Cargando…
Investigations concerning the application of the cross-correlation method in cardiac output measurements
BACKGROUND: In spite of numerous non-invasive examinations the “gold clinical standard” of cardiac output measurements is the invasive pulmonary artery catheterization by means of the Swan-Ganz catheter and the application of the thermodilution method to estimate the blood flow. The results obtained...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3537564/ https://www.ncbi.nlm.nih.gov/pubmed/22607380 http://dx.doi.org/10.1186/1475-925X-11-24 |
_version_ | 1782254869812346880 |
---|---|
author | Gawlikowski, Maciej Pustelny, Tadeusz |
author_facet | Gawlikowski, Maciej Pustelny, Tadeusz |
author_sort | Gawlikowski, Maciej |
collection | PubMed |
description | BACKGROUND: In spite of numerous non-invasive examinations the “gold clinical standard” of cardiac output measurements is the invasive pulmonary artery catheterization by means of the Swan-Ganz catheter and the application of the thermodilution method to estimate the blood flow. The results obtained by means of thermodilution are sensitive to many physical and biological disturbances. The unreliability of this method amounts to 20-45% and depends on the given variant of the method. Therefore some other method, more accurate and resistant to disturbances, was looked for. This paper presents a new approach to cardiac output measurements, based on cross-correlation signal analysis. The goal of investigations was to verify experimentally the application of the cross-correlation method of cardiac output measurements. RESULTS: In 99.2% of the examined cases the extreme of the cross-correlation function was easy to be estimated by numerical algorithms. In 0,8% of the remaining cases (with a plateau region adjacent to the maximum point) numerical detection of the extreme was inaccurate. The typical unreliability of the investigated method amounted o 5.1% (9.8% in the worst case). Investigations performed on a physical model revealed that the unreliability of cardiac output measurements by means of the cross-correlation method is 3–5 times better than in the case of thermodilution. CONCLUSIONS: The performed investigations and theoretical analysis have shown, that the cross-correlation method may be applied in cardiac output measurements. This kind of measurements seems to be more accurate and disturbance-resistant than clinically applied thermodilution. |
format | Online Article Text |
id | pubmed-3537564 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-35375642013-01-10 Investigations concerning the application of the cross-correlation method in cardiac output measurements Gawlikowski, Maciej Pustelny, Tadeusz Biomed Eng Online Research BACKGROUND: In spite of numerous non-invasive examinations the “gold clinical standard” of cardiac output measurements is the invasive pulmonary artery catheterization by means of the Swan-Ganz catheter and the application of the thermodilution method to estimate the blood flow. The results obtained by means of thermodilution are sensitive to many physical and biological disturbances. The unreliability of this method amounts to 20-45% and depends on the given variant of the method. Therefore some other method, more accurate and resistant to disturbances, was looked for. This paper presents a new approach to cardiac output measurements, based on cross-correlation signal analysis. The goal of investigations was to verify experimentally the application of the cross-correlation method of cardiac output measurements. RESULTS: In 99.2% of the examined cases the extreme of the cross-correlation function was easy to be estimated by numerical algorithms. In 0,8% of the remaining cases (with a plateau region adjacent to the maximum point) numerical detection of the extreme was inaccurate. The typical unreliability of the investigated method amounted o 5.1% (9.8% in the worst case). Investigations performed on a physical model revealed that the unreliability of cardiac output measurements by means of the cross-correlation method is 3–5 times better than in the case of thermodilution. CONCLUSIONS: The performed investigations and theoretical analysis have shown, that the cross-correlation method may be applied in cardiac output measurements. This kind of measurements seems to be more accurate and disturbance-resistant than clinically applied thermodilution. BioMed Central 2012-05-20 /pmc/articles/PMC3537564/ /pubmed/22607380 http://dx.doi.org/10.1186/1475-925X-11-24 Text en Copyright ©2012 Gawlikowski and Pustelny; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Gawlikowski, Maciej Pustelny, Tadeusz Investigations concerning the application of the cross-correlation method in cardiac output measurements |
title | Investigations concerning the application of the cross-correlation method in cardiac output measurements |
title_full | Investigations concerning the application of the cross-correlation method in cardiac output measurements |
title_fullStr | Investigations concerning the application of the cross-correlation method in cardiac output measurements |
title_full_unstemmed | Investigations concerning the application of the cross-correlation method in cardiac output measurements |
title_short | Investigations concerning the application of the cross-correlation method in cardiac output measurements |
title_sort | investigations concerning the application of the cross-correlation method in cardiac output measurements |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3537564/ https://www.ncbi.nlm.nih.gov/pubmed/22607380 http://dx.doi.org/10.1186/1475-925X-11-24 |
work_keys_str_mv | AT gawlikowskimaciej investigationsconcerningtheapplicationofthecrosscorrelationmethodincardiacoutputmeasurements AT pustelnytadeusz investigationsconcerningtheapplicationofthecrosscorrelationmethodincardiacoutputmeasurements |