Reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the Born in Bradford study
West J, Manchester B, Wright J, Lawlor DA, Waiblinger D. Reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the Born in Bradford study. Paediatric and Perinatal Epidemiology 2011. Assessing neonatal size r...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Blackwell Publishing Ltd
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3532621/ https://www.ncbi.nlm.nih.gov/pubmed/21281329 http://dx.doi.org/10.1111/j.1365-3016.2010.01181.x |
_version_ | 1782254328646467584 |
---|---|
author | West, Jane Manchester, Ben Wright, John Lawlor, Debbie A Waiblinger, Dagmar |
author_facet | West, Jane Manchester, Ben Wright, John Lawlor, Debbie A Waiblinger, Dagmar |
author_sort | West, Jane |
collection | PubMed |
description | West J, Manchester B, Wright J, Lawlor DA, Waiblinger D. Reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the Born in Bradford study. Paediatric and Perinatal Epidemiology 2011. Assessing neonatal size reliably is important for research and clinical practice. The aim of this study was to examine the reliability of routine clinical measurements of neonatal circumferences and of skinfold thicknesses assessed for research purposes. All measurements were undertaken on the same population of neonates born in a large maternity unit in Bradford, UK. Technical error of measurement (TEM), relative TEM and the coefficient of reliability are reported. Intra-observer TEMs for routine circumference measurements were all below 0.4 cm and were generally within ±2-times the mean. Inter-observer TEM ranged from 0.20 to 0.36 cm for head circumference, 0.19 to 0.39 cm for mid upper arm circumference and from 0.39 to 0.77 cm for abdominal circumference. Intra and inter-observer TEM for triceps skinfold thickness ranged from 0.22 to 0.35 mm and 0.15 to 0.54 mm, respectively. Subscapular skinfold thickness TEM values were 0.14 to 0.25 mm for intra-observer measurements and 0.17 to 0.63 mm for inter-observer measurements. Relative TEM values for routine circumferences were all below 4.00% but varied between 2.88% and 14.23% for research skinfold measurements. Reliability was mostly between 80% and 99% for routine circumference measurements and ≥70% for most research skinfold measurements. Routine clinical measurements of neonatal circumferences are reliably assessed in Bradford. Assessing skinfolds in neonates has variable reliability, but on the whole is good. The greater intra-observer, compared with inter-observer, reliability for both sets of measurements highlights the importance of having a minimal number of assessors whenever possible. |
format | Online Article Text |
id | pubmed-3532621 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Blackwell Publishing Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-35326212013-01-09 Reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the Born in Bradford study West, Jane Manchester, Ben Wright, John Lawlor, Debbie A Waiblinger, Dagmar Paediatr Perinat Epidemiol Infant Anthropometry West J, Manchester B, Wright J, Lawlor DA, Waiblinger D. Reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the Born in Bradford study. Paediatric and Perinatal Epidemiology 2011. Assessing neonatal size reliably is important for research and clinical practice. The aim of this study was to examine the reliability of routine clinical measurements of neonatal circumferences and of skinfold thicknesses assessed for research purposes. All measurements were undertaken on the same population of neonates born in a large maternity unit in Bradford, UK. Technical error of measurement (TEM), relative TEM and the coefficient of reliability are reported. Intra-observer TEMs for routine circumference measurements were all below 0.4 cm and were generally within ±2-times the mean. Inter-observer TEM ranged from 0.20 to 0.36 cm for head circumference, 0.19 to 0.39 cm for mid upper arm circumference and from 0.39 to 0.77 cm for abdominal circumference. Intra and inter-observer TEM for triceps skinfold thickness ranged from 0.22 to 0.35 mm and 0.15 to 0.54 mm, respectively. Subscapular skinfold thickness TEM values were 0.14 to 0.25 mm for intra-observer measurements and 0.17 to 0.63 mm for inter-observer measurements. Relative TEM values for routine circumferences were all below 4.00% but varied between 2.88% and 14.23% for research skinfold measurements. Reliability was mostly between 80% and 99% for routine circumference measurements and ≥70% for most research skinfold measurements. Routine clinical measurements of neonatal circumferences are reliably assessed in Bradford. Assessing skinfolds in neonates has variable reliability, but on the whole is good. The greater intra-observer, compared with inter-observer, reliability for both sets of measurements highlights the importance of having a minimal number of assessors whenever possible. Blackwell Publishing Ltd 2011-03 2011-01-24 /pmc/articles/PMC3532621/ /pubmed/21281329 http://dx.doi.org/10.1111/j.1365-3016.2010.01181.x Text en © 2011 Blackwell Publishing Ltd. http://creativecommons.org/licenses/by/2.5/ Re-use of this article is permitted in accordance with the Creative Commons Deed, Attribution 2.5, which does not permit commercial exploitation. |
spellingShingle | Infant Anthropometry West, Jane Manchester, Ben Wright, John Lawlor, Debbie A Waiblinger, Dagmar Reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the Born in Bradford study |
title | Reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the Born in Bradford study |
title_full | Reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the Born in Bradford study |
title_fullStr | Reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the Born in Bradford study |
title_full_unstemmed | Reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the Born in Bradford study |
title_short | Reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the Born in Bradford study |
title_sort | reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the born in bradford study |
topic | Infant Anthropometry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3532621/ https://www.ncbi.nlm.nih.gov/pubmed/21281329 http://dx.doi.org/10.1111/j.1365-3016.2010.01181.x |
work_keys_str_mv | AT westjane reliabilityofroutineclinicalmeasurementsofneonatalcircumferencesandresearchmeasurementsofneonatalskinfoldthicknessesfindingsfromtheborninbradfordstudy AT manchesterben reliabilityofroutineclinicalmeasurementsofneonatalcircumferencesandresearchmeasurementsofneonatalskinfoldthicknessesfindingsfromtheborninbradfordstudy AT wrightjohn reliabilityofroutineclinicalmeasurementsofneonatalcircumferencesandresearchmeasurementsofneonatalskinfoldthicknessesfindingsfromtheborninbradfordstudy AT lawlordebbiea reliabilityofroutineclinicalmeasurementsofneonatalcircumferencesandresearchmeasurementsofneonatalskinfoldthicknessesfindingsfromtheborninbradfordstudy AT waiblingerdagmar reliabilityofroutineclinicalmeasurementsofneonatalcircumferencesandresearchmeasurementsofneonatalskinfoldthicknessesfindingsfromtheborninbradfordstudy |