Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study
PURPOSE: This study was performed to compare the inverted digital images and film-based images of dry pig mandibles to measure the periodontal bone defect depth. MATERIALS AND METHODS: Forty 2-wall bone defects were made in the proximal region of the premolar in the dry pig mandibles. The digital an...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Oral and Maxillofacial Radiology
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3534179/ https://www.ncbi.nlm.nih.gov/pubmed/23301211 http://dx.doi.org/10.5624/isd.2012.42.4.243 |
_version_ | 1782475287978573824 |
---|---|
author | de Molon, Rafael Scaf Morais-Camillo, Juliana Aparecida Najarro Dearo Sakakura, Celso Eduardo Ferreira, Mauricio Goncalves Loffredo, Leonor Castro Monteiro Scaf, Gulnara |
author_facet | de Molon, Rafael Scaf Morais-Camillo, Juliana Aparecida Najarro Dearo Sakakura, Celso Eduardo Ferreira, Mauricio Goncalves Loffredo, Leonor Castro Monteiro Scaf, Gulnara |
author_sort | de Molon, Rafael Scaf |
collection | PubMed |
description | PURPOSE: This study was performed to compare the inverted digital images and film-based images of dry pig mandibles to measure the periodontal bone defect depth. MATERIALS AND METHODS: Forty 2-wall bone defects were made in the proximal region of the premolar in the dry pig mandibles. The digital and conventional radiographs were taken using a Schick sensor and Kodak F-speed intraoral film. Image manipulation (inversion) was performed using Adobe Photoshop 7.0 software. Four trained examiners made all of the radiographic measurements in millimeters a total of three times from the cementoenamel junction to the most apical extension of the bone loss with both types of images: inverted digital and film. The measurements were also made in dry mandibles using a periodontal probe and digital caliper. The Student's t-test was used to compare the depth measurements obtained from the two types of images and direct visual measurement in the dry mandibles. A significance level of 0.05 for a 95% confidence interval was used for each comparison. RESULTS: There was a significant difference between depth measurements in the inverted digital images and direct visual measurements (p>|t|=0.0039), with means of 6.29 mm (IC(95%):6.04-6.54) and 6.79 mm (IC(95%):6.45-7.11), respectively. There was a non-significant difference between the film-based radiographs and direct visual measurements (p>|t|=0.4950), with means of 6.64mm(IC(95%):6.40-6.89) and 6.79mm(IC(95%):6.45-7.11), respectively. CONCLUSION: The periodontal bone defect measurements in the inverted digital images were inferior to film-based radiographs, underestimating the amount of bone loss. |
format | Online Article Text |
id | pubmed-3534179 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Korean Academy of Oral and Maxillofacial Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-35341792013-01-08 Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study de Molon, Rafael Scaf Morais-Camillo, Juliana Aparecida Najarro Dearo Sakakura, Celso Eduardo Ferreira, Mauricio Goncalves Loffredo, Leonor Castro Monteiro Scaf, Gulnara Imaging Sci Dent Original Article PURPOSE: This study was performed to compare the inverted digital images and film-based images of dry pig mandibles to measure the periodontal bone defect depth. MATERIALS AND METHODS: Forty 2-wall bone defects were made in the proximal region of the premolar in the dry pig mandibles. The digital and conventional radiographs were taken using a Schick sensor and Kodak F-speed intraoral film. Image manipulation (inversion) was performed using Adobe Photoshop 7.0 software. Four trained examiners made all of the radiographic measurements in millimeters a total of three times from the cementoenamel junction to the most apical extension of the bone loss with both types of images: inverted digital and film. The measurements were also made in dry mandibles using a periodontal probe and digital caliper. The Student's t-test was used to compare the depth measurements obtained from the two types of images and direct visual measurement in the dry mandibles. A significance level of 0.05 for a 95% confidence interval was used for each comparison. RESULTS: There was a significant difference between depth measurements in the inverted digital images and direct visual measurements (p>|t|=0.0039), with means of 6.29 mm (IC(95%):6.04-6.54) and 6.79 mm (IC(95%):6.45-7.11), respectively. There was a non-significant difference between the film-based radiographs and direct visual measurements (p>|t|=0.4950), with means of 6.64mm(IC(95%):6.40-6.89) and 6.79mm(IC(95%):6.45-7.11), respectively. CONCLUSION: The periodontal bone defect measurements in the inverted digital images were inferior to film-based radiographs, underestimating the amount of bone loss. Korean Academy of Oral and Maxillofacial Radiology 2012-12 2012-12-23 /pmc/articles/PMC3534179/ /pubmed/23301211 http://dx.doi.org/10.5624/isd.2012.42.4.243 Text en Copyright © 2012 by Korean Academy of Oral and Maxillofacial Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article de Molon, Rafael Scaf Morais-Camillo, Juliana Aparecida Najarro Dearo Sakakura, Celso Eduardo Ferreira, Mauricio Goncalves Loffredo, Leonor Castro Monteiro Scaf, Gulnara Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study |
title | Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study |
title_full | Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study |
title_fullStr | Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study |
title_full_unstemmed | Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study |
title_short | Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study |
title_sort | measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3534179/ https://www.ncbi.nlm.nih.gov/pubmed/23301211 http://dx.doi.org/10.5624/isd.2012.42.4.243 |
work_keys_str_mv | AT demolonrafaelscaf measurementsofsimulatedperiodontalbonedefectsininverteddigitalimageandfilmbasedradiographaninvitrostudy AT moraiscamillojulianaaparecidanajarrodearo measurementsofsimulatedperiodontalbonedefectsininverteddigitalimageandfilmbasedradiographaninvitrostudy AT sakakuracelsoeduardo measurementsofsimulatedperiodontalbonedefectsininverteddigitalimageandfilmbasedradiographaninvitrostudy AT ferreiramauriciogoncalves measurementsofsimulatedperiodontalbonedefectsininverteddigitalimageandfilmbasedradiographaninvitrostudy AT loffredoleonorcastromonteiro measurementsofsimulatedperiodontalbonedefectsininverteddigitalimageandfilmbasedradiographaninvitrostudy AT scafgulnara measurementsofsimulatedperiodontalbonedefectsininverteddigitalimageandfilmbasedradiographaninvitrostudy |