Cargando…
Analysis of late toxicity associated with external beam radiation therapy for prostate cancer with uniform setting of classical 4-field 70 Gy in 35 fractions: a survey study by the Osaka Urological Tumor Radiotherapy Study Group
We aimed to analyse late toxicity associated with external beam radiation therapy (EBRT) for prostate cancer using uniform dose-fractionation and beam arrangement, with the focus on the effect of 3D (CT) simulation and portal field size. We collected data concerning patients with localized prostate...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3534284/ https://www.ncbi.nlm.nih.gov/pubmed/22988284 http://dx.doi.org/10.1093/jrr/rrs083 |
_version_ | 1782475308064047104 |
---|---|
author | Yoshioka, Yasuo Suzuki, Osamu Nishimura, Kazuo Inoue, Hitoshi Hara, Tsuneo Yoshida, Ken Imai, Atsushi Tsujimura, Akira Nonomura, Norio Ogawa, Kazuhiko |
author_facet | Yoshioka, Yasuo Suzuki, Osamu Nishimura, Kazuo Inoue, Hitoshi Hara, Tsuneo Yoshida, Ken Imai, Atsushi Tsujimura, Akira Nonomura, Norio Ogawa, Kazuhiko |
author_sort | Yoshioka, Yasuo |
collection | PubMed |
description | We aimed to analyse late toxicity associated with external beam radiation therapy (EBRT) for prostate cancer using uniform dose-fractionation and beam arrangement, with the focus on the effect of 3D (CT) simulation and portal field size. We collected data concerning patients with localized prostate adenocarcinoma who had been treated with EBRT at five institutions in Osaka, Japan, between 1998 and 2006. All had been treated with 70 Gy in 35 fractions, using the classical 4-field technique with gantry angles of 0°, 90°, 180° and 270°. Late toxicity was evaluated strictly in terms of the Common Terminology Criteria for Adverse Events Version 4.0. In total, 362 patients were analysed, with a median follow-up of 4.5 years (range 1.0–11.6). The 5-year overall and cause-specific survival rates were 93% and 96%, respectively. The mean ± SD portal field size in the right–left, superior–inferior, and anterior–posterior directions was, respectively, 10.8 ± 1.1, 10.2 ± 1.0 and 8.8 ± 0.9 cm for 2D simulation, and 8.4 ± 1.2, 8.2 ± 1.0 and 7.7 ± 1.0 cm for 3D simulation (P < 0.001). No Grade 4 or 5 late toxicity was observed. The actuarial 5-year Grade 2–3 genitourinary and gastrointestinal (GI) late toxicity rates were 6% and 14%, respectively, while the corresponding late rectal bleeding rate was 23% for 2D simulation and 7% for 3D simulation (P < 0.001). With a uniform setting of classical 4-field 70 Gy/35 fractions, the use of CT simulation and the resultant reduction in portal field size were significantly associated with reduced late GI toxicity, especially with less rectal bleeding. |
format | Online Article Text |
id | pubmed-3534284 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-35342842013-01-03 Analysis of late toxicity associated with external beam radiation therapy for prostate cancer with uniform setting of classical 4-field 70 Gy in 35 fractions: a survey study by the Osaka Urological Tumor Radiotherapy Study Group Yoshioka, Yasuo Suzuki, Osamu Nishimura, Kazuo Inoue, Hitoshi Hara, Tsuneo Yoshida, Ken Imai, Atsushi Tsujimura, Akira Nonomura, Norio Ogawa, Kazuhiko J Radiat Res Oncology We aimed to analyse late toxicity associated with external beam radiation therapy (EBRT) for prostate cancer using uniform dose-fractionation and beam arrangement, with the focus on the effect of 3D (CT) simulation and portal field size. We collected data concerning patients with localized prostate adenocarcinoma who had been treated with EBRT at five institutions in Osaka, Japan, between 1998 and 2006. All had been treated with 70 Gy in 35 fractions, using the classical 4-field technique with gantry angles of 0°, 90°, 180° and 270°. Late toxicity was evaluated strictly in terms of the Common Terminology Criteria for Adverse Events Version 4.0. In total, 362 patients were analysed, with a median follow-up of 4.5 years (range 1.0–11.6). The 5-year overall and cause-specific survival rates were 93% and 96%, respectively. The mean ± SD portal field size in the right–left, superior–inferior, and anterior–posterior directions was, respectively, 10.8 ± 1.1, 10.2 ± 1.0 and 8.8 ± 0.9 cm for 2D simulation, and 8.4 ± 1.2, 8.2 ± 1.0 and 7.7 ± 1.0 cm for 3D simulation (P < 0.001). No Grade 4 or 5 late toxicity was observed. The actuarial 5-year Grade 2–3 genitourinary and gastrointestinal (GI) late toxicity rates were 6% and 14%, respectively, while the corresponding late rectal bleeding rate was 23% for 2D simulation and 7% for 3D simulation (P < 0.001). With a uniform setting of classical 4-field 70 Gy/35 fractions, the use of CT simulation and the resultant reduction in portal field size were significantly associated with reduced late GI toxicity, especially with less rectal bleeding. Oxford University Press 2013-01 2012-09-17 /pmc/articles/PMC3534284/ /pubmed/22988284 http://dx.doi.org/10.1093/jrr/rrs083 Text en © The Author 2012. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Therapeutic Radiology and Oncology. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Oncology Yoshioka, Yasuo Suzuki, Osamu Nishimura, Kazuo Inoue, Hitoshi Hara, Tsuneo Yoshida, Ken Imai, Atsushi Tsujimura, Akira Nonomura, Norio Ogawa, Kazuhiko Analysis of late toxicity associated with external beam radiation therapy for prostate cancer with uniform setting of classical 4-field 70 Gy in 35 fractions: a survey study by the Osaka Urological Tumor Radiotherapy Study Group |
title | Analysis of late toxicity associated with external beam radiation therapy for prostate cancer with uniform setting of classical 4-field 70 Gy in 35 fractions: a survey study by the Osaka Urological Tumor Radiotherapy Study Group |
title_full | Analysis of late toxicity associated with external beam radiation therapy for prostate cancer with uniform setting of classical 4-field 70 Gy in 35 fractions: a survey study by the Osaka Urological Tumor Radiotherapy Study Group |
title_fullStr | Analysis of late toxicity associated with external beam radiation therapy for prostate cancer with uniform setting of classical 4-field 70 Gy in 35 fractions: a survey study by the Osaka Urological Tumor Radiotherapy Study Group |
title_full_unstemmed | Analysis of late toxicity associated with external beam radiation therapy for prostate cancer with uniform setting of classical 4-field 70 Gy in 35 fractions: a survey study by the Osaka Urological Tumor Radiotherapy Study Group |
title_short | Analysis of late toxicity associated with external beam radiation therapy for prostate cancer with uniform setting of classical 4-field 70 Gy in 35 fractions: a survey study by the Osaka Urological Tumor Radiotherapy Study Group |
title_sort | analysis of late toxicity associated with external beam radiation therapy for prostate cancer with uniform setting of classical 4-field 70 gy in 35 fractions: a survey study by the osaka urological tumor radiotherapy study group |
topic | Oncology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3534284/ https://www.ncbi.nlm.nih.gov/pubmed/22988284 http://dx.doi.org/10.1093/jrr/rrs083 |
work_keys_str_mv | AT yoshiokayasuo analysisoflatetoxicityassociatedwithexternalbeamradiationtherapyforprostatecancerwithuniformsettingofclassical4field70gyin35fractionsasurveystudybytheosakaurologicaltumorradiotherapystudygroup AT suzukiosamu analysisoflatetoxicityassociatedwithexternalbeamradiationtherapyforprostatecancerwithuniformsettingofclassical4field70gyin35fractionsasurveystudybytheosakaurologicaltumorradiotherapystudygroup AT nishimurakazuo analysisoflatetoxicityassociatedwithexternalbeamradiationtherapyforprostatecancerwithuniformsettingofclassical4field70gyin35fractionsasurveystudybytheosakaurologicaltumorradiotherapystudygroup AT inouehitoshi analysisoflatetoxicityassociatedwithexternalbeamradiationtherapyforprostatecancerwithuniformsettingofclassical4field70gyin35fractionsasurveystudybytheosakaurologicaltumorradiotherapystudygroup AT haratsuneo analysisoflatetoxicityassociatedwithexternalbeamradiationtherapyforprostatecancerwithuniformsettingofclassical4field70gyin35fractionsasurveystudybytheosakaurologicaltumorradiotherapystudygroup AT yoshidaken analysisoflatetoxicityassociatedwithexternalbeamradiationtherapyforprostatecancerwithuniformsettingofclassical4field70gyin35fractionsasurveystudybytheosakaurologicaltumorradiotherapystudygroup AT imaiatsushi analysisoflatetoxicityassociatedwithexternalbeamradiationtherapyforprostatecancerwithuniformsettingofclassical4field70gyin35fractionsasurveystudybytheosakaurologicaltumorradiotherapystudygroup AT tsujimuraakira analysisoflatetoxicityassociatedwithexternalbeamradiationtherapyforprostatecancerwithuniformsettingofclassical4field70gyin35fractionsasurveystudybytheosakaurologicaltumorradiotherapystudygroup AT nonomuranorio analysisoflatetoxicityassociatedwithexternalbeamradiationtherapyforprostatecancerwithuniformsettingofclassical4field70gyin35fractionsasurveystudybytheosakaurologicaltumorradiotherapystudygroup AT ogawakazuhiko analysisoflatetoxicityassociatedwithexternalbeamradiationtherapyforprostatecancerwithuniformsettingofclassical4field70gyin35fractionsasurveystudybytheosakaurologicaltumorradiotherapystudygroup |