Cargando…
Comparison of hemodynamic and metabolic stress responses caused by endotracheal tube and Proseal laryngeal mask airway in laparoscopic cholecystectomy
BACKGROUND: We aimed to compare hemodynamic and endocrine alterations caused by stress response due to Proseal laryngeal mask airway and endotracheal tube usage in laparoscopic cholecystectomy. MATERIALS AND METHODS: Sixty-three ASA I-II patients scheduled for elective laparoscopic cholecystectomy w...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3525032/ https://www.ncbi.nlm.nih.gov/pubmed/23264788 |
_version_ | 1782253382758563840 |
---|---|
author | Güleç, Handan Çakan, Türkay Yaman, Halil Kilinç, Aytül Şadan Başar, Hülya |
author_facet | Güleç, Handan Çakan, Türkay Yaman, Halil Kilinç, Aytül Şadan Başar, Hülya |
author_sort | Güleç, Handan |
collection | PubMed |
description | BACKGROUND: We aimed to compare hemodynamic and endocrine alterations caused by stress response due to Proseal laryngeal mask airway and endotracheal tube usage in laparoscopic cholecystectomy. MATERIALS AND METHODS: Sixty-three ASA I-II patients scheduled for elective laparoscopic cholecystectomy were included in the study. Patients were randomly allocated into two groups of endotracheal tube and Proseal laryngeal mask airway. Standard general anaesthesia was performed in both groups with the same drugs in induction and maintenance of anaesthesia. After anaesthesia induction and 20 minutes after CO(2) insufflations, venous blood samples were obtained for measuring adrenalin, noradrenalin, dopamine and cortisol levels. Hemodynamic and respiratory parameters were recorded at the 1(st), 5(th), 15(th), 30(th) and 45(th) minutes after the insertion of airway devices. RESULTS: No statistically significant differences in age, body mass index, gender, ASA physical status, and operation time were found between the groups (p > 0.05). Changes in hemodynamic and respiratory parameters were not statistically significant when compared between and within groups (p > 0.05). Although no statistically significant differences were observed between and within groups when adrenalin, noradrenalin and dopamine values were compared, serum cortisol levels after CO(2) insufflation in PLMA group were significantly lower than the ETT group (p = 0.024). When serum cortisol levels were compared within groups, cortisol levels 20 minutes after CO(2) insufflation were significantly higher (46.1 (9.5-175.7) and 27.0 (8.3-119.4) in the ETT and PLMA groups, respectively) than cortisol levels after anaesthesia induction (11.3 (2.8-92.5) and 16.6 (4.4-45.4) in the ETT and PLMA groups, respectively) in both groups (p = 0.001). CONCLUSION: PLMA usage is a suitable, effective and safe alternative to ETT in laparoscopic cholecystectomy patients with lower metabolic stress. |
format | Online Article Text |
id | pubmed-3525032 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-35250322012-12-21 Comparison of hemodynamic and metabolic stress responses caused by endotracheal tube and Proseal laryngeal mask airway in laparoscopic cholecystectomy Güleç, Handan Çakan, Türkay Yaman, Halil Kilinç, Aytül Şadan Başar, Hülya J Res Med Sci Original Article BACKGROUND: We aimed to compare hemodynamic and endocrine alterations caused by stress response due to Proseal laryngeal mask airway and endotracheal tube usage in laparoscopic cholecystectomy. MATERIALS AND METHODS: Sixty-three ASA I-II patients scheduled for elective laparoscopic cholecystectomy were included in the study. Patients were randomly allocated into two groups of endotracheal tube and Proseal laryngeal mask airway. Standard general anaesthesia was performed in both groups with the same drugs in induction and maintenance of anaesthesia. After anaesthesia induction and 20 minutes after CO(2) insufflations, venous blood samples were obtained for measuring adrenalin, noradrenalin, dopamine and cortisol levels. Hemodynamic and respiratory parameters were recorded at the 1(st), 5(th), 15(th), 30(th) and 45(th) minutes after the insertion of airway devices. RESULTS: No statistically significant differences in age, body mass index, gender, ASA physical status, and operation time were found between the groups (p > 0.05). Changes in hemodynamic and respiratory parameters were not statistically significant when compared between and within groups (p > 0.05). Although no statistically significant differences were observed between and within groups when adrenalin, noradrenalin and dopamine values were compared, serum cortisol levels after CO(2) insufflation in PLMA group were significantly lower than the ETT group (p = 0.024). When serum cortisol levels were compared within groups, cortisol levels 20 minutes after CO(2) insufflation were significantly higher (46.1 (9.5-175.7) and 27.0 (8.3-119.4) in the ETT and PLMA groups, respectively) than cortisol levels after anaesthesia induction (11.3 (2.8-92.5) and 16.6 (4.4-45.4) in the ETT and PLMA groups, respectively) in both groups (p = 0.001). CONCLUSION: PLMA usage is a suitable, effective and safe alternative to ETT in laparoscopic cholecystectomy patients with lower metabolic stress. Medknow Publications & Media Pvt Ltd 2012-02 /pmc/articles/PMC3525032/ /pubmed/23264788 Text en Copyright: © Journal of Research in Medical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Güleç, Handan Çakan, Türkay Yaman, Halil Kilinç, Aytül Şadan Başar, Hülya Comparison of hemodynamic and metabolic stress responses caused by endotracheal tube and Proseal laryngeal mask airway in laparoscopic cholecystectomy |
title | Comparison of hemodynamic and metabolic stress responses caused by endotracheal tube and Proseal laryngeal mask airway in laparoscopic cholecystectomy |
title_full | Comparison of hemodynamic and metabolic stress responses caused by endotracheal tube and Proseal laryngeal mask airway in laparoscopic cholecystectomy |
title_fullStr | Comparison of hemodynamic and metabolic stress responses caused by endotracheal tube and Proseal laryngeal mask airway in laparoscopic cholecystectomy |
title_full_unstemmed | Comparison of hemodynamic and metabolic stress responses caused by endotracheal tube and Proseal laryngeal mask airway in laparoscopic cholecystectomy |
title_short | Comparison of hemodynamic and metabolic stress responses caused by endotracheal tube and Proseal laryngeal mask airway in laparoscopic cholecystectomy |
title_sort | comparison of hemodynamic and metabolic stress responses caused by endotracheal tube and proseal laryngeal mask airway in laparoscopic cholecystectomy |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3525032/ https://www.ncbi.nlm.nih.gov/pubmed/23264788 |
work_keys_str_mv | AT gulechandan comparisonofhemodynamicandmetabolicstressresponsescausedbyendotrachealtubeandproseallaryngealmaskairwayinlaparoscopiccholecystectomy AT cakanturkay comparisonofhemodynamicandmetabolicstressresponsescausedbyendotrachealtubeandproseallaryngealmaskairwayinlaparoscopiccholecystectomy AT yamanhalil comparisonofhemodynamicandmetabolicstressresponsescausedbyendotrachealtubeandproseallaryngealmaskairwayinlaparoscopiccholecystectomy AT kilincaytulsadan comparisonofhemodynamicandmetabolicstressresponsescausedbyendotrachealtubeandproseallaryngealmaskairwayinlaparoscopiccholecystectomy AT basarhulya comparisonofhemodynamicandmetabolicstressresponsescausedbyendotrachealtubeandproseallaryngealmaskairwayinlaparoscopiccholecystectomy |