Cargando…

The Effect of File Size on the Accuracy of the Raypex 5 Apex Locator: An In Vitro Study

BACKGROUND AND AIMS: Determining the proper length of the root canals is essential for successful endodontic treatment. The purpose of this in vitro study was to evaluate the effect of file size on the accuracy of the Raypex 5 electronic apex locator for working length determination of uninstrumente...

Descripción completa

Detalles Bibliográficos
Autores principales: Sadeghi, Shiva, Abolghasemi, Masoomeh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tabriz University of Medical Sciences 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3533634/
https://www.ncbi.nlm.nih.gov/pubmed/23285326
http://dx.doi.org/10.5681/joddd.2008.005
_version_ 1782254436042670080
author Sadeghi, Shiva
Abolghasemi, Masoomeh
author_facet Sadeghi, Shiva
Abolghasemi, Masoomeh
author_sort Sadeghi, Shiva
collection PubMed
description BACKGROUND AND AIMS: Determining the proper length of the root canals is essential for successful endodontic treatment. The purpose of this in vitro study was to evaluate the effect of file size on the accuracy of the Raypex 5 electronic apex locator for working length determination of uninstrumented canals. MATERIALS AND METHODS: Twenty maxillary central incisors with single straight canals were used. Following access cavity preparation, electronic working length by means of Raypex 5 apex locator and actual working length were determined. Data were analyzed using ANOVA with repeated measurements and LSD test. RESULTS: There was no significant difference between electronic and actual working lengths when a size 15 K-file was used. CONCLUSION: Under the conditions of the present study, a size 15 K-file is a more suitable size for de-termining working length.
format Online
Article
Text
id pubmed-3533634
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher Tabriz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-35336342013-01-02 The Effect of File Size on the Accuracy of the Raypex 5 Apex Locator: An In Vitro Study Sadeghi, Shiva Abolghasemi, Masoomeh J Dent Res Dent Clin Dent Prospects Original Article BACKGROUND AND AIMS: Determining the proper length of the root canals is essential for successful endodontic treatment. The purpose of this in vitro study was to evaluate the effect of file size on the accuracy of the Raypex 5 electronic apex locator for working length determination of uninstrumented canals. MATERIALS AND METHODS: Twenty maxillary central incisors with single straight canals were used. Following access cavity preparation, electronic working length by means of Raypex 5 apex locator and actual working length were determined. Data were analyzed using ANOVA with repeated measurements and LSD test. RESULTS: There was no significant difference between electronic and actual working lengths when a size 15 K-file was used. CONCLUSION: Under the conditions of the present study, a size 15 K-file is a more suitable size for de-termining working length. Tabriz University of Medical Sciences 2008 2008-05-15 /pmc/articles/PMC3533634/ /pubmed/23285326 http://dx.doi.org/10.5681/joddd.2008.005 Text en
spellingShingle Original Article
Sadeghi, Shiva
Abolghasemi, Masoomeh
The Effect of File Size on the Accuracy of the Raypex 5 Apex Locator: An In Vitro Study
title The Effect of File Size on the Accuracy of the Raypex 5 Apex Locator: An In Vitro Study
title_full The Effect of File Size on the Accuracy of the Raypex 5 Apex Locator: An In Vitro Study
title_fullStr The Effect of File Size on the Accuracy of the Raypex 5 Apex Locator: An In Vitro Study
title_full_unstemmed The Effect of File Size on the Accuracy of the Raypex 5 Apex Locator: An In Vitro Study
title_short The Effect of File Size on the Accuracy of the Raypex 5 Apex Locator: An In Vitro Study
title_sort effect of file size on the accuracy of the raypex 5 apex locator: an in vitro study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3533634/
https://www.ncbi.nlm.nih.gov/pubmed/23285326
http://dx.doi.org/10.5681/joddd.2008.005
work_keys_str_mv AT sadeghishiva theeffectoffilesizeontheaccuracyoftheraypex5apexlocatoraninvitrostudy
AT abolghasemimasoomeh theeffectoffilesizeontheaccuracyoftheraypex5apexlocatoraninvitrostudy
AT sadeghishiva effectoffilesizeontheaccuracyoftheraypex5apexlocatoraninvitrostudy
AT abolghasemimasoomeh effectoffilesizeontheaccuracyoftheraypex5apexlocatoraninvitrostudy