Cargando…

Efficient stem cell isolation from under vacuum preserved tissue samples

Different approaches for the isolation of stem/progenitor cells have been reported, including stem cell selection in stringent culture conditions. We evaluated the possibility of isolating human progenitor cells from surgical specimens preserved by under vacuum sealing and cooling, a clinical practi...

Descripción completa

Detalles Bibliográficos
Autores principales: Moggio, Aldo, D'Armento, Giuseppe, Bussolati, Benedetta
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Landes Bioscience 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3527318/
https://www.ncbi.nlm.nih.gov/pubmed/22898979
http://dx.doi.org/10.4161/org.21816
_version_ 1782253696748355584
author Moggio, Aldo
D'Armento, Giuseppe
Bussolati, Benedetta
author_facet Moggio, Aldo
D'Armento, Giuseppe
Bussolati, Benedetta
author_sort Moggio, Aldo
collection PubMed
description Different approaches for the isolation of stem/progenitor cells have been reported, including stem cell selection in stringent culture conditions. We evaluated the possibility of isolating human progenitor cells from surgical specimens preserved by under vacuum sealing and cooling, a clinical practice approached by several hospitals as alternative to formalin. Renal tissue samples (n = 20) maintained under vacuum from 6 to 48 h at 4°C were used to isolate human renal CD133(+) progenitor cells. We obtained CD133(+) progenitors from unsorted cells derived from disaggregated tissues from each sample. Phenotypic characterization as well as in vitro and in vivo differentiation of the obtained CD133(+) lines showed results comparable with sorted CD133(+) cells obtained from fresh tissue. These results indicate that the process of sealing under vacuum and cooling appears as a suitable tissue treatment to isolate hypoxia resistant cells, such as human stem/progenitor cells, and that this procedure can be exploited to render the extraction of stem cells from human samples more practical and feasible.
format Online
Article
Text
id pubmed-3527318
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Landes Bioscience
record_format MEDLINE/PubMed
spelling pubmed-35273182012-12-24 Efficient stem cell isolation from under vacuum preserved tissue samples Moggio, Aldo D'Armento, Giuseppe Bussolati, Benedetta Organogenesis Research Paper Different approaches for the isolation of stem/progenitor cells have been reported, including stem cell selection in stringent culture conditions. We evaluated the possibility of isolating human progenitor cells from surgical specimens preserved by under vacuum sealing and cooling, a clinical practice approached by several hospitals as alternative to formalin. Renal tissue samples (n = 20) maintained under vacuum from 6 to 48 h at 4°C were used to isolate human renal CD133(+) progenitor cells. We obtained CD133(+) progenitors from unsorted cells derived from disaggregated tissues from each sample. Phenotypic characterization as well as in vitro and in vivo differentiation of the obtained CD133(+) lines showed results comparable with sorted CD133(+) cells obtained from fresh tissue. These results indicate that the process of sealing under vacuum and cooling appears as a suitable tissue treatment to isolate hypoxia resistant cells, such as human stem/progenitor cells, and that this procedure can be exploited to render the extraction of stem cells from human samples more practical and feasible. Landes Bioscience 2012-07-01 /pmc/articles/PMC3527318/ /pubmed/22898979 http://dx.doi.org/10.4161/org.21816 Text en Copyright © 2012 Landes Bioscience http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License. The article may be redistributed, reproduced, and reused for non-commercial purposes, provided the original source is properly cited.
spellingShingle Research Paper
Moggio, Aldo
D'Armento, Giuseppe
Bussolati, Benedetta
Efficient stem cell isolation from under vacuum preserved tissue samples
title Efficient stem cell isolation from under vacuum preserved tissue samples
title_full Efficient stem cell isolation from under vacuum preserved tissue samples
title_fullStr Efficient stem cell isolation from under vacuum preserved tissue samples
title_full_unstemmed Efficient stem cell isolation from under vacuum preserved tissue samples
title_short Efficient stem cell isolation from under vacuum preserved tissue samples
title_sort efficient stem cell isolation from under vacuum preserved tissue samples
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3527318/
https://www.ncbi.nlm.nih.gov/pubmed/22898979
http://dx.doi.org/10.4161/org.21816
work_keys_str_mv AT moggioaldo efficientstemcellisolationfromundervacuumpreservedtissuesamples
AT darmentogiuseppe efficientstemcellisolationfromundervacuumpreservedtissuesamples
AT bussolatibenedetta efficientstemcellisolationfromundervacuumpreservedtissuesamples