Cargando…

Hemodynamic efficacy of sequential hemoclip application using the Olympus HX-110/610 reloadable clipping device in spurting bleedings

BACKGROUND: Hemoclip application in GI-hemorrhage has proven to be effective. Clinical experience shows that multiple clips are frequently necessary. In 2005, an easily reloadable clip-applicator was introduced. We evaluated the hemodynamic efficacy of this new device. MATERIAL/METHODS: We prospecti...

Descripción completa

Detalles Bibliográficos
Autores principales: Ende, Anke, Zopf, Yurdaguel, Heide, Roland, Bernatik, Thomas, Wehler, Markus, Schwab, Dieter, Hahn, Eckhart G., Maiss, Juergen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3524692/
https://www.ncbi.nlm.nih.gov/pubmed/21169916
http://dx.doi.org/10.12659/MSM.881313
_version_ 1782253350920650752
author Ende, Anke
Zopf, Yurdaguel
Heide, Roland
Bernatik, Thomas
Wehler, Markus
Schwab, Dieter
Hahn, Eckhart G.
Maiss, Juergen
author_facet Ende, Anke
Zopf, Yurdaguel
Heide, Roland
Bernatik, Thomas
Wehler, Markus
Schwab, Dieter
Hahn, Eckhart G.
Maiss, Juergen
author_sort Ende, Anke
collection PubMed
description BACKGROUND: Hemoclip application in GI-hemorrhage has proven to be effective. Clinical experience shows that multiple clips are frequently necessary. In 2005, an easily reloadable clip-applicator was introduced. We evaluated the hemodynamic efficacy of this new device. MATERIAL/METHODS: We prospectively compared the new clipping device (Olympus HX 110/610) in a validated experimental setting using the compactEASIE(®)-simulator for GI bleeding. The artificial blood circulation system in the simulator was connected to a pressure transducer. Four investigators of different endoscopic experience (1000–6000 endoscopies) treated 12 bleeding sources each, with up to 6 clips for each bleeding location. Pressures were recorded to objectify the additive effects of sequential clip application on the reduction in vessel diameter. The intervention was abandoned if a maximum measurable pressure of 300 mmHg was achieved. RESULTS: Hemoclip application led to a significant increase of peak pressure (91±100 mmHg, p<0.001) and mean pressure (95±99 mmHg, p<0.001), representing a significant reduction in vessel diameter. Pooled data showed a significant stepwise increase in mean and maximum system pressure, resulting in reduction of vessel diameter up to the fifth hemoclip. On average, 5 clips (range 1–6) were used. More experienced endoscopists achieved a higher increase in mean pressure (167 and 118 mmHg vs 72 and 23 mmHg, p<0.05). Mean reloading time was 39 seconds (19–49 sec). CONCLUSIONS: Sequential application of multiple hemoclips led to an increasing effect, comparable to the results of previous clinical trials. The number of hemoclips applied correlated inversely, but not significantly, with the endoscopist’s experience. Expensive single-use clips appear dispensable in view of the short reloading time.
format Online
Article
Text
id pubmed-3524692
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-35246922013-04-24 Hemodynamic efficacy of sequential hemoclip application using the Olympus HX-110/610 reloadable clipping device in spurting bleedings Ende, Anke Zopf, Yurdaguel Heide, Roland Bernatik, Thomas Wehler, Markus Schwab, Dieter Hahn, Eckhart G. Maiss, Juergen Med Sci Monit Diagnostics and Medical Technology BACKGROUND: Hemoclip application in GI-hemorrhage has proven to be effective. Clinical experience shows that multiple clips are frequently necessary. In 2005, an easily reloadable clip-applicator was introduced. We evaluated the hemodynamic efficacy of this new device. MATERIAL/METHODS: We prospectively compared the new clipping device (Olympus HX 110/610) in a validated experimental setting using the compactEASIE(®)-simulator for GI bleeding. The artificial blood circulation system in the simulator was connected to a pressure transducer. Four investigators of different endoscopic experience (1000–6000 endoscopies) treated 12 bleeding sources each, with up to 6 clips for each bleeding location. Pressures were recorded to objectify the additive effects of sequential clip application on the reduction in vessel diameter. The intervention was abandoned if a maximum measurable pressure of 300 mmHg was achieved. RESULTS: Hemoclip application led to a significant increase of peak pressure (91±100 mmHg, p<0.001) and mean pressure (95±99 mmHg, p<0.001), representing a significant reduction in vessel diameter. Pooled data showed a significant stepwise increase in mean and maximum system pressure, resulting in reduction of vessel diameter up to the fifth hemoclip. On average, 5 clips (range 1–6) were used. More experienced endoscopists achieved a higher increase in mean pressure (167 and 118 mmHg vs 72 and 23 mmHg, p<0.05). Mean reloading time was 39 seconds (19–49 sec). CONCLUSIONS: Sequential application of multiple hemoclips led to an increasing effect, comparable to the results of previous clinical trials. The number of hemoclips applied correlated inversely, but not significantly, with the endoscopist’s experience. Expensive single-use clips appear dispensable in view of the short reloading time. International Scientific Literature, Inc. 2011-01-01 /pmc/articles/PMC3524692/ /pubmed/21169916 http://dx.doi.org/10.12659/MSM.881313 Text en © Med Sci Monit, 2011 This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License.
spellingShingle Diagnostics and Medical Technology
Ende, Anke
Zopf, Yurdaguel
Heide, Roland
Bernatik, Thomas
Wehler, Markus
Schwab, Dieter
Hahn, Eckhart G.
Maiss, Juergen
Hemodynamic efficacy of sequential hemoclip application using the Olympus HX-110/610 reloadable clipping device in spurting bleedings
title Hemodynamic efficacy of sequential hemoclip application using the Olympus HX-110/610 reloadable clipping device in spurting bleedings
title_full Hemodynamic efficacy of sequential hemoclip application using the Olympus HX-110/610 reloadable clipping device in spurting bleedings
title_fullStr Hemodynamic efficacy of sequential hemoclip application using the Olympus HX-110/610 reloadable clipping device in spurting bleedings
title_full_unstemmed Hemodynamic efficacy of sequential hemoclip application using the Olympus HX-110/610 reloadable clipping device in spurting bleedings
title_short Hemodynamic efficacy of sequential hemoclip application using the Olympus HX-110/610 reloadable clipping device in spurting bleedings
title_sort hemodynamic efficacy of sequential hemoclip application using the olympus hx-110/610 reloadable clipping device in spurting bleedings
topic Diagnostics and Medical Technology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3524692/
https://www.ncbi.nlm.nih.gov/pubmed/21169916
http://dx.doi.org/10.12659/MSM.881313
work_keys_str_mv AT endeanke hemodynamicefficacyofsequentialhemoclipapplicationusingtheolympushx110610reloadableclippingdeviceinspurtingbleedings
AT zopfyurdaguel hemodynamicefficacyofsequentialhemoclipapplicationusingtheolympushx110610reloadableclippingdeviceinspurtingbleedings
AT heideroland hemodynamicefficacyofsequentialhemoclipapplicationusingtheolympushx110610reloadableclippingdeviceinspurtingbleedings
AT bernatikthomas hemodynamicefficacyofsequentialhemoclipapplicationusingtheolympushx110610reloadableclippingdeviceinspurtingbleedings
AT wehlermarkus hemodynamicefficacyofsequentialhemoclipapplicationusingtheolympushx110610reloadableclippingdeviceinspurtingbleedings
AT schwabdieter hemodynamicefficacyofsequentialhemoclipapplicationusingtheolympushx110610reloadableclippingdeviceinspurtingbleedings
AT hahneckhartg hemodynamicefficacyofsequentialhemoclipapplicationusingtheolympushx110610reloadableclippingdeviceinspurtingbleedings
AT maissjuergen hemodynamicefficacyofsequentialhemoclipapplicationusingtheolympushx110610reloadableclippingdeviceinspurtingbleedings