Cargando…

Investigations concerning the application of the cross-correlation method in cardiac output measurements

BACKGROUND: In spite of numerous non-invasive examinations the “gold clinical standard” of cardiac output measurements is the invasive pulmonary artery catheterization by means of the Swan-Ganz catheter and the application of the thermodilution method to estimate the blood flow. The results obtained...

Descripción completa

Detalles Bibliográficos
Autores principales: Gawlikowski, Maciej, Pustelny, Tadeusz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3537564/
https://www.ncbi.nlm.nih.gov/pubmed/22607380
http://dx.doi.org/10.1186/1475-925X-11-24
_version_ 1782254869812346880
author Gawlikowski, Maciej
Pustelny, Tadeusz
author_facet Gawlikowski, Maciej
Pustelny, Tadeusz
author_sort Gawlikowski, Maciej
collection PubMed
description BACKGROUND: In spite of numerous non-invasive examinations the “gold clinical standard” of cardiac output measurements is the invasive pulmonary artery catheterization by means of the Swan-Ganz catheter and the application of the thermodilution method to estimate the blood flow. The results obtained by means of thermodilution are sensitive to many physical and biological disturbances. The unreliability of this method amounts to 20-45% and depends on the given variant of the method. Therefore some other method, more accurate and resistant to disturbances, was looked for. This paper presents a new approach to cardiac output measurements, based on cross-correlation signal analysis. The goal of investigations was to verify experimentally the application of the cross-correlation method of cardiac output measurements. RESULTS: In 99.2% of the examined cases the extreme of the cross-correlation function was easy to be estimated by numerical algorithms. In 0,8% of the remaining cases (with a plateau region adjacent to the maximum point) numerical detection of the extreme was inaccurate. The typical unreliability of the investigated method amounted o 5.1% (9.8% in the worst case). Investigations performed on a physical model revealed that the unreliability of cardiac output measurements by means of the cross-correlation method is 3–5 times better than in the case of thermodilution. CONCLUSIONS: The performed investigations and theoretical analysis have shown, that the cross-correlation method may be applied in cardiac output measurements. This kind of measurements seems to be more accurate and disturbance-resistant than clinically applied thermodilution.
format Online
Article
Text
id pubmed-3537564
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-35375642013-01-10 Investigations concerning the application of the cross-correlation method in cardiac output measurements Gawlikowski, Maciej Pustelny, Tadeusz Biomed Eng Online Research BACKGROUND: In spite of numerous non-invasive examinations the “gold clinical standard” of cardiac output measurements is the invasive pulmonary artery catheterization by means of the Swan-Ganz catheter and the application of the thermodilution method to estimate the blood flow. The results obtained by means of thermodilution are sensitive to many physical and biological disturbances. The unreliability of this method amounts to 20-45% and depends on the given variant of the method. Therefore some other method, more accurate and resistant to disturbances, was looked for. This paper presents a new approach to cardiac output measurements, based on cross-correlation signal analysis. The goal of investigations was to verify experimentally the application of the cross-correlation method of cardiac output measurements. RESULTS: In 99.2% of the examined cases the extreme of the cross-correlation function was easy to be estimated by numerical algorithms. In 0,8% of the remaining cases (with a plateau region adjacent to the maximum point) numerical detection of the extreme was inaccurate. The typical unreliability of the investigated method amounted o 5.1% (9.8% in the worst case). Investigations performed on a physical model revealed that the unreliability of cardiac output measurements by means of the cross-correlation method is 3–5 times better than in the case of thermodilution. CONCLUSIONS: The performed investigations and theoretical analysis have shown, that the cross-correlation method may be applied in cardiac output measurements. This kind of measurements seems to be more accurate and disturbance-resistant than clinically applied thermodilution. BioMed Central 2012-05-20 /pmc/articles/PMC3537564/ /pubmed/22607380 http://dx.doi.org/10.1186/1475-925X-11-24 Text en Copyright ©2012 Gawlikowski and Pustelny; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Gawlikowski, Maciej
Pustelny, Tadeusz
Investigations concerning the application of the cross-correlation method in cardiac output measurements
title Investigations concerning the application of the cross-correlation method in cardiac output measurements
title_full Investigations concerning the application of the cross-correlation method in cardiac output measurements
title_fullStr Investigations concerning the application of the cross-correlation method in cardiac output measurements
title_full_unstemmed Investigations concerning the application of the cross-correlation method in cardiac output measurements
title_short Investigations concerning the application of the cross-correlation method in cardiac output measurements
title_sort investigations concerning the application of the cross-correlation method in cardiac output measurements
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3537564/
https://www.ncbi.nlm.nih.gov/pubmed/22607380
http://dx.doi.org/10.1186/1475-925X-11-24
work_keys_str_mv AT gawlikowskimaciej investigationsconcerningtheapplicationofthecrosscorrelationmethodincardiacoutputmeasurements
AT pustelnytadeusz investigationsconcerningtheapplicationofthecrosscorrelationmethodincardiacoutputmeasurements