Lower versus Higher Oxygen Concentration for Delivery Room Stabilisation of Preterm Neonates: Systematic Review

BACKGROUND: Emerging evidence suggests that initiating delivery room respiratory support or resuscitation for term infants using lower rather than higher concentrations of oxygen reduces mortality and the risk of serious morbidity. Uncertainty exists with regard to applicability of this strategy for...

Descripción completa

Detalles Bibliográficos
Autores principales: Brown, Jennifer V. E., Moe-Byrne, Thirimon, Harden, Melissa, McGuire, William
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3527365/
https://www.ncbi.nlm.nih.gov/pubmed/23284861
http://dx.doi.org/10.1371/journal.pone.0052033
_version_ 1782253706796859392
author Brown, Jennifer V. E.
Moe-Byrne, Thirimon
Harden, Melissa
McGuire, William
author_facet Brown, Jennifer V. E.
Moe-Byrne, Thirimon
Harden, Melissa
McGuire, William
author_sort Brown, Jennifer V. E.
collection PubMed
description BACKGROUND: Emerging evidence suggests that initiating delivery room respiratory support or resuscitation for term infants using lower rather than higher concentrations of oxygen reduces mortality and the risk of serious morbidity. Uncertainty exists with regard to applicability of this strategy for preterm infants who have different underlying reasons for respiratory distress and risks for harm at birth than term infants. METHODS: We performed a systematic review and meta-analysis of randomised controlled trials to determine the effect on mortality and morbidity of using lower (21– 50%) versus higher (>50%) oxygen concentrations for delivery room transition support of preterm infants. RESULTS: We identified six randomised controlled trials in which a total of 484 infants participated. Most participants were preterm infants born before 32 weeks’ gestation. One trial was quasi-randomised and in one trial allocation concealment was not described. Clinicians and investigators were aware of the interventions in all but one trial. Meta-analyses found a statistically significant reduction in the risk of death pooled risk ratio 0.65 (95% confidence interval 0.43, 0.98), but this effect disappeared when only the four trials with adequate allocation concealment were included [pooled risk ratio 1.0 (95% confidence interval 0.45, 2.24)]. None of the trials has evaluated any neuro-developmental outcomes. CONCLUSIONS: The available trial data do not provide strong evidence that using lower versus higher oxygen concentrations for delivery room transition support for preterm infants confers important benefits or harms. Lack of allocation concealment and blinding of clinicians and assessors are the major sources of bias in the existing trials. Further, large, good-quality trials are needed to resolve on-going uncertainties and inform clinical practice.
format Online
Article
Text
id pubmed-3527365
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-35273652013-01-02 Lower versus Higher Oxygen Concentration for Delivery Room Stabilisation of Preterm Neonates: Systematic Review Brown, Jennifer V. E. Moe-Byrne, Thirimon Harden, Melissa McGuire, William PLoS One Research Article BACKGROUND: Emerging evidence suggests that initiating delivery room respiratory support or resuscitation for term infants using lower rather than higher concentrations of oxygen reduces mortality and the risk of serious morbidity. Uncertainty exists with regard to applicability of this strategy for preterm infants who have different underlying reasons for respiratory distress and risks for harm at birth than term infants. METHODS: We performed a systematic review and meta-analysis of randomised controlled trials to determine the effect on mortality and morbidity of using lower (21– 50%) versus higher (>50%) oxygen concentrations for delivery room transition support of preterm infants. RESULTS: We identified six randomised controlled trials in which a total of 484 infants participated. Most participants were preterm infants born before 32 weeks’ gestation. One trial was quasi-randomised and in one trial allocation concealment was not described. Clinicians and investigators were aware of the interventions in all but one trial. Meta-analyses found a statistically significant reduction in the risk of death pooled risk ratio 0.65 (95% confidence interval 0.43, 0.98), but this effect disappeared when only the four trials with adequate allocation concealment were included [pooled risk ratio 1.0 (95% confidence interval 0.45, 2.24)]. None of the trials has evaluated any neuro-developmental outcomes. CONCLUSIONS: The available trial data do not provide strong evidence that using lower versus higher oxygen concentrations for delivery room transition support for preterm infants confers important benefits or harms. Lack of allocation concealment and blinding of clinicians and assessors are the major sources of bias in the existing trials. Further, large, good-quality trials are needed to resolve on-going uncertainties and inform clinical practice. Public Library of Science 2012-12-20 /pmc/articles/PMC3527365/ /pubmed/23284861 http://dx.doi.org/10.1371/journal.pone.0052033 Text en © 2012 Brown et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Brown, Jennifer V. E.
Moe-Byrne, Thirimon
Harden, Melissa
McGuire, William
Lower versus Higher Oxygen Concentration for Delivery Room Stabilisation of Preterm Neonates: Systematic Review
title Lower versus Higher Oxygen Concentration for Delivery Room Stabilisation of Preterm Neonates: Systematic Review
title_full Lower versus Higher Oxygen Concentration for Delivery Room Stabilisation of Preterm Neonates: Systematic Review
title_fullStr Lower versus Higher Oxygen Concentration for Delivery Room Stabilisation of Preterm Neonates: Systematic Review
title_full_unstemmed Lower versus Higher Oxygen Concentration for Delivery Room Stabilisation of Preterm Neonates: Systematic Review
title_short Lower versus Higher Oxygen Concentration for Delivery Room Stabilisation of Preterm Neonates: Systematic Review
title_sort lower versus higher oxygen concentration for delivery room stabilisation of preterm neonates: systematic review
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3527365/
https://www.ncbi.nlm.nih.gov/pubmed/23284861
http://dx.doi.org/10.1371/journal.pone.0052033
work_keys_str_mv AT brownjenniferve lowerversushigheroxygenconcentrationfordeliveryroomstabilisationofpretermneonatessystematicreview
AT moebyrnethirimon lowerversushigheroxygenconcentrationfordeliveryroomstabilisationofpretermneonatessystematicreview
AT hardenmelissa lowerversushigheroxygenconcentrationfordeliveryroomstabilisationofpretermneonatessystematicreview
AT mcguirewilliam lowerversushigheroxygenconcentrationfordeliveryroomstabilisationofpretermneonatessystematicreview