Factors determining patients’ intentions to use point-of-care testing medical devices for self-monitoring: the case of international normalized ratio self-testing
PURPOSE: To identify factors that determine patients’ intentions to use point-of-care medical devices, ie, portable coagulometer devices for self-testing of the international normalized ratio (INR) required for ongoing monitoring of blood-coagulation intensity among patients on long-term oral antico...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3536357/ https://www.ncbi.nlm.nih.gov/pubmed/23300344 http://dx.doi.org/10.2147/PPA.S38328 |
_version_ | 1782254745604325376 |
---|---|
author | Shah, Syed Ghulam Sarwar Barnett, Julie Kuljis, Jasna Hone, Kate Kaczmarski, Richard |
author_facet | Shah, Syed Ghulam Sarwar Barnett, Julie Kuljis, Jasna Hone, Kate Kaczmarski, Richard |
author_sort | Shah, Syed Ghulam Sarwar |
collection | PubMed |
description | PURPOSE: To identify factors that determine patients’ intentions to use point-of-care medical devices, ie, portable coagulometer devices for self-testing of the international normalized ratio (INR) required for ongoing monitoring of blood-coagulation intensity among patients on long-term oral anticoagulation therapy with vitamin K antagonists, eg, warfarin. METHODS: A cross-sectional study that applied the technology-acceptance model through a self-completed questionnaire, which was administered to a convenience sample of 125 outpatients attending outpatient anticoagulation services at a district general hospital in London, UK. Data were analyzed using descriptive statistics, factor analyses, and structural equation modeling. RESULTS: The participants were mainly male (64%) and aged ≥ 71 years (60%). All these patients were attending the hospital outpatient anticoagulation clinic for INR testing; only two patients were currently using INR self-testing, 84% of patients had no knowledge about INR self-testing using a portable coagulometer device, and 96% of patients were never offered the option of the INR self-testing. A significant structural equation model explaining 79% of the variance in patients’ intentions to use INR self-testing was observed. The significant predictors that directly affected patients’ intention to use INR self-testing were the perception of technology (β = 0.92, P < 0.001), trust in doctor (β = −0.24, P = 0.028), and affordability (β = 0.15, P = 0.016). In addition, the perception of technology was significantly affected by trust in doctor (β = 0.43, P = 0.002), age (β = −0.32, P < 0.001), and affordability (β = 0.23, P = 0.013); thereby, the intention to use INR self-testing was indirectly affected by trust in doctor (β = 0.40), age (β = −0.29), and affordability (β = 0.21) via the perception of technology. CONCLUSION: Patients’ intentions to use portable coagulometers for INR self-testing are affected by patients’ perceptions about the INR testing device, the cost of device, trust in doctors/clinicians, and the age of the patient, which need to be considered prior to any intervention involving INR self-testing by patients. Manufacturers should focus on increasing the affordability of INR testing devices for patients’ self-testing and on the potential role of medical practitioners in supporting use of these medical devices as patients move from hospital to home testing. |
format | Online Article Text |
id | pubmed-3536357 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-35363572013-01-08 Factors determining patients’ intentions to use point-of-care testing medical devices for self-monitoring: the case of international normalized ratio self-testing Shah, Syed Ghulam Sarwar Barnett, Julie Kuljis, Jasna Hone, Kate Kaczmarski, Richard Patient Prefer Adherence Original Research PURPOSE: To identify factors that determine patients’ intentions to use point-of-care medical devices, ie, portable coagulometer devices for self-testing of the international normalized ratio (INR) required for ongoing monitoring of blood-coagulation intensity among patients on long-term oral anticoagulation therapy with vitamin K antagonists, eg, warfarin. METHODS: A cross-sectional study that applied the technology-acceptance model through a self-completed questionnaire, which was administered to a convenience sample of 125 outpatients attending outpatient anticoagulation services at a district general hospital in London, UK. Data were analyzed using descriptive statistics, factor analyses, and structural equation modeling. RESULTS: The participants were mainly male (64%) and aged ≥ 71 years (60%). All these patients were attending the hospital outpatient anticoagulation clinic for INR testing; only two patients were currently using INR self-testing, 84% of patients had no knowledge about INR self-testing using a portable coagulometer device, and 96% of patients were never offered the option of the INR self-testing. A significant structural equation model explaining 79% of the variance in patients’ intentions to use INR self-testing was observed. The significant predictors that directly affected patients’ intention to use INR self-testing were the perception of technology (β = 0.92, P < 0.001), trust in doctor (β = −0.24, P = 0.028), and affordability (β = 0.15, P = 0.016). In addition, the perception of technology was significantly affected by trust in doctor (β = 0.43, P = 0.002), age (β = −0.32, P < 0.001), and affordability (β = 0.23, P = 0.013); thereby, the intention to use INR self-testing was indirectly affected by trust in doctor (β = 0.40), age (β = −0.29), and affordability (β = 0.21) via the perception of technology. CONCLUSION: Patients’ intentions to use portable coagulometers for INR self-testing are affected by patients’ perceptions about the INR testing device, the cost of device, trust in doctors/clinicians, and the age of the patient, which need to be considered prior to any intervention involving INR self-testing by patients. Manufacturers should focus on increasing the affordability of INR testing devices for patients’ self-testing and on the potential role of medical practitioners in supporting use of these medical devices as patients move from hospital to home testing. Dove Medical Press 2012-12-28 /pmc/articles/PMC3536357/ /pubmed/23300344 http://dx.doi.org/10.2147/PPA.S38328 Text en © 2013 Shah et al, publisher and licensee Dove Medical Press Ltd. This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited. |
spellingShingle | Original Research Shah, Syed Ghulam Sarwar Barnett, Julie Kuljis, Jasna Hone, Kate Kaczmarski, Richard Factors determining patients’ intentions to use point-of-care testing medical devices for self-monitoring: the case of international normalized ratio self-testing |
title | Factors determining patients’ intentions to use point-of-care testing medical devices for self-monitoring: the case of international normalized ratio self-testing |
title_full | Factors determining patients’ intentions to use point-of-care testing medical devices for self-monitoring: the case of international normalized ratio self-testing |
title_fullStr | Factors determining patients’ intentions to use point-of-care testing medical devices for self-monitoring: the case of international normalized ratio self-testing |
title_full_unstemmed | Factors determining patients’ intentions to use point-of-care testing medical devices for self-monitoring: the case of international normalized ratio self-testing |
title_short | Factors determining patients’ intentions to use point-of-care testing medical devices for self-monitoring: the case of international normalized ratio self-testing |
title_sort | factors determining patients’ intentions to use point-of-care testing medical devices for self-monitoring: the case of international normalized ratio self-testing |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3536357/ https://www.ncbi.nlm.nih.gov/pubmed/23300344 http://dx.doi.org/10.2147/PPA.S38328 |
work_keys_str_mv | AT shahsyedghulamsarwar factorsdeterminingpatientsintentionstousepointofcaretestingmedicaldevicesforselfmonitoringthecaseofinternationalnormalizedratioselftesting AT barnettjulie factorsdeterminingpatientsintentionstousepointofcaretestingmedicaldevicesforselfmonitoringthecaseofinternationalnormalizedratioselftesting AT kuljisjasna factorsdeterminingpatientsintentionstousepointofcaretestingmedicaldevicesforselfmonitoringthecaseofinternationalnormalizedratioselftesting AT honekate factorsdeterminingpatientsintentionstousepointofcaretestingmedicaldevicesforselfmonitoringthecaseofinternationalnormalizedratioselftesting AT kaczmarskirichard factorsdeterminingpatientsintentionstousepointofcaretestingmedicaldevicesforselfmonitoringthecaseofinternationalnormalizedratioselftesting |