Cargando…
Efficacy of repeated 5-fluorouracil needling for failing and failed filtering surgeries based on simple gonioscopic examination
PURPOSE: To evaluate the success rate of a modified bleb needling technique in eyes with previous glaucoma surgery that had elevated intraocular pressure. METHODS: A retrospective study of 24 eyes of 24 patients that underwent repeated bleb needling performed for failing and failed blebs on slit lam...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3534297/ https://www.ncbi.nlm.nih.gov/pubmed/23293510 http://dx.doi.org/10.2147/OPTH.S34848 |
_version_ | 1782475310716944384 |
---|---|
author | Rashad, Mohammad A |
author_facet | Rashad, Mohammad A |
author_sort | Rashad, Mohammad A |
collection | PubMed |
description | PURPOSE: To evaluate the success rate of a modified bleb needling technique in eyes with previous glaucoma surgery that had elevated intraocular pressure. METHODS: A retrospective study of 24 eyes of 24 patients that underwent repeated bleb needling performed for failing and failed blebs on slit lamp with 5-fluorouracil (5-FU) injections on demand. This was performed after gonioscopic examination to define levels of filtration block. RESULTS: There was significant reduction of mean IOP from 36.91 mmHg to 14.73 mmHg at the final follow-up (P < 0.001). The overall success rate was 92%. CONCLUSION: Repeated needling with adjunctive 5-FU proved a highly effective, safe alternative to revive filtration surgery rather than another medication or surgery. |
format | Online Article Text |
id | pubmed-3534297 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-35342972013-01-04 Efficacy of repeated 5-fluorouracil needling for failing and failed filtering surgeries based on simple gonioscopic examination Rashad, Mohammad A Clin Ophthalmol Case Series PURPOSE: To evaluate the success rate of a modified bleb needling technique in eyes with previous glaucoma surgery that had elevated intraocular pressure. METHODS: A retrospective study of 24 eyes of 24 patients that underwent repeated bleb needling performed for failing and failed blebs on slit lamp with 5-fluorouracil (5-FU) injections on demand. This was performed after gonioscopic examination to define levels of filtration block. RESULTS: There was significant reduction of mean IOP from 36.91 mmHg to 14.73 mmHg at the final follow-up (P < 0.001). The overall success rate was 92%. CONCLUSION: Repeated needling with adjunctive 5-FU proved a highly effective, safe alternative to revive filtration surgery rather than another medication or surgery. Dove Medical Press 2013 2012-12-28 /pmc/articles/PMC3534297/ /pubmed/23293510 http://dx.doi.org/10.2147/OPTH.S34848 Text en © 2013 Rashad, publisher and licensee Dove Medical Press Ltd. This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited. |
spellingShingle | Case Series Rashad, Mohammad A Efficacy of repeated 5-fluorouracil needling for failing and failed filtering surgeries based on simple gonioscopic examination |
title | Efficacy of repeated 5-fluorouracil needling for failing and failed filtering surgeries based on simple gonioscopic examination |
title_full | Efficacy of repeated 5-fluorouracil needling for failing and failed filtering surgeries based on simple gonioscopic examination |
title_fullStr | Efficacy of repeated 5-fluorouracil needling for failing and failed filtering surgeries based on simple gonioscopic examination |
title_full_unstemmed | Efficacy of repeated 5-fluorouracil needling for failing and failed filtering surgeries based on simple gonioscopic examination |
title_short | Efficacy of repeated 5-fluorouracil needling for failing and failed filtering surgeries based on simple gonioscopic examination |
title_sort | efficacy of repeated 5-fluorouracil needling for failing and failed filtering surgeries based on simple gonioscopic examination |
topic | Case Series |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3534297/ https://www.ncbi.nlm.nih.gov/pubmed/23293510 http://dx.doi.org/10.2147/OPTH.S34848 |
work_keys_str_mv | AT rashadmohammada efficacyofrepeated5fluorouracilneedlingforfailingandfailedfilteringsurgeriesbasedonsimplegonioscopicexamination |