Cargando…

Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector CT: an anthropomorphic phantom study

OBJECTIVE: To assess the sensitivity of detection and accuracy of volumetry by manual and semi-automated quantification of artificial pulmonary nodules in an anthropomorphic thoracic phantom on low-dose CT. METHODS: Fifteen artificial spherical nodules (diameter 3, 5, 8, 10 and 12 mm; CT densities -...

Descripción completa

Detalles Bibliográficos
Autores principales: Xie, Xueqian, Zhao, Yingru, Snijder, Roland A., van Ooijen, Peter M. A., de Jong, Pim A., Oudkerk, Matthijs, de Bock, Geertruida H., Vliegenthart, Rozemarijn, Greuter, Marcel J. W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer-Verlag 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3517707/
https://www.ncbi.nlm.nih.gov/pubmed/22797957
http://dx.doi.org/10.1007/s00330-012-2570-7
_version_ 1782252463511830528
author Xie, Xueqian
Zhao, Yingru
Snijder, Roland A.
van Ooijen, Peter M. A.
de Jong, Pim A.
Oudkerk, Matthijs
de Bock, Geertruida H.
Vliegenthart, Rozemarijn
Greuter, Marcel J. W.
author_facet Xie, Xueqian
Zhao, Yingru
Snijder, Roland A.
van Ooijen, Peter M. A.
de Jong, Pim A.
Oudkerk, Matthijs
de Bock, Geertruida H.
Vliegenthart, Rozemarijn
Greuter, Marcel J. W.
author_sort Xie, Xueqian
collection PubMed
description OBJECTIVE: To assess the sensitivity of detection and accuracy of volumetry by manual and semi-automated quantification of artificial pulmonary nodules in an anthropomorphic thoracic phantom on low-dose CT. METHODS: Fifteen artificial spherical nodules (diameter 3, 5, 8, 10 and 12 mm; CT densities -800, -630 and +100 HU) were randomly placed inside an anthropomorphic thoracic phantom. The phantom was examined on 16- and 64-row multidetector CT with a low-dose protocol. Two independent blinded observers screened for pulmonary nodules. Nodule diameter was measured manually, and volume calculated. For solid nodules (+100 HU), diameter and volume were also evaluated by semi-automated software. Differences in observed volumes between the manual and semi-automated method were evaluated by a t-test. RESULTS: Sensitivity was 100 % for all nodules of >5 mm and larger, 60–80 % for solid and 0–20 % for non-solid 3-mm nodules. No false-positive nodules but high inter-observer reliability and inter-technique correlation were found. Volume was underestimated manually by 24.1 ± 14.0 % for nodules of any density, and 26.4 ± 15.5 % for solid nodules, compared with 7.6 ± 8.5 % (P < 0.01) semi-automatically. CONCLUSION: In an anthropomorphic phantom study, the sensitivity of detection is 100 % for nodules of >5 mm in diameter. Semi-automated volumetry yielded more accurate nodule volumes than manual measurements. KEY POINTS: • Computed tomography has become the definitive investigation of the chest. • Low-dose CT techniques have recently been introduced. • Low-dose CT is reliable for detecting spherical pulmonary nodules of >5 mm. • Semi-automated volumetry is more accurate than manual measurement for pulmonary nodules. • No difference in the accuracy of volumetry was found between 16- and 64- MDCT.
format Online
Article
Text
id pubmed-3517707
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-35177072012-12-11 Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector CT: an anthropomorphic phantom study Xie, Xueqian Zhao, Yingru Snijder, Roland A. van Ooijen, Peter M. A. de Jong, Pim A. Oudkerk, Matthijs de Bock, Geertruida H. Vliegenthart, Rozemarijn Greuter, Marcel J. W. Eur Radiol Chest OBJECTIVE: To assess the sensitivity of detection and accuracy of volumetry by manual and semi-automated quantification of artificial pulmonary nodules in an anthropomorphic thoracic phantom on low-dose CT. METHODS: Fifteen artificial spherical nodules (diameter 3, 5, 8, 10 and 12 mm; CT densities -800, -630 and +100 HU) were randomly placed inside an anthropomorphic thoracic phantom. The phantom was examined on 16- and 64-row multidetector CT with a low-dose protocol. Two independent blinded observers screened for pulmonary nodules. Nodule diameter was measured manually, and volume calculated. For solid nodules (+100 HU), diameter and volume were also evaluated by semi-automated software. Differences in observed volumes between the manual and semi-automated method were evaluated by a t-test. RESULTS: Sensitivity was 100 % for all nodules of >5 mm and larger, 60–80 % for solid and 0–20 % for non-solid 3-mm nodules. No false-positive nodules but high inter-observer reliability and inter-technique correlation were found. Volume was underestimated manually by 24.1 ± 14.0 % for nodules of any density, and 26.4 ± 15.5 % for solid nodules, compared with 7.6 ± 8.5 % (P < 0.01) semi-automatically. CONCLUSION: In an anthropomorphic phantom study, the sensitivity of detection is 100 % for nodules of >5 mm in diameter. Semi-automated volumetry yielded more accurate nodule volumes than manual measurements. KEY POINTS: • Computed tomography has become the definitive investigation of the chest. • Low-dose CT techniques have recently been introduced. • Low-dose CT is reliable for detecting spherical pulmonary nodules of >5 mm. • Semi-automated volumetry is more accurate than manual measurement for pulmonary nodules. • No difference in the accuracy of volumetry was found between 16- and 64- MDCT. Springer-Verlag 2012-07-14 2013 /pmc/articles/PMC3517707/ /pubmed/22797957 http://dx.doi.org/10.1007/s00330-012-2570-7 Text en © The Author(s) 2012 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Chest
Xie, Xueqian
Zhao, Yingru
Snijder, Roland A.
van Ooijen, Peter M. A.
de Jong, Pim A.
Oudkerk, Matthijs
de Bock, Geertruida H.
Vliegenthart, Rozemarijn
Greuter, Marcel J. W.
Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector CT: an anthropomorphic phantom study
title Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector CT: an anthropomorphic phantom study
title_full Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector CT: an anthropomorphic phantom study
title_fullStr Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector CT: an anthropomorphic phantom study
title_full_unstemmed Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector CT: an anthropomorphic phantom study
title_short Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector CT: an anthropomorphic phantom study
title_sort sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector ct: an anthropomorphic phantom study
topic Chest
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3517707/
https://www.ncbi.nlm.nih.gov/pubmed/22797957
http://dx.doi.org/10.1007/s00330-012-2570-7
work_keys_str_mv AT xiexueqian sensitivityandaccuracyofvolumetryofpulmonarynodulesonlowdose16and64rowmultidetectorctananthropomorphicphantomstudy
AT zhaoyingru sensitivityandaccuracyofvolumetryofpulmonarynodulesonlowdose16and64rowmultidetectorctananthropomorphicphantomstudy
AT snijderrolanda sensitivityandaccuracyofvolumetryofpulmonarynodulesonlowdose16and64rowmultidetectorctananthropomorphicphantomstudy
AT vanooijenpeterma sensitivityandaccuracyofvolumetryofpulmonarynodulesonlowdose16and64rowmultidetectorctananthropomorphicphantomstudy
AT dejongpima sensitivityandaccuracyofvolumetryofpulmonarynodulesonlowdose16and64rowmultidetectorctananthropomorphicphantomstudy
AT oudkerkmatthijs sensitivityandaccuracyofvolumetryofpulmonarynodulesonlowdose16and64rowmultidetectorctananthropomorphicphantomstudy
AT debockgeertruidah sensitivityandaccuracyofvolumetryofpulmonarynodulesonlowdose16and64rowmultidetectorctananthropomorphicphantomstudy
AT vliegenthartrozemarijn sensitivityandaccuracyofvolumetryofpulmonarynodulesonlowdose16and64rowmultidetectorctananthropomorphicphantomstudy
AT greutermarceljw sensitivityandaccuracyofvolumetryofpulmonarynodulesonlowdose16and64rowmultidetectorctananthropomorphicphantomstudy