Cargando…

High Spatial Resolution and Temporally Resolved T(2) (*) Mapping of Normal Human Myocardium at 7.0 Tesla: An Ultrahigh Field Magnetic Resonance Feasibility Study

Myocardial tissue characterization using T(2) (*) relaxation mapping techniques is an emerging application of (pre)clinical cardiovascular magnetic resonance imaging. The increase in microscopic susceptibility at higher magnetic field strengths renders myocardial T(2) (*) mapping at ultrahigh magnet...

Descripción completa

Detalles Bibliográficos
Autores principales: Hezel, Fabian, Thalhammer, Christof, Waiczies, Sonia, Schulz-Menger, Jeanette, Niendorf, Thoralf
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3522647/
https://www.ncbi.nlm.nih.gov/pubmed/23251708
http://dx.doi.org/10.1371/journal.pone.0052324
_version_ 1782253106562596864
author Hezel, Fabian
Thalhammer, Christof
Waiczies, Sonia
Schulz-Menger, Jeanette
Niendorf, Thoralf
author_facet Hezel, Fabian
Thalhammer, Christof
Waiczies, Sonia
Schulz-Menger, Jeanette
Niendorf, Thoralf
author_sort Hezel, Fabian
collection PubMed
description Myocardial tissue characterization using T(2) (*) relaxation mapping techniques is an emerging application of (pre)clinical cardiovascular magnetic resonance imaging. The increase in microscopic susceptibility at higher magnetic field strengths renders myocardial T(2) (*) mapping at ultrahigh magnetic fields conceptually appealing. This work demonstrates the feasibility of myocardial T(2) (*) imaging at 7.0 T and examines the applicability of temporally-resolved and high spatial resolution myocardial T(2) (*) mapping. In phantom experiments single cardiac phase and dynamic (CINE) gradient echo imaging techniques provided similar T(2) (*) maps. In vivo studies showed that the peak-to-peak B(0) difference following volume selective shimming was reduced to approximately 80 Hz for the four chamber view and mid-ventricular short axis view of the heart and to 65 Hz for the left ventricle. No severe susceptibility artifacts were detected in the septum and in the lateral wall for T(2) (*) weighting ranging from TE = 2.04 ms to TE = 10.2 ms. For TE >7 ms, a susceptibility weighting induced signal void was observed within the anterior and inferior myocardial segments. The longest T(2) (*) values were found for anterior (T(2) (*) = 14.0 ms), anteroseptal (T(2) (*) = 17.2 ms) and inferoseptal (T(2) (*) = 16.5 ms) myocardial segments. Shorter T(2) (*) values were observed for inferior (T(2) (*) = 10.6 ms) and inferolateral (T(2) (*) = 11.4 ms) segments. A significant difference (p = 0.002) in T(2) (*) values was observed between end-diastole and end-systole with T(2) (*) changes of up to approximately 27% over the cardiac cycle which were pronounced in the septum. To conclude, these results underscore the challenges of myocardial T(2) (*) mapping at 7.0 T but demonstrate that these issues can be offset by using tailored shimming techniques and dedicated acquisition schemes.
format Online
Article
Text
id pubmed-3522647
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-35226472012-12-18 High Spatial Resolution and Temporally Resolved T(2) (*) Mapping of Normal Human Myocardium at 7.0 Tesla: An Ultrahigh Field Magnetic Resonance Feasibility Study Hezel, Fabian Thalhammer, Christof Waiczies, Sonia Schulz-Menger, Jeanette Niendorf, Thoralf PLoS One Research Article Myocardial tissue characterization using T(2) (*) relaxation mapping techniques is an emerging application of (pre)clinical cardiovascular magnetic resonance imaging. The increase in microscopic susceptibility at higher magnetic field strengths renders myocardial T(2) (*) mapping at ultrahigh magnetic fields conceptually appealing. This work demonstrates the feasibility of myocardial T(2) (*) imaging at 7.0 T and examines the applicability of temporally-resolved and high spatial resolution myocardial T(2) (*) mapping. In phantom experiments single cardiac phase and dynamic (CINE) gradient echo imaging techniques provided similar T(2) (*) maps. In vivo studies showed that the peak-to-peak B(0) difference following volume selective shimming was reduced to approximately 80 Hz for the four chamber view and mid-ventricular short axis view of the heart and to 65 Hz for the left ventricle. No severe susceptibility artifacts were detected in the septum and in the lateral wall for T(2) (*) weighting ranging from TE = 2.04 ms to TE = 10.2 ms. For TE >7 ms, a susceptibility weighting induced signal void was observed within the anterior and inferior myocardial segments. The longest T(2) (*) values were found for anterior (T(2) (*) = 14.0 ms), anteroseptal (T(2) (*) = 17.2 ms) and inferoseptal (T(2) (*) = 16.5 ms) myocardial segments. Shorter T(2) (*) values were observed for inferior (T(2) (*) = 10.6 ms) and inferolateral (T(2) (*) = 11.4 ms) segments. A significant difference (p = 0.002) in T(2) (*) values was observed between end-diastole and end-systole with T(2) (*) changes of up to approximately 27% over the cardiac cycle which were pronounced in the septum. To conclude, these results underscore the challenges of myocardial T(2) (*) mapping at 7.0 T but demonstrate that these issues can be offset by using tailored shimming techniques and dedicated acquisition schemes. Public Library of Science 2012-12-14 /pmc/articles/PMC3522647/ /pubmed/23251708 http://dx.doi.org/10.1371/journal.pone.0052324 Text en © 2012 Hezel et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Hezel, Fabian
Thalhammer, Christof
Waiczies, Sonia
Schulz-Menger, Jeanette
Niendorf, Thoralf
High Spatial Resolution and Temporally Resolved T(2) (*) Mapping of Normal Human Myocardium at 7.0 Tesla: An Ultrahigh Field Magnetic Resonance Feasibility Study
title High Spatial Resolution and Temporally Resolved T(2) (*) Mapping of Normal Human Myocardium at 7.0 Tesla: An Ultrahigh Field Magnetic Resonance Feasibility Study
title_full High Spatial Resolution and Temporally Resolved T(2) (*) Mapping of Normal Human Myocardium at 7.0 Tesla: An Ultrahigh Field Magnetic Resonance Feasibility Study
title_fullStr High Spatial Resolution and Temporally Resolved T(2) (*) Mapping of Normal Human Myocardium at 7.0 Tesla: An Ultrahigh Field Magnetic Resonance Feasibility Study
title_full_unstemmed High Spatial Resolution and Temporally Resolved T(2) (*) Mapping of Normal Human Myocardium at 7.0 Tesla: An Ultrahigh Field Magnetic Resonance Feasibility Study
title_short High Spatial Resolution and Temporally Resolved T(2) (*) Mapping of Normal Human Myocardium at 7.0 Tesla: An Ultrahigh Field Magnetic Resonance Feasibility Study
title_sort high spatial resolution and temporally resolved t(2) (*) mapping of normal human myocardium at 7.0 tesla: an ultrahigh field magnetic resonance feasibility study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3522647/
https://www.ncbi.nlm.nih.gov/pubmed/23251708
http://dx.doi.org/10.1371/journal.pone.0052324
work_keys_str_mv AT hezelfabian highspatialresolutionandtemporallyresolvedt2mappingofnormalhumanmyocardiumat70teslaanultrahighfieldmagneticresonancefeasibilitystudy
AT thalhammerchristof highspatialresolutionandtemporallyresolvedt2mappingofnormalhumanmyocardiumat70teslaanultrahighfieldmagneticresonancefeasibilitystudy
AT waicziessonia highspatialresolutionandtemporallyresolvedt2mappingofnormalhumanmyocardiumat70teslaanultrahighfieldmagneticresonancefeasibilitystudy
AT schulzmengerjeanette highspatialresolutionandtemporallyresolvedt2mappingofnormalhumanmyocardiumat70teslaanultrahighfieldmagneticresonancefeasibilitystudy
AT niendorfthoralf highspatialresolutionandtemporallyresolvedt2mappingofnormalhumanmyocardiumat70teslaanultrahighfieldmagneticresonancefeasibilitystudy