Cargando…

Short-Term Stability in Refractive Status Despite Large Fluctuations in Glucose Levels in Diabetes Mellitus Type 1 and 2

PURPOSE: This work investigates how short-term changes in blood glucose concentration affect the refractive components of the diabetic eye in patients with long-term Type 1 and Type 2 diabetes. METHODS: Blood glucose concentration, refractive error components (mean spherical equivalent MSE, J0, J45)...

Descripción completa

Detalles Bibliográficos
Autores principales: Huntjens, Byki, Charman, W. Neil, Workman, Helena, Hosking, Sarah L., O’Donnell, Clare
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3532445/
https://www.ncbi.nlm.nih.gov/pubmed/23285232
http://dx.doi.org/10.1371/journal.pone.0052947
_version_ 1782254314296705024
author Huntjens, Byki
Charman, W. Neil
Workman, Helena
Hosking, Sarah L.
O’Donnell, Clare
author_facet Huntjens, Byki
Charman, W. Neil
Workman, Helena
Hosking, Sarah L.
O’Donnell, Clare
author_sort Huntjens, Byki
collection PubMed
description PURPOSE: This work investigates how short-term changes in blood glucose concentration affect the refractive components of the diabetic eye in patients with long-term Type 1 and Type 2 diabetes. METHODS: Blood glucose concentration, refractive error components (mean spherical equivalent MSE, J0, J45), central corneal thickness (CCT), anterior chamber depth (ACD), crystalline lens thickness (LT), axial length (AL) and ocular aberrations were monitored at two-hourly intervals over a 12-hour period in: 20 T1DM patients (mean age ± SD) 38±14 years, baseline HbA1c 8.6±1.9%; 21 T2DM patients (mean age ± SD) 56±11 years, HbA1c 7.5±1.8%; and in 20 control subjects (mean age ± SD) 49±23 years, HbA1c 5.5±0.5%. The refractive and biometric results were compared with the corresponding changes in blood glucose concentration. RESULTS: Blood glucose concentration at different times was found to vary significantly within (p<0.0005) and between groups (p<0.0005). However, the refractive error components and ocular aberrations were not found to alter significantly over the day in either the diabetic patients or the control subjects (p>0.05). Minor changes of marginal statistical or optical significance were observed in some biometric parameters. Similarly there were some marginally significant differences between the baseline biometric parameters of well-controlled and poorly-controlled diabetic subjects. CONCLUSION: This work suggests that normal, short-term fluctuations (of up to about 6 mM/l on a timescale of a few hours) in the blood glucose levels of diabetics are not usually associated with acute changes in refractive error or ocular wavefront aberrations. It is therefore possible that factors other than refractive error fluctuations are sometimes responsible for the transient visual problems often reported by diabetic patients.
format Online
Article
Text
id pubmed-3532445
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-35324452013-01-02 Short-Term Stability in Refractive Status Despite Large Fluctuations in Glucose Levels in Diabetes Mellitus Type 1 and 2 Huntjens, Byki Charman, W. Neil Workman, Helena Hosking, Sarah L. O’Donnell, Clare PLoS One Research Article PURPOSE: This work investigates how short-term changes in blood glucose concentration affect the refractive components of the diabetic eye in patients with long-term Type 1 and Type 2 diabetes. METHODS: Blood glucose concentration, refractive error components (mean spherical equivalent MSE, J0, J45), central corneal thickness (CCT), anterior chamber depth (ACD), crystalline lens thickness (LT), axial length (AL) and ocular aberrations were monitored at two-hourly intervals over a 12-hour period in: 20 T1DM patients (mean age ± SD) 38±14 years, baseline HbA1c 8.6±1.9%; 21 T2DM patients (mean age ± SD) 56±11 years, HbA1c 7.5±1.8%; and in 20 control subjects (mean age ± SD) 49±23 years, HbA1c 5.5±0.5%. The refractive and biometric results were compared with the corresponding changes in blood glucose concentration. RESULTS: Blood glucose concentration at different times was found to vary significantly within (p<0.0005) and between groups (p<0.0005). However, the refractive error components and ocular aberrations were not found to alter significantly over the day in either the diabetic patients or the control subjects (p>0.05). Minor changes of marginal statistical or optical significance were observed in some biometric parameters. Similarly there were some marginally significant differences between the baseline biometric parameters of well-controlled and poorly-controlled diabetic subjects. CONCLUSION: This work suggests that normal, short-term fluctuations (of up to about 6 mM/l on a timescale of a few hours) in the blood glucose levels of diabetics are not usually associated with acute changes in refractive error or ocular wavefront aberrations. It is therefore possible that factors other than refractive error fluctuations are sometimes responsible for the transient visual problems often reported by diabetic patients. Public Library of Science 2012-12-28 /pmc/articles/PMC3532445/ /pubmed/23285232 http://dx.doi.org/10.1371/journal.pone.0052947 Text en © 2012 Huntjens et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Huntjens, Byki
Charman, W. Neil
Workman, Helena
Hosking, Sarah L.
O’Donnell, Clare
Short-Term Stability in Refractive Status Despite Large Fluctuations in Glucose Levels in Diabetes Mellitus Type 1 and 2
title Short-Term Stability in Refractive Status Despite Large Fluctuations in Glucose Levels in Diabetes Mellitus Type 1 and 2
title_full Short-Term Stability in Refractive Status Despite Large Fluctuations in Glucose Levels in Diabetes Mellitus Type 1 and 2
title_fullStr Short-Term Stability in Refractive Status Despite Large Fluctuations in Glucose Levels in Diabetes Mellitus Type 1 and 2
title_full_unstemmed Short-Term Stability in Refractive Status Despite Large Fluctuations in Glucose Levels in Diabetes Mellitus Type 1 and 2
title_short Short-Term Stability in Refractive Status Despite Large Fluctuations in Glucose Levels in Diabetes Mellitus Type 1 and 2
title_sort short-term stability in refractive status despite large fluctuations in glucose levels in diabetes mellitus type 1 and 2
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3532445/
https://www.ncbi.nlm.nih.gov/pubmed/23285232
http://dx.doi.org/10.1371/journal.pone.0052947
work_keys_str_mv AT huntjensbyki shorttermstabilityinrefractivestatusdespitelargefluctuationsinglucoselevelsindiabetesmellitustype1and2
AT charmanwneil shorttermstabilityinrefractivestatusdespitelargefluctuationsinglucoselevelsindiabetesmellitustype1and2
AT workmanhelena shorttermstabilityinrefractivestatusdespitelargefluctuationsinglucoselevelsindiabetesmellitustype1and2
AT hoskingsarahl shorttermstabilityinrefractivestatusdespitelargefluctuationsinglucoselevelsindiabetesmellitustype1and2
AT odonnellclare shorttermstabilityinrefractivestatusdespitelargefluctuationsinglucoselevelsindiabetesmellitustype1and2