Evaluation of the accuracy of manual and automatic scoring of a single airflow channel in patients with a high probability of obstructive sleep apnea

BACKGROUND: ApneaLink™ (AL) is a single-channel type-4 device that measures airflow. A limited number of studies have assessed AL’s usefulness in diagnosing obstructive sleep apnea (OSA) using automated scoring alone. This study was conducted to assess the sensitivity and specificity of AL in a sele...

Descripción completa

Detalles Bibliográficos
Autores principales: BaHammam, Ahmed, Sharif, Munir, Gacuan, Divinagracia E., George, Smitha
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3524694/
https://www.ncbi.nlm.nih.gov/pubmed/21278698
http://dx.doi.org/10.12659/MSM.881379
Descripción
Sumario:BACKGROUND: ApneaLink™ (AL) is a single-channel type-4 device that measures airflow. A limited number of studies have assessed AL’s usefulness in diagnosing obstructive sleep apnea (OSA) using automated scoring alone. This study was conducted to assess the sensitivity and specificity of AL in a selected group of people with clinical suspicion of OSA, using both automatic and manual scoring and comparing the results with those obtained for polysomnography (PSG). MATERIAL/METHODS: Simultaneous overnight recordings of in-laboratory PSG and AL were performed for 95 patients (mean age 46.3±12.6 yr) with a high clinical suspicion of OSA. PSG was scored manually according to the American Academy of Sleep Medicine (AASM) guidelines. AL data were analyzed automatically using a manufacturer-provided computerized algorithm. Manual scoring of the AL flow signal followed the AASM guidelines for reduction in flow. RESULTS: The mean apnea hypopneas index (AHI) for PSG was 34.1±32.4/hr. The AL Auto-AHI was 20.1±25.2/h, and the AL Manual-AHI was 39.5±30.4/h. The Pearson correlation coefficients were r=0.883 between PSG-AHI and AL Auto-AHI, and r=0.966 between PSG-AHI and AL Manual-AHI. At AHIs of 5, 10, 15, and 30, the AL Auto sensitivity/specificity was 0.79/0.68, 0.70/0.89, 0.64/0.94 and 0.63/0.98, and the AL Manual sensitivity/specificity was 1.00/0.43, 1.00/0.56, 0.98/0.58 and 1.00/0.80. CONCLUSIONS: Combining auto and manual scoring of data (automatic scoring followed by manual scoring) recorded by single-channel ApneaLink™ provides good diagnostic agreement with conventional PSG recordings.