Cardiovascular magnetic resonance physics for clinicians: part II

This is the second of two reviews that is intended to cover the essential aspects of cardiovascular magnetic resonance (CMR) physics in a way that is understandable and relevant to clinicians using CMR in their daily practice. Starting with the basic pulse sequences and contrast mechanisms described...

Descripción completa

Detalles Bibliográficos
Autores principales: Biglands, John D, Radjenovic, Aleksandra, Ridgway, John P
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3533879/
https://www.ncbi.nlm.nih.gov/pubmed/22995744
http://dx.doi.org/10.1186/1532-429X-14-66
_version_ 1782254474088153088
author Biglands, John D
Radjenovic, Aleksandra
Ridgway, John P
author_facet Biglands, John D
Radjenovic, Aleksandra
Ridgway, John P
author_sort Biglands, John D
collection PubMed
description This is the second of two reviews that is intended to cover the essential aspects of cardiovascular magnetic resonance (CMR) physics in a way that is understandable and relevant to clinicians using CMR in their daily practice. Starting with the basic pulse sequences and contrast mechanisms described in part I, it briefly discusses further approaches to accelerate image acquisition. It then continues by showing in detail how the contrast behaviour of black blood fast spin echo and bright blood cine gradient echo techniques can be modified by adding rf preparation pulses to derive a number of more specialised pulse sequences. The simplest examples described include T2-weighted oedema imaging, fat suppression and myocardial tagging cine pulse sequences. Two further important derivatives of the gradient echo pulse sequence, obtained by adding preparation pulses, are used in combination with the administration of a gadolinium-based contrast agent for myocardial perfusion imaging and the assessment of myocardial tissue viability using a late gadolinium enhancement (LGE) technique. These two imaging techniques are discussed in more detail, outlining the basic principles of each pulse sequence, the practical steps required to achieve the best results in a clinical setting and, in the case of perfusion, explaining some of the factors that influence current approaches to perfusion image analysis. The key principles of contrast-enhanced magnetic resonance angiography (CE-MRA) are also explained in detail, especially focusing on timing of the acquisition following contrast agent bolus administration, and current approaches to achieving time resolved MRA. Alternative MRA techniques that do not require the use of an endogenous contrast agent are summarised, and the specialised pulse sequence used to image the coronary arteries, using respiratory navigator gating, is described in detail. The article concludes by explaining the principle behind phase contrast imaging techniques which create images that represent the phase of the MR signal rather than the magnitude. It is shown how this principle can be used to generate velocity maps by designing gradient waveforms that give rise to a relative phase change that is proportional to velocity. Choice of velocity encoding range and key pitfalls in the use of this technique are discussed.
format Online
Article
Text
id pubmed-3533879
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-35338792013-01-07 Cardiovascular magnetic resonance physics for clinicians: part II Biglands, John D Radjenovic, Aleksandra Ridgway, John P J Cardiovasc Magn Reson Review This is the second of two reviews that is intended to cover the essential aspects of cardiovascular magnetic resonance (CMR) physics in a way that is understandable and relevant to clinicians using CMR in their daily practice. Starting with the basic pulse sequences and contrast mechanisms described in part I, it briefly discusses further approaches to accelerate image acquisition. It then continues by showing in detail how the contrast behaviour of black blood fast spin echo and bright blood cine gradient echo techniques can be modified by adding rf preparation pulses to derive a number of more specialised pulse sequences. The simplest examples described include T2-weighted oedema imaging, fat suppression and myocardial tagging cine pulse sequences. Two further important derivatives of the gradient echo pulse sequence, obtained by adding preparation pulses, are used in combination with the administration of a gadolinium-based contrast agent for myocardial perfusion imaging and the assessment of myocardial tissue viability using a late gadolinium enhancement (LGE) technique. These two imaging techniques are discussed in more detail, outlining the basic principles of each pulse sequence, the practical steps required to achieve the best results in a clinical setting and, in the case of perfusion, explaining some of the factors that influence current approaches to perfusion image analysis. The key principles of contrast-enhanced magnetic resonance angiography (CE-MRA) are also explained in detail, especially focusing on timing of the acquisition following contrast agent bolus administration, and current approaches to achieving time resolved MRA. Alternative MRA techniques that do not require the use of an endogenous contrast agent are summarised, and the specialised pulse sequence used to image the coronary arteries, using respiratory navigator gating, is described in detail. The article concludes by explaining the principle behind phase contrast imaging techniques which create images that represent the phase of the MR signal rather than the magnitude. It is shown how this principle can be used to generate velocity maps by designing gradient waveforms that give rise to a relative phase change that is proportional to velocity. Choice of velocity encoding range and key pitfalls in the use of this technique are discussed. BioMed Central 2012-09-20 /pmc/articles/PMC3533879/ /pubmed/22995744 http://dx.doi.org/10.1186/1532-429X-14-66 Text en Copyright ©2012 Biglands et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review
Biglands, John D
Radjenovic, Aleksandra
Ridgway, John P
Cardiovascular magnetic resonance physics for clinicians: part II
title Cardiovascular magnetic resonance physics for clinicians: part II
title_full Cardiovascular magnetic resonance physics for clinicians: part II
title_fullStr Cardiovascular magnetic resonance physics for clinicians: part II
title_full_unstemmed Cardiovascular magnetic resonance physics for clinicians: part II
title_short Cardiovascular magnetic resonance physics for clinicians: part II
title_sort cardiovascular magnetic resonance physics for clinicians: part ii
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3533879/
https://www.ncbi.nlm.nih.gov/pubmed/22995744
http://dx.doi.org/10.1186/1532-429X-14-66
work_keys_str_mv AT biglandsjohnd cardiovascularmagneticresonancephysicsforclinicianspartii
AT radjenovicaleksandra cardiovascularmagneticresonancephysicsforclinicianspartii
AT ridgwayjohnp cardiovascularmagneticresonancephysicsforclinicianspartii