Central venous catheter-related superior vena cava syndrome following renal transplantation -A case report-

A 55-year-old man with end-stage renal disease had severe left ventricular dysfunction and a history of deep vein thrombosis. He underwent renal transplantation, during which a central venous catheter was inserted into the right jugular vein. The central venous pressure (CVP) exceeded 20 mmHg throug...