Cargando…

Ultrasound-Mediated Gene Delivery with Cationic Versus Neutral Microbubbles: Effect of DNA and Microbubble Dose on In Vivo Transfection Efficiency

Objective: To assess the effect of varying microbubble (MB) and DNA doses on the overall and comparative efficiencies of ultrasound (US)-mediated gene delivery (UMGD) to murine hindlimb skeletal muscle using cationic versus neutral MBs. Materials and Methods: Cationic and control neutral MBs were ch...

Descripción completa

Detalles Bibliográficos
Autores principales: Panje, Cedric M., Wang, David S., Pysz, Marybeth A., Paulmurugan, Ramasamy, Ren, Ying, Tranquart, Francois, Tian, Lu, Willmann, Jürgen K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Ivyspring International Publisher 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3516840/
https://www.ncbi.nlm.nih.gov/pubmed/23227124
http://dx.doi.org/10.7150/thno.4240
_version_ 1782252351672811520
author Panje, Cedric M.
Wang, David S.
Pysz, Marybeth A.
Paulmurugan, Ramasamy
Ren, Ying
Tranquart, Francois
Tian, Lu
Willmann, Jürgen K.
author_facet Panje, Cedric M.
Wang, David S.
Pysz, Marybeth A.
Paulmurugan, Ramasamy
Ren, Ying
Tranquart, Francois
Tian, Lu
Willmann, Jürgen K.
author_sort Panje, Cedric M.
collection PubMed
description Objective: To assess the effect of varying microbubble (MB) and DNA doses on the overall and comparative efficiencies of ultrasound (US)-mediated gene delivery (UMGD) to murine hindlimb skeletal muscle using cationic versus neutral MBs. Materials and Methods: Cationic and control neutral MBs were characterized for size, charge, plasmid DNA binding, and ability to protect DNA against endonuclease degradation. UMGD of a codon optimized firefly luciferase (Fluc) reporter plasmid to endothelial cells (1 MHz, 1 W/cm², 20% duty cycle, 1 min) was performed in cell culture using cationic, neutral, or no MBs. In vivo UMGD to mouse hindlimb muscle was performed by insonation (1 MHz, 2 W/cm², 50% duty cycle, 5 min) after intravenous administration of Fluc combined with cationic, neutral, or no MBs. Gene delivery efficiency was assessed by serial in vivo bioluminescence imaging. Efficiency of in vivo UMGD with cationic versus neutral MBs was systematically evaluated by varying plasmid DNA dose (10, 17.5, 25, 37.5, and 50 µg) while maintaining a constant MB dose of 1x10(8) MBs and by changing MB dose (1x10(7), 5x10(7), 1x10(8), or 5x10(8) MBs) while keeping a constant DNA dose of 50 µg. Results: Cationic and size-matched control neutral MBs differed significantly in zeta potential with cationic MBs being able to bind plasmid DNA (binding capacity of 0.03 pg/MB) and partially protect DNA from nuclease degradation while neutral MBs could not. Cationic MBs enhanced UMGD compared to neutral MBs as well as no MB and no US controls both in cell culture (P < 0.001) and in vivo (P < 0.05). Regardless of MB type, in vivo UMGD efficiency increased dose-dependently with DNA dose and showed overall maximum transfection with 50 µg DNA. However, there was an inverse correlation (ρ = -0.90; P = 0.02) between DNA dose and the degree of enhanced UMGD efficiency observed with using cationic MBs instead of neutral MBs. The delivery efficiency advantage associated with cationic MBs was most prominent at the lowest investigated DNA dose (7.5-fold increase with cationic versus neutral MBs at a DNA dose of 10 µg; P = 0.02) compared to only a 1.4-fold increase at a DNA dose of 50 µg (P < 0.01). With increasing MB dose, overall in vivo UMGD efficiency increased dose-dependently with a maximum reached at a dose of 1x10(8) MBs with no further significant increase with 5x10(8) MBs (P = 0.97). However, compared to neutral MBs, cationic MBs enhanced UMGD efficiency the most at low MB doses. Relative enhancement of UMGD efficiency using cationic over neutral MBs decreased from a factor of 27 for 1x10(7) MBs (P = 0.02) to a factor of 1.4 for 1x10(8) MBs (P < 0.01) and no significant difference for 5x10(8) MBs. Conclusions: Cationic MBs enhance UMGD to mouse skeletal muscle relative to neutral MBs but this is dependent on MB and DNA dose. The enhancement effect of cationic MBs on UMGD efficiency is more evident when lower doses of MBs or DNA are used, whereas the advantage of cationic MBs over neutral MBs is substantially reduced in the presence of excess MBs or DNA.
format Online
Article
Text
id pubmed-3516840
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Ivyspring International Publisher
record_format MEDLINE/PubMed
spelling pubmed-35168402012-12-07 Ultrasound-Mediated Gene Delivery with Cationic Versus Neutral Microbubbles: Effect of DNA and Microbubble Dose on In Vivo Transfection Efficiency Panje, Cedric M. Wang, David S. Pysz, Marybeth A. Paulmurugan, Ramasamy Ren, Ying Tranquart, Francois Tian, Lu Willmann, Jürgen K. Theranostics Research Paper Objective: To assess the effect of varying microbubble (MB) and DNA doses on the overall and comparative efficiencies of ultrasound (US)-mediated gene delivery (UMGD) to murine hindlimb skeletal muscle using cationic versus neutral MBs. Materials and Methods: Cationic and control neutral MBs were characterized for size, charge, plasmid DNA binding, and ability to protect DNA against endonuclease degradation. UMGD of a codon optimized firefly luciferase (Fluc) reporter plasmid to endothelial cells (1 MHz, 1 W/cm², 20% duty cycle, 1 min) was performed in cell culture using cationic, neutral, or no MBs. In vivo UMGD to mouse hindlimb muscle was performed by insonation (1 MHz, 2 W/cm², 50% duty cycle, 5 min) after intravenous administration of Fluc combined with cationic, neutral, or no MBs. Gene delivery efficiency was assessed by serial in vivo bioluminescence imaging. Efficiency of in vivo UMGD with cationic versus neutral MBs was systematically evaluated by varying plasmid DNA dose (10, 17.5, 25, 37.5, and 50 µg) while maintaining a constant MB dose of 1x10(8) MBs and by changing MB dose (1x10(7), 5x10(7), 1x10(8), or 5x10(8) MBs) while keeping a constant DNA dose of 50 µg. Results: Cationic and size-matched control neutral MBs differed significantly in zeta potential with cationic MBs being able to bind plasmid DNA (binding capacity of 0.03 pg/MB) and partially protect DNA from nuclease degradation while neutral MBs could not. Cationic MBs enhanced UMGD compared to neutral MBs as well as no MB and no US controls both in cell culture (P < 0.001) and in vivo (P < 0.05). Regardless of MB type, in vivo UMGD efficiency increased dose-dependently with DNA dose and showed overall maximum transfection with 50 µg DNA. However, there was an inverse correlation (ρ = -0.90; P = 0.02) between DNA dose and the degree of enhanced UMGD efficiency observed with using cationic MBs instead of neutral MBs. The delivery efficiency advantage associated with cationic MBs was most prominent at the lowest investigated DNA dose (7.5-fold increase with cationic versus neutral MBs at a DNA dose of 10 µg; P = 0.02) compared to only a 1.4-fold increase at a DNA dose of 50 µg (P < 0.01). With increasing MB dose, overall in vivo UMGD efficiency increased dose-dependently with a maximum reached at a dose of 1x10(8) MBs with no further significant increase with 5x10(8) MBs (P = 0.97). However, compared to neutral MBs, cationic MBs enhanced UMGD efficiency the most at low MB doses. Relative enhancement of UMGD efficiency using cationic over neutral MBs decreased from a factor of 27 for 1x10(7) MBs (P = 0.02) to a factor of 1.4 for 1x10(8) MBs (P < 0.01) and no significant difference for 5x10(8) MBs. Conclusions: Cationic MBs enhance UMGD to mouse skeletal muscle relative to neutral MBs but this is dependent on MB and DNA dose. The enhancement effect of cationic MBs on UMGD efficiency is more evident when lower doses of MBs or DNA are used, whereas the advantage of cationic MBs over neutral MBs is substantially reduced in the presence of excess MBs or DNA. Ivyspring International Publisher 2012-11-08 /pmc/articles/PMC3516840/ /pubmed/23227124 http://dx.doi.org/10.7150/thno.4240 Text en © Ivyspring International Publisher. This is an open-access article distributed under the terms of the Creative Commons License (http://creativecommons.org/licenses/by-nc-nd/3.0/). Reproduction is permitted for personal, noncommercial use, provided that the article is in whole, unmodified, and properly cited.
spellingShingle Research Paper
Panje, Cedric M.
Wang, David S.
Pysz, Marybeth A.
Paulmurugan, Ramasamy
Ren, Ying
Tranquart, Francois
Tian, Lu
Willmann, Jürgen K.
Ultrasound-Mediated Gene Delivery with Cationic Versus Neutral Microbubbles: Effect of DNA and Microbubble Dose on In Vivo Transfection Efficiency
title Ultrasound-Mediated Gene Delivery with Cationic Versus Neutral Microbubbles: Effect of DNA and Microbubble Dose on In Vivo Transfection Efficiency
title_full Ultrasound-Mediated Gene Delivery with Cationic Versus Neutral Microbubbles: Effect of DNA and Microbubble Dose on In Vivo Transfection Efficiency
title_fullStr Ultrasound-Mediated Gene Delivery with Cationic Versus Neutral Microbubbles: Effect of DNA and Microbubble Dose on In Vivo Transfection Efficiency
title_full_unstemmed Ultrasound-Mediated Gene Delivery with Cationic Versus Neutral Microbubbles: Effect of DNA and Microbubble Dose on In Vivo Transfection Efficiency
title_short Ultrasound-Mediated Gene Delivery with Cationic Versus Neutral Microbubbles: Effect of DNA and Microbubble Dose on In Vivo Transfection Efficiency
title_sort ultrasound-mediated gene delivery with cationic versus neutral microbubbles: effect of dna and microbubble dose on in vivo transfection efficiency
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3516840/
https://www.ncbi.nlm.nih.gov/pubmed/23227124
http://dx.doi.org/10.7150/thno.4240
work_keys_str_mv AT panjecedricm ultrasoundmediatedgenedeliverywithcationicversusneutralmicrobubbleseffectofdnaandmicrobubbledoseoninvivotransfectionefficiency
AT wangdavids ultrasoundmediatedgenedeliverywithcationicversusneutralmicrobubbleseffectofdnaandmicrobubbledoseoninvivotransfectionefficiency
AT pyszmarybetha ultrasoundmediatedgenedeliverywithcationicversusneutralmicrobubbleseffectofdnaandmicrobubbledoseoninvivotransfectionefficiency
AT paulmuruganramasamy ultrasoundmediatedgenedeliverywithcationicversusneutralmicrobubbleseffectofdnaandmicrobubbledoseoninvivotransfectionefficiency
AT renying ultrasoundmediatedgenedeliverywithcationicversusneutralmicrobubbleseffectofdnaandmicrobubbledoseoninvivotransfectionefficiency
AT tranquartfrancois ultrasoundmediatedgenedeliverywithcationicversusneutralmicrobubbleseffectofdnaandmicrobubbledoseoninvivotransfectionefficiency
AT tianlu ultrasoundmediatedgenedeliverywithcationicversusneutralmicrobubbleseffectofdnaandmicrobubbledoseoninvivotransfectionefficiency
AT willmannjurgenk ultrasoundmediatedgenedeliverywithcationicversusneutralmicrobubbleseffectofdnaandmicrobubbledoseoninvivotransfectionefficiency