewskaewa methodfordeterminationofmusclefiberdiameterusingsinglefiberpotentialsfpanalysis
AT nandedkarsanjeevd methodfordeterminationofmusclefiberdiameterusingsinglefiberpotentialsfpanalysis
AT hausmanowapetrusewiczirena methodfordeterminationofmusclefiberdiameterusingsinglefiberpotentialsfpanalysis