Cargando…
Loop-Mediated Isothermal Amplification for Detection of Staphylococcus aureus in Dairy Cow Suffering from Mastitis
To develop a rapid detection method of Staphylococcus aureus using loop-mediated isothermal amplification (LAMP), four specific primers were designed according to six distinct sequences of the nuc gene. In addition, the specificity and sensitivity of LAMP were verified and compared with those of PCR...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3519349/ https://www.ncbi.nlm.nih.gov/pubmed/23251078 http://dx.doi.org/10.1155/2012/435982 |
_version_ | 1782252657566547968 |
---|---|
author | Tie, Zhang Chunguang, Wang Xiaoyuan, Wei Xinghua, Zhao Xiuhui, Zhong |
author_facet | Tie, Zhang Chunguang, Wang Xiaoyuan, Wei Xinghua, Zhao Xiuhui, Zhong |
author_sort | Tie, Zhang |
collection | PubMed |
description | To develop a rapid detection method of Staphylococcus aureus using loop-mediated isothermal amplification (LAMP), four specific primers were designed according to six distinct sequences of the nuc gene. In addition, the specificity and sensitivity of LAMP were verified and compared with those of PCR. Results showed that the LAMP reaction was completed within 45 min at 62.5°C, and ladder bands were appeared in LAMP products analyzed by gel electrophoresis. After adding 1x SYBR Green l, the positive reaction tube showed green color and the negative reaction tube remained orange, indicating that the LAMP has high specificity. The minimal detectable concentration of LAMP was 1 × 10(2) CFU/mL and that of PCR was 1 × 10(4) CFU/mL, indicating that the LAMP was 100 times more sensitive than the PCR. The LAMP method for detection of Staphylococcus aureus has many advantages, such as simple operation, high sensitivity, high specificity, and rapid analysis. Therefore, this method is more suitable for the rapid on-site detection of Staphylococcus aureus. |
format | Online Article Text |
id | pubmed-3519349 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-35193492012-12-18 Loop-Mediated Isothermal Amplification for Detection of Staphylococcus aureus in Dairy Cow Suffering from Mastitis Tie, Zhang Chunguang, Wang Xiaoyuan, Wei Xinghua, Zhao Xiuhui, Zhong J Biomed Biotechnol Research Article To develop a rapid detection method of Staphylococcus aureus using loop-mediated isothermal amplification (LAMP), four specific primers were designed according to six distinct sequences of the nuc gene. In addition, the specificity and sensitivity of LAMP were verified and compared with those of PCR. Results showed that the LAMP reaction was completed within 45 min at 62.5°C, and ladder bands were appeared in LAMP products analyzed by gel electrophoresis. After adding 1x SYBR Green l, the positive reaction tube showed green color and the negative reaction tube remained orange, indicating that the LAMP has high specificity. The minimal detectable concentration of LAMP was 1 × 10(2) CFU/mL and that of PCR was 1 × 10(4) CFU/mL, indicating that the LAMP was 100 times more sensitive than the PCR. The LAMP method for detection of Staphylococcus aureus has many advantages, such as simple operation, high sensitivity, high specificity, and rapid analysis. Therefore, this method is more suitable for the rapid on-site detection of Staphylococcus aureus. Hindawi Publishing Corporation 2012 2012-11-19 /pmc/articles/PMC3519349/ /pubmed/23251078 http://dx.doi.org/10.1155/2012/435982 Text en Copyright © 2012 Zhang Tie et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Tie, Zhang Chunguang, Wang Xiaoyuan, Wei Xinghua, Zhao Xiuhui, Zhong Loop-Mediated Isothermal Amplification for Detection of Staphylococcus aureus in Dairy Cow Suffering from Mastitis |
title | Loop-Mediated Isothermal Amplification for Detection of Staphylococcus aureus in Dairy Cow Suffering from Mastitis |
title_full | Loop-Mediated Isothermal Amplification for Detection of Staphylococcus aureus in Dairy Cow Suffering from Mastitis |
title_fullStr | Loop-Mediated Isothermal Amplification for Detection of Staphylococcus aureus in Dairy Cow Suffering from Mastitis |
title_full_unstemmed | Loop-Mediated Isothermal Amplification for Detection of Staphylococcus aureus in Dairy Cow Suffering from Mastitis |
title_short | Loop-Mediated Isothermal Amplification for Detection of Staphylococcus aureus in Dairy Cow Suffering from Mastitis |
title_sort | loop-mediated isothermal amplification for detection of staphylococcus aureus in dairy cow suffering from mastitis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3519349/ https://www.ncbi.nlm.nih.gov/pubmed/23251078 http://dx.doi.org/10.1155/2012/435982 |
work_keys_str_mv | AT tiezhang loopmediatedisothermalamplificationfordetectionofstaphylococcusaureusindairycowsufferingfrommastitis AT chunguangwang loopmediatedisothermalamplificationfordetectionofstaphylococcusaureusindairycowsufferingfrommastitis AT xiaoyuanwei loopmediatedisothermalamplificationfordetectionofstaphylococcusaureusindairycowsufferingfrommastitis AT xinghuazhao loopmediatedisothermalamplificationfordetectionofstaphylococcusaureusindairycowsufferingfrommastitis AT xiuhuizhong loopmediatedisothermalamplificationfordetectionofstaphylococcusaureusindairycowsufferingfrommastitis |