Cargando…

Simultaneous amplitude-contrast and phase-contrast surface plasmon resonance imaging by use of digital holography

The surface plasmon resonance imaging technique provides a tool that allows high-throughput analysis and real-time kinetic measurement. A simultaneous amplitude-contrast and phase-contrast surface plasmon resonance imaging method is presented. The amplitude-contrast and phase-contrast images are sim...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Shiping, Zhong, Jingang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Optical Society of America 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3521296/
https://www.ncbi.nlm.nih.gov/pubmed/23243569
http://dx.doi.org/10.1364/BOE.3.003190
_version_ 1782252925012148224
author Li, Shiping
Zhong, Jingang
author_facet Li, Shiping
Zhong, Jingang
author_sort Li, Shiping
collection PubMed
description The surface plasmon resonance imaging technique provides a tool that allows high-throughput analysis and real-time kinetic measurement. A simultaneous amplitude-contrast and phase-contrast surface plasmon resonance imaging method is presented. The amplitude-contrast and phase-contrast images are simultaneously obtained by use of digital holography. The detection sensitivity of amplitude-contrast imaging and phase-contrast imaging can compensate for each other. Thus, the detectable sample components may cover a wider range of refractive index values for the simultaneous amplitude-contrast and phase-contrast imaging method than for the phase-contrast imaging method or amplitude-contrast imaging method. A detailed description of the theory and an experiment of monitoring the evaporation process of a drop of NaCl injection in real time are presented. In addition, the amplitude-contrast image has less coherent noise by digital holography.
format Online
Article
Text
id pubmed-3521296
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Optical Society of America
record_format MEDLINE/PubMed
spelling pubmed-35212962012-12-14 Simultaneous amplitude-contrast and phase-contrast surface plasmon resonance imaging by use of digital holography Li, Shiping Zhong, Jingang Biomed Opt Express Biosensors and Molecular Diagnostics The surface plasmon resonance imaging technique provides a tool that allows high-throughput analysis and real-time kinetic measurement. A simultaneous amplitude-contrast and phase-contrast surface plasmon resonance imaging method is presented. The amplitude-contrast and phase-contrast images are simultaneously obtained by use of digital holography. The detection sensitivity of amplitude-contrast imaging and phase-contrast imaging can compensate for each other. Thus, the detectable sample components may cover a wider range of refractive index values for the simultaneous amplitude-contrast and phase-contrast imaging method than for the phase-contrast imaging method or amplitude-contrast imaging method. A detailed description of the theory and an experiment of monitoring the evaporation process of a drop of NaCl injection in real time are presented. In addition, the amplitude-contrast image has less coherent noise by digital holography. Optical Society of America 2012-11-08 /pmc/articles/PMC3521296/ /pubmed/23243569 http://dx.doi.org/10.1364/BOE.3.003190 Text en ©2012 Optical Society of America http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License, which permits download and redistribution, provided that the original work is properly cited. This license restricts the article from being modified or used commercially.
spellingShingle Biosensors and Molecular Diagnostics
Li, Shiping
Zhong, Jingang
Simultaneous amplitude-contrast and phase-contrast surface plasmon resonance imaging by use of digital holography
title Simultaneous amplitude-contrast and phase-contrast surface plasmon resonance imaging by use of digital holography
title_full Simultaneous amplitude-contrast and phase-contrast surface plasmon resonance imaging by use of digital holography
title_fullStr Simultaneous amplitude-contrast and phase-contrast surface plasmon resonance imaging by use of digital holography
title_full_unstemmed Simultaneous amplitude-contrast and phase-contrast surface plasmon resonance imaging by use of digital holography
title_short Simultaneous amplitude-contrast and phase-contrast surface plasmon resonance imaging by use of digital holography
title_sort simultaneous amplitude-contrast and phase-contrast surface plasmon resonance imaging by use of digital holography
topic Biosensors and Molecular Diagnostics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3521296/
https://www.ncbi.nlm.nih.gov/pubmed/23243569
http://dx.doi.org/10.1364/BOE.3.003190
work_keys_str_mv AT lishiping simultaneousamplitudecontrastandphasecontrastsurfaceplasmonresonanceimagingbyuseofdigitalholography
AT zhongjingang simultaneousamplitudecontrastandphasecontrastsurfaceplasmonresonanceimagingbyuseofdigitalholography