Intraocular pressure in a cohort of healthy eastern European schoolchildren: variations in method and corneal thickness

BACKGROUND: Intraocular pressure (IOP) in the developing eye of a child is not always easy to measure and there is no technique that is known to be the most accurate for the young eye. Measurements are needed on many cohorts of children with different tonometers to determine how the values correlate...

Descripción completa

Detalles Bibliográficos
Autores principales: Krzyżanowska-Berkowska, Patrycja, Asejczyk-Widlicka, Magdalena, Pierscionek, Barbara
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3526441/
https://www.ncbi.nlm.nih.gov/pubmed/23199262
http://dx.doi.org/10.1186/1471-2415-12-61
_version_ 1782253561106661376
author Krzyżanowska-Berkowska, Patrycja
Asejczyk-Widlicka, Magdalena
Pierscionek, Barbara
author_facet Krzyżanowska-Berkowska, Patrycja
Asejczyk-Widlicka, Magdalena
Pierscionek, Barbara
author_sort Krzyżanowska-Berkowska, Patrycja
collection PubMed
description BACKGROUND: Intraocular pressure (IOP) in the developing eye of a child is not always easy to measure and there is no technique that is known to be the most accurate for the young eye. Measurements are needed on many cohorts of children with different tonometers to determine how the values correlate between instruments, whether corneal parameters affect readings and whether correlations between age and IOP values can be discerned. The aim of this study was to undertake a comparative analysis of three different tonometers on a group of healthy children to see whether differences exist and whether these may be related to central corneal thickness and/or radius of curvature. In addition, the study adds to the relatively small body of literature on IOP in the growing eye which will collectively allow trends to be identified and ultimately norms to be established. METHODS: IOP was measured on 115 eyes in a group of Polish children, aged between 5–17 years (mean ± standard deviation [SD] 11.3 ± 3.0 years) using three different tonometers: non-contact (NCT), the ICare and Goldmann applanation (GAT). Readings obtained were compared between instruments and with central corneal thickness and radius of curvature. RESULTS: The ICare tonometer provided statistically higher IOP values (16.9 ± 3.4 mmHg) than the GAT (14.7 ± 2.9 mmHg) regardless of corneal thickness and whether or not a correction factor was applied. A correlation was found between central corneal thickness (CCT) and IOP values obtained with all three tonometers but only the IOP values detected with the ICare tonometer showed a statistically significant correlation with radius of curvature (p < 0.004). No correlations with age or gender were found for IOP values measured with any of the instruments. CONCLUSIONS: IOP measurements on children vary significantly between instruments and correlations are affected by the corneal thickness. Further studies on children are needed to determine which instrument is most appropriate and to derive a normative IOP scale for the growing eye.
format Online
Article
Text
id pubmed-3526441
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-35264412012-12-20 Intraocular pressure in a cohort of healthy eastern European schoolchildren: variations in method and corneal thickness Krzyżanowska-Berkowska, Patrycja Asejczyk-Widlicka, Magdalena Pierscionek, Barbara BMC Ophthalmol Research Article BACKGROUND: Intraocular pressure (IOP) in the developing eye of a child is not always easy to measure and there is no technique that is known to be the most accurate for the young eye. Measurements are needed on many cohorts of children with different tonometers to determine how the values correlate between instruments, whether corneal parameters affect readings and whether correlations between age and IOP values can be discerned. The aim of this study was to undertake a comparative analysis of three different tonometers on a group of healthy children to see whether differences exist and whether these may be related to central corneal thickness and/or radius of curvature. In addition, the study adds to the relatively small body of literature on IOP in the growing eye which will collectively allow trends to be identified and ultimately norms to be established. METHODS: IOP was measured on 115 eyes in a group of Polish children, aged between 5–17 years (mean ± standard deviation [SD] 11.3 ± 3.0 years) using three different tonometers: non-contact (NCT), the ICare and Goldmann applanation (GAT). Readings obtained were compared between instruments and with central corneal thickness and radius of curvature. RESULTS: The ICare tonometer provided statistically higher IOP values (16.9 ± 3.4 mmHg) than the GAT (14.7 ± 2.9 mmHg) regardless of corneal thickness and whether or not a correction factor was applied. A correlation was found between central corneal thickness (CCT) and IOP values obtained with all three tonometers but only the IOP values detected with the ICare tonometer showed a statistically significant correlation with radius of curvature (p < 0.004). No correlations with age or gender were found for IOP values measured with any of the instruments. CONCLUSIONS: IOP measurements on children vary significantly between instruments and correlations are affected by the corneal thickness. Further studies on children are needed to determine which instrument is most appropriate and to derive a normative IOP scale for the growing eye. BioMed Central 2012-12-02 /pmc/articles/PMC3526441/ /pubmed/23199262 http://dx.doi.org/10.1186/1471-2415-12-61 Text en Copyright ©2012 Krzyżanowska-Berkowska et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Krzyżanowska-Berkowska, Patrycja
Asejczyk-Widlicka, Magdalena
Pierscionek, Barbara
Intraocular pressure in a cohort of healthy eastern European schoolchildren: variations in method and corneal thickness
title Intraocular pressure in a cohort of healthy eastern European schoolchildren: variations in method and corneal thickness
title_full Intraocular pressure in a cohort of healthy eastern European schoolchildren: variations in method and corneal thickness
title_fullStr Intraocular pressure in a cohort of healthy eastern European schoolchildren: variations in method and corneal thickness
title_full_unstemmed Intraocular pressure in a cohort of healthy eastern European schoolchildren: variations in method and corneal thickness
title_short Intraocular pressure in a cohort of healthy eastern European schoolchildren: variations in method and corneal thickness
title_sort intraocular pressure in a cohort of healthy eastern european schoolchildren: variations in method and corneal thickness
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3526441/
https://www.ncbi.nlm.nih.gov/pubmed/23199262
http://dx.doi.org/10.1186/1471-2415-12-61
work_keys_str_mv AT krzyzanowskaberkowskapatrycja intraocularpressureinacohortofhealthyeasterneuropeanschoolchildrenvariationsinmethodandcornealthickness
AT asejczykwidlickamagdalena intraocularpressureinacohortofhealthyeasterneuropeanschoolchildrenvariationsinmethodandcornealthickness
AT pierscionekbarbara intraocularpressureinacohortofhealthyeasterneuropeanschoolchildrenvariationsinmethodandcornealthickness