Cargando…

Stereoscopic liver surface reconstruction

The paper presents a practical approach to measuring liver motion, both respiratory and laparoscopic, with a tool guided in the operating room. The presented method is based on standard operating room equipment, i.e. rigid laparoscopic cameras and a single incision laparoscopic surgery trocar. The t...

Descripción completa

Detalles Bibliográficos
Autores principales: Spinczyk, Dominik, Karwan, Adam, Rudnicki, Jerzy, Wróblewski, Tadeusz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3516990/
https://www.ncbi.nlm.nih.gov/pubmed/23256023
http://dx.doi.org/10.5114/wiitm.2011.28872
_version_ 1782252370603802624
author Spinczyk, Dominik
Karwan, Adam
Rudnicki, Jerzy
Wróblewski, Tadeusz
author_facet Spinczyk, Dominik
Karwan, Adam
Rudnicki, Jerzy
Wróblewski, Tadeusz
author_sort Spinczyk, Dominik
collection PubMed
description The paper presents a practical approach to measuring liver motion, both respiratory and laparoscopic, with a tool guided in the operating room. The presented method is based on standard operating room equipment, i.e. rigid laparoscopic cameras and a single incision laparoscopic surgery trocar. The triangulation algorithm is used and stereo correspondence points are marked manually by two independent experts. To calibrate the cameras two perpendicular chessboards, a pinhole camera model and a Tsai algorithm are used. The data set consists of twelve real liver surgery video sequences: ten open surgery and two laparoscopic, gathered from different patients. The setup equipment and methodology are presented. The proposed evaluation method based on both calibration points of the chessboard reconstruction and measurements made by the Polaris Vicra tracking system are used as a reference system. In the analysis stage we focused on two specific goals, measuring respiration and laparoscopic tool guided liver motions. We have presented separate examples for left and right liver lobes. It is possible to reconstruct liver motion using the SILS trocar. Our approach was made without additional position or movement sensors. Diffusion of cameras and laser for distance measurement seems to be less practical for in vivo laparoscopic data, but we do not exclude exploring such sensors in further research.
format Online
Article
Text
id pubmed-3516990
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-35169902012-12-19 Stereoscopic liver surface reconstruction Spinczyk, Dominik Karwan, Adam Rudnicki, Jerzy Wróblewski, Tadeusz Wideochir Inne Tech Maloinwazyjne Original Paper The paper presents a practical approach to measuring liver motion, both respiratory and laparoscopic, with a tool guided in the operating room. The presented method is based on standard operating room equipment, i.e. rigid laparoscopic cameras and a single incision laparoscopic surgery trocar. The triangulation algorithm is used and stereo correspondence points are marked manually by two independent experts. To calibrate the cameras two perpendicular chessboards, a pinhole camera model and a Tsai algorithm are used. The data set consists of twelve real liver surgery video sequences: ten open surgery and two laparoscopic, gathered from different patients. The setup equipment and methodology are presented. The proposed evaluation method based on both calibration points of the chessboard reconstruction and measurements made by the Polaris Vicra tracking system are used as a reference system. In the analysis stage we focused on two specific goals, measuring respiration and laparoscopic tool guided liver motions. We have presented separate examples for left and right liver lobes. It is possible to reconstruct liver motion using the SILS trocar. Our approach was made without additional position or movement sensors. Diffusion of cameras and laser for distance measurement seems to be less practical for in vivo laparoscopic data, but we do not exclude exploring such sensors in further research. Termedia Publishing House 2012-06-25 2012-08 /pmc/articles/PMC3516990/ /pubmed/23256023 http://dx.doi.org/10.5114/wiitm.2011.28872 Text en Copyright © 2012 Sekcja Wideochirurgii TChP http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Paper
Spinczyk, Dominik
Karwan, Adam
Rudnicki, Jerzy
Wróblewski, Tadeusz
Stereoscopic liver surface reconstruction
title Stereoscopic liver surface reconstruction
title_full Stereoscopic liver surface reconstruction
title_fullStr Stereoscopic liver surface reconstruction
title_full_unstemmed Stereoscopic liver surface reconstruction
title_short Stereoscopic liver surface reconstruction
title_sort stereoscopic liver surface reconstruction
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3516990/
https://www.ncbi.nlm.nih.gov/pubmed/23256023
http://dx.doi.org/10.5114/wiitm.2011.28872
work_keys_str_mv AT spinczykdominik stereoscopicliversurfacereconstruction
AT karwanadam stereoscopicliversurfacereconstruction
AT rudnickijerzy stereoscopicliversurfacereconstruction
AT wroblewskitadeusz stereoscopicliversurfacereconstruction