Cargando…
Confocal Laser Endomicroscopy for the Morphometric Evaluation of Microvessels in Human Colorectal Cancer Using Targeted Anti-CD31 Antibodies
INTRODUCTION: Numerous anti-angiogenic agents are currently developed to limit tumor growth and metastasis. While these drugs offer hope for cancer patients, their transient effect on tumor vasculature is difficult to assess in clinical settings. Confocal laser endomicroscopy (CLE) is a novel endosc...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3532115/ https://www.ncbi.nlm.nih.gov/pubmed/23285192 http://dx.doi.org/10.1371/journal.pone.0052815 |
_version_ | 1782254252408700928 |
---|---|
author | Cârţână, Tatiana Săftoiu, Adrian Gruionu, Lucian Gheorghe Gheonea, Dan Ionuţ Pirici, Daniel Georgescu, Claudia Valentina Ciocâlteu, Adriana Gruionu, Gabriel |
author_facet | Cârţână, Tatiana Săftoiu, Adrian Gruionu, Lucian Gheorghe Gheonea, Dan Ionuţ Pirici, Daniel Georgescu, Claudia Valentina Ciocâlteu, Adriana Gruionu, Gabriel |
author_sort | Cârţână, Tatiana |
collection | PubMed |
description | INTRODUCTION: Numerous anti-angiogenic agents are currently developed to limit tumor growth and metastasis. While these drugs offer hope for cancer patients, their transient effect on tumor vasculature is difficult to assess in clinical settings. Confocal laser endomicroscopy (CLE) is a novel endoscopic imaging technology that enables histological examination of the gastrointestinal mucosa. The aim of the present study was to evaluate the feasibility of using CLE to image the vascular network in fresh biopsies of human colorectal tissue. For this purpose we have imaged normal and malignant biopsy tissue samples and compared the vascular network parameters obtained with CLE with established histopathology techniques. MATERIALS AND METHODS: Fresh non-fixed biopsy samples of both normal and malignant colorectal mucosa were stained with fluorescently labeled anti-CD31 antibodies and imaged by CLE using a dedicated endomicroscopy system. Corresponding biopsy samples underwent immunohistochemical staining for CD31, assessing the microvessel density (MVD) and vascular areas for comparison with CLE data, which were measured offline using specific software. RESULTS: The vessels were imaged by CLE in both normal and tumor samples. The average diameter of normal vessels was 8.5±0.9 µm whereas in tumor samples it was 13.5±0.7 µm (p = 0.0049). Vascular density was 188.7±24.9 vessels/mm(2) in the normal tissue vs. 242.4±16.1 vessels/mm(2) in the colorectal cancer samples (p = 0.1201). In the immunohistochemistry samples, the MVD was 211.2±42.9/mm(2) and 351.3±39.6/mm(2) for normal and malignant mucosa, respectively. The vascular area was 2.9±0.5% of total tissue area for the normal mucosa and 8.5±2.1% for primary colorectal cancer tissue. CONCLUSION: Selective imaging of blood vessels with CLE is feasible in normal and tumor colorectal tissue by using fluorescently labeled antibodies targeted against an endothelial marker. The method could be translated into the clinical setting for monitoring of anti-angiogenic therapy. |
format | Online Article Text |
id | pubmed-3532115 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-35321152013-01-02 Confocal Laser Endomicroscopy for the Morphometric Evaluation of Microvessels in Human Colorectal Cancer Using Targeted Anti-CD31 Antibodies Cârţână, Tatiana Săftoiu, Adrian Gruionu, Lucian Gheorghe Gheonea, Dan Ionuţ Pirici, Daniel Georgescu, Claudia Valentina Ciocâlteu, Adriana Gruionu, Gabriel PLoS One Research Article INTRODUCTION: Numerous anti-angiogenic agents are currently developed to limit tumor growth and metastasis. While these drugs offer hope for cancer patients, their transient effect on tumor vasculature is difficult to assess in clinical settings. Confocal laser endomicroscopy (CLE) is a novel endoscopic imaging technology that enables histological examination of the gastrointestinal mucosa. The aim of the present study was to evaluate the feasibility of using CLE to image the vascular network in fresh biopsies of human colorectal tissue. For this purpose we have imaged normal and malignant biopsy tissue samples and compared the vascular network parameters obtained with CLE with established histopathology techniques. MATERIALS AND METHODS: Fresh non-fixed biopsy samples of both normal and malignant colorectal mucosa were stained with fluorescently labeled anti-CD31 antibodies and imaged by CLE using a dedicated endomicroscopy system. Corresponding biopsy samples underwent immunohistochemical staining for CD31, assessing the microvessel density (MVD) and vascular areas for comparison with CLE data, which were measured offline using specific software. RESULTS: The vessels were imaged by CLE in both normal and tumor samples. The average diameter of normal vessels was 8.5±0.9 µm whereas in tumor samples it was 13.5±0.7 µm (p = 0.0049). Vascular density was 188.7±24.9 vessels/mm(2) in the normal tissue vs. 242.4±16.1 vessels/mm(2) in the colorectal cancer samples (p = 0.1201). In the immunohistochemistry samples, the MVD was 211.2±42.9/mm(2) and 351.3±39.6/mm(2) for normal and malignant mucosa, respectively. The vascular area was 2.9±0.5% of total tissue area for the normal mucosa and 8.5±2.1% for primary colorectal cancer tissue. CONCLUSION: Selective imaging of blood vessels with CLE is feasible in normal and tumor colorectal tissue by using fluorescently labeled antibodies targeted against an endothelial marker. The method could be translated into the clinical setting for monitoring of anti-angiogenic therapy. Public Library of Science 2012-12-28 /pmc/articles/PMC3532115/ /pubmed/23285192 http://dx.doi.org/10.1371/journal.pone.0052815 Text en © 2012 Cârţână et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Cârţână, Tatiana Săftoiu, Adrian Gruionu, Lucian Gheorghe Gheonea, Dan Ionuţ Pirici, Daniel Georgescu, Claudia Valentina Ciocâlteu, Adriana Gruionu, Gabriel Confocal Laser Endomicroscopy for the Morphometric Evaluation of Microvessels in Human Colorectal Cancer Using Targeted Anti-CD31 Antibodies |
title | Confocal Laser Endomicroscopy for the Morphometric Evaluation of Microvessels in Human Colorectal Cancer Using Targeted Anti-CD31 Antibodies |
title_full | Confocal Laser Endomicroscopy for the Morphometric Evaluation of Microvessels in Human Colorectal Cancer Using Targeted Anti-CD31 Antibodies |
title_fullStr | Confocal Laser Endomicroscopy for the Morphometric Evaluation of Microvessels in Human Colorectal Cancer Using Targeted Anti-CD31 Antibodies |
title_full_unstemmed | Confocal Laser Endomicroscopy for the Morphometric Evaluation of Microvessels in Human Colorectal Cancer Using Targeted Anti-CD31 Antibodies |
title_short | Confocal Laser Endomicroscopy for the Morphometric Evaluation of Microvessels in Human Colorectal Cancer Using Targeted Anti-CD31 Antibodies |
title_sort | confocal laser endomicroscopy for the morphometric evaluation of microvessels in human colorectal cancer using targeted anti-cd31 antibodies |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3532115/ https://www.ncbi.nlm.nih.gov/pubmed/23285192 http://dx.doi.org/10.1371/journal.pone.0052815 |
work_keys_str_mv | AT cartanatatiana confocallaserendomicroscopyforthemorphometricevaluationofmicrovesselsinhumancolorectalcancerusingtargetedanticd31antibodies AT saftoiuadrian confocallaserendomicroscopyforthemorphometricevaluationofmicrovesselsinhumancolorectalcancerusingtargetedanticd31antibodies AT gruionuluciangheorghe confocallaserendomicroscopyforthemorphometricevaluationofmicrovesselsinhumancolorectalcancerusingtargetedanticd31antibodies AT gheoneadanionut confocallaserendomicroscopyforthemorphometricevaluationofmicrovesselsinhumancolorectalcancerusingtargetedanticd31antibodies AT piricidaniel confocallaserendomicroscopyforthemorphometricevaluationofmicrovesselsinhumancolorectalcancerusingtargetedanticd31antibodies AT georgescuclaudiavalentina confocallaserendomicroscopyforthemorphometricevaluationofmicrovesselsinhumancolorectalcancerusingtargetedanticd31antibodies AT ciocalteuadriana confocallaserendomicroscopyforthemorphometricevaluationofmicrovesselsinhumancolorectalcancerusingtargetedanticd31antibodies AT gruionugabriel confocallaserendomicroscopyforthemorphometricevaluationofmicrovesselsinhumancolorectalcancerusingtargetedanticd31antibodies |