Cargando…

Wear, bone density, functional outcome and survival in vitamin E-incorporated polyethylene cups in reversed hybrid total hip arthroplasty: design of a randomized controlled trial

BACKGROUND: Aseptic loosening of total hip arthroplasties is generally caused by periprosthetic bone resorption due to tissue reactions on polyethylene wear particles. In vitro testing of polyethylene cups incorporated with vitamin E shows increased wear resistance. The objective of this study is to...

Descripción completa

Detalles Bibliográficos
Autores principales: van der Veen, Hugo C, van den Akker-Scheek, Inge, Bulstra, Sjoerd K, van Raay, Jos JAM
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3517763/
https://www.ncbi.nlm.nih.gov/pubmed/22994935
http://dx.doi.org/10.1186/1471-2474-13-178
_version_ 1782252470161899520
author van der Veen, Hugo C
van den Akker-Scheek, Inge
Bulstra, Sjoerd K
van Raay, Jos JAM
author_facet van der Veen, Hugo C
van den Akker-Scheek, Inge
Bulstra, Sjoerd K
van Raay, Jos JAM
author_sort van der Veen, Hugo C
collection PubMed
description BACKGROUND: Aseptic loosening of total hip arthroplasties is generally caused by periprosthetic bone resorption due to tissue reactions on polyethylene wear particles. In vitro testing of polyethylene cups incorporated with vitamin E shows increased wear resistance. The objective of this study is to compare vitamin E-stabilized highly cross-linked polyethylene with conventional cross-linked polyethylene in “reversed hybrid” total hip arthroplasties (cemented all-polyethylene cups combined with uncemented femoral stems). We hypothesize that the adjunction of vitamin E leads to a decrease in polyethylene wear in the long-term. We also expect changes in bone mineral density, less osteolysis, equal functional scores and increased implant survival in polyethylene cemented cups incorporated with vitamin E in the long-term. DESIGN: A double-blinded randomized controlled trial will be conducted. Patients to be included are aged under 70, suffer from non-inflammatory degenerative joint disease of the hip and are scheduled for a primary total hip arthroplasty. The study group will receive a reversed hybrid total hip arthroplasty with a vitamin E-stabilized highly cross-linked polyethylene cemented cup. The control group will receive a reversed hybrid total hip arthroplasty with a conventional cross-linked polyethylene cemented cup. Radiological follow-up will be assessed at 6 weeks and at 1, 3, 5, 7 and 10 years postoperatively, to determine polyethylene wear and osteolysis. Patient-reported functional status (HOOS), physician-reported functional status (Harris Hip Score) and patients’ physical activity behavior (SQUASH) will also be assessed at these intervals. Acetabular bone mineral density will be assessed by dual energy X-ray absorptiometry (DEXA) at 6 weeks and at 1 year and 2 years postoperatively. Implant survival will be determined at 10 years postoperatively. DISCUSSION: In vitro results of vitamin E-stabilized polyethylene are promising, showing increased wear resistance. However, controlled clinical follow-up data are not available at this moment. This randomized controlled trial has been designed to determine wear, bone mineral density, functional outcome and survival in reversed hybrid total hip arthroplasty comparing cemented vitamin E-stabilized highly cross-linked polyethylene cups with cemented conventional cross-linked polyethylene cups. TRIAL REGISTRATION: Dutch Trial Registry NTR3049
format Online
Article
Text
id pubmed-3517763
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-35177632012-12-09 Wear, bone density, functional outcome and survival in vitamin E-incorporated polyethylene cups in reversed hybrid total hip arthroplasty: design of a randomized controlled trial van der Veen, Hugo C van den Akker-Scheek, Inge Bulstra, Sjoerd K van Raay, Jos JAM BMC Musculoskelet Disord Study Protocol BACKGROUND: Aseptic loosening of total hip arthroplasties is generally caused by periprosthetic bone resorption due to tissue reactions on polyethylene wear particles. In vitro testing of polyethylene cups incorporated with vitamin E shows increased wear resistance. The objective of this study is to compare vitamin E-stabilized highly cross-linked polyethylene with conventional cross-linked polyethylene in “reversed hybrid” total hip arthroplasties (cemented all-polyethylene cups combined with uncemented femoral stems). We hypothesize that the adjunction of vitamin E leads to a decrease in polyethylene wear in the long-term. We also expect changes in bone mineral density, less osteolysis, equal functional scores and increased implant survival in polyethylene cemented cups incorporated with vitamin E in the long-term. DESIGN: A double-blinded randomized controlled trial will be conducted. Patients to be included are aged under 70, suffer from non-inflammatory degenerative joint disease of the hip and are scheduled for a primary total hip arthroplasty. The study group will receive a reversed hybrid total hip arthroplasty with a vitamin E-stabilized highly cross-linked polyethylene cemented cup. The control group will receive a reversed hybrid total hip arthroplasty with a conventional cross-linked polyethylene cemented cup. Radiological follow-up will be assessed at 6 weeks and at 1, 3, 5, 7 and 10 years postoperatively, to determine polyethylene wear and osteolysis. Patient-reported functional status (HOOS), physician-reported functional status (Harris Hip Score) and patients’ physical activity behavior (SQUASH) will also be assessed at these intervals. Acetabular bone mineral density will be assessed by dual energy X-ray absorptiometry (DEXA) at 6 weeks and at 1 year and 2 years postoperatively. Implant survival will be determined at 10 years postoperatively. DISCUSSION: In vitro results of vitamin E-stabilized polyethylene are promising, showing increased wear resistance. However, controlled clinical follow-up data are not available at this moment. This randomized controlled trial has been designed to determine wear, bone mineral density, functional outcome and survival in reversed hybrid total hip arthroplasty comparing cemented vitamin E-stabilized highly cross-linked polyethylene cups with cemented conventional cross-linked polyethylene cups. TRIAL REGISTRATION: Dutch Trial Registry NTR3049 BioMed Central 2012-09-20 /pmc/articles/PMC3517763/ /pubmed/22994935 http://dx.doi.org/10.1186/1471-2474-13-178 Text en Copyright ©2012 van der Veen et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Study Protocol
van der Veen, Hugo C
van den Akker-Scheek, Inge
Bulstra, Sjoerd K
van Raay, Jos JAM
Wear, bone density, functional outcome and survival in vitamin E-incorporated polyethylene cups in reversed hybrid total hip arthroplasty: design of a randomized controlled trial
title Wear, bone density, functional outcome and survival in vitamin E-incorporated polyethylene cups in reversed hybrid total hip arthroplasty: design of a randomized controlled trial
title_full Wear, bone density, functional outcome and survival in vitamin E-incorporated polyethylene cups in reversed hybrid total hip arthroplasty: design of a randomized controlled trial
title_fullStr Wear, bone density, functional outcome and survival in vitamin E-incorporated polyethylene cups in reversed hybrid total hip arthroplasty: design of a randomized controlled trial
title_full_unstemmed Wear, bone density, functional outcome and survival in vitamin E-incorporated polyethylene cups in reversed hybrid total hip arthroplasty: design of a randomized controlled trial
title_short Wear, bone density, functional outcome and survival in vitamin E-incorporated polyethylene cups in reversed hybrid total hip arthroplasty: design of a randomized controlled trial
title_sort wear, bone density, functional outcome and survival in vitamin e-incorporated polyethylene cups in reversed hybrid total hip arthroplasty: design of a randomized controlled trial
topic Study Protocol
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3517763/
https://www.ncbi.nlm.nih.gov/pubmed/22994935
http://dx.doi.org/10.1186/1471-2474-13-178
work_keys_str_mv AT vanderveenhugoc wearbonedensityfunctionaloutcomeandsurvivalinvitamineincorporatedpolyethylenecupsinreversedhybridtotalhiparthroplastydesignofarandomizedcontrolledtrial
AT vandenakkerscheekinge wearbonedensityfunctionaloutcomeandsurvivalinvitamineincorporatedpolyethylenecupsinreversedhybridtotalhiparthroplastydesignofarandomizedcontrolledtrial
AT bulstrasjoerdk wearbonedensityfunctionaloutcomeandsurvivalinvitamineincorporatedpolyethylenecupsinreversedhybridtotalhiparthroplastydesignofarandomizedcontrolledtrial
AT vanraayjosjam wearbonedensityfunctionaloutcomeandsurvivalinvitamineincorporatedpolyethylenecupsinreversedhybridtotalhiparthroplastydesignofarandomizedcontrolledtrial